• Title/Summary/Keyword: bc12

Search Result 337, Processing Time 0.03 seconds

Study on architecture of u-number system and network (BcN에서 유비쿼터스주소 체계 및 네트워크구조 연구)

  • Chung, Hee-Chang;Lee, Yeong-Ro
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.12
    • /
    • pp.71-76
    • /
    • 2005
  • The 070-VOIP service were began to support system of E.164 and an IP address service. The address system was proposed how an convergence of E.164 address system was worked with an EPC and an IP address to the multimedia convergence service within the integration of wireless and wireline. In future, it was presented the way that the end user could use an integrated address system to be based on E.164 in BcN networks. An expansibility will be easy to all things are put into in knowledge that u- address system use an integrated address system to the basis of E.164 system.

Intravenous Fluid Selection for Unruptured Intracranial Aneurysm Clipping : Balanced Crystalloid versus Normal Saline

  • Kang, Jian;Song, Young Joo;Jeon, Sujeong;Lee, Junghwa;Lee, Eunsook;Lee, Ju-Yeun;Lee, Euni;Bang, Jae Seung;Lee, Si Un;Han, Moon-Ku;Oh, Chang Wan;Kim, Tackeun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.534-542
    • /
    • 2021
  • Objective : While balanced crystalloid (BC) could be a relevant fluid regimen with buffer system compared with normal saline (NS), there have been no studies on the optimal fluid for surgery of an unruptured intracranial aneurysm (UIA). This study aimed to compare the effects of fluid regimens between NS and BC on the metabolic and clinical outcomes of patients who underwent surgery for UIA. Methods : This study was designed as a propensity score matched retrospective comparative study and included adult patients who underwent UIA clipping. Patient groups were categorized as NS and BC groups based on the types of pre-operative fluid and the amount of fluid administered during surgery. The primary outcomes were defined as electrolyte imbalance and acidosis immediately after surgery. The secondary outcomes were the length of stay in the intensive care unit (ICU) and duration from the end of the operation to extubation. Results : A total of 586 patients were enrolled in this study, with each of 293 patients assigned to the NS and BC groups, respectively. Immediately after surgery, serum chloride levels were significantly higher in the NS group. Compared to the NS group, the BC group had lower incidence rates of acidemia (6.5% vs. 11.6%, p=0.043) and metabolic acidosis (0.7% vs. 4.4%, p=0.007). As compared to NS group, BC group had significantly shorter duration from the end of the operation to extubation (250±824 vs. 122±372 minutes, p=0.016) and length of stay in ICU (1.37±1.11 vs. 1.12±0.61 days, p=0.001). Throughout multivariable analysis, use of BC was found to be significant factor for favorable post-operative results. Conclusion : This study showed that the patients who received BC during UIA clipping had lower incidence of metabolic acidosis, earlier extubation and shorter ICU stay compared to those who received NS. Therefore, using BC as a peri-operative fluid can be recommended for patients who undergo surgery for UIA.

Implementation of Wideband SSM with Excellent Sideband and Carrier Suppression (우수한 측파대 및 반송파 억압을 갖는 광대역 단측파대 믹서의 구현)

  • Kim, In-Seon;Park, Young-Ju;Kim, Jang-Pyo;Jeon, Jeong-Il;Kim, Moo-Hoi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1097-1106
    • /
    • 2011
  • In this paper, we present design method of wideband single-sideband mixer(SSM) with excellent sideband suppression and carrier suppression. We proposed SSM with 4-band split structure for uniform output flatness. From circuit simulation of this structure using Microwave OfficeTM, we got satisfactory results. We realized a SSM based on this results, then we experimented. The measured results show excellent agreements with the simulated results. We compared with two SSM's(target SSM(M Co. SM0218LC1CDC SSM) and our SSM) as well. The presented SSM is 3.35 times bigger, but sideband suppression is 3 dBc better and carrier suppression is 8 dBc better than those of comparative SSM, respectively.

Design of Voltage Controlled Oscillator with High Reliability and Low Phase Noise (고신뢰성과 저위상잡음을 갖는 전압제어 발진기의 설계 및 제작)

  • Ryu Keun-Kwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.13-19
    • /
    • 2004
  • The VCO(Voltage Controlled Oscillator) with low phase noise and high reliability is implemented using nonlinear design, and its phase noise characteristics are compared with that of Lesson's equation. The microstripline coupled with dielectric resonator is realized as a high impedance inverter to improve the phase noise, and the qualify factor of resonator circuit can be transferred to active device with the enhanced the loaded quality factor. The worst case and part stress analyses are achieved to obtain the high reliability of VCO. The developed VCO has the oscillating tuning factor of 0.56MHz/V for the control voltage range of 0$\~$12V This VCO requires the DC power of 160mW. The phase noise characteristics exhibit good performances of -96.51dBc/Hz @ 10KHz and -116.3dBc/Hz @ 100KHz, respectively. And, the output power of 7.33 dBm is measured.

  • PDF

Design and Implementation of an L-Band Single-Sideband Mixer with CMOS Switches and C-Band CMOS QVCO (CMOS 스위치부를 갖는 L-대역 단측파대역 주파수 혼합기 및 C-대역 QVCO 설계 및 제작)

  • Lee, Jung-Woo;Kim, Nam-Yoon;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.691-698
    • /
    • 2014
  • An L-band single side band(SSB) mixer with CMOS switches and a C-band quadrature voltage-controlled oscillator(QVCO) have been developed using the TowerJazz 0.18-um RFCMOS process. The SSB mixer exhibits a conversion gain of 6.6 ~ 7.5 dB with a 70-dBc image rejection ratio and 65-dBc port isolation. The oscillation frequency range of the QVCO is 6.2 ~ 6.7 GHz with an output power of 4~6 dBm. For measurement, 1.8 V supply voltage is used while drawing 36 mA for the mixer and 23 mA for the QVCO.

Design and Fabrication of Voltage Control Oscillator at X-band using Dielectric Resonator (유전체 공진기를 이용한 X-band 전압제어 발진기 설계 및 제작)

  • Han, Sok-Kyun;Choi, Byung-Ha
    • Journal of Navigation and Port Research
    • /
    • v.27 no.5
    • /
    • pp.513-517
    • /
    • 2003
  • In this paper, a VCDRO(Voltage Control Dielectric Resonator Oscillator} applied to X-band as stable source is implementea and constructed with a MESFET for low noise, a dielectric resonator of high frequency selectivity and high Q varactor diode to obtain a good phase noise performance and stable sweep characteristics. The designed circuits is simulated through the harmonic balance simulation technique to provide the optimum performance. The measured results of a fabricated VCDRO show that output is 2.22dBm at 12.05GHz. harmonic suppression -30dBc. phase noise -130dBc at 100kHz offset. and sweep range of varactor diode $\pm$18.7MHz. respectively. This oscillator will be available to X-band application.

A Linearity Improved Power Amplifier using Bandpass Filter Based on Composite Right-/Left-Handed Structure (CRLH 구조의 대역통과여파기를 이용한 전력증폭기의 선형성 개선에 관한 연구)

  • Kim, Hyoung-Jun;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, we present a bandpass filter (BPF) based on composite right-/left-handed (CRLH) structure for improving the linearity of the power amplifier. The proposed BPF consist of the inter-digit signal line on the top plane and the complementary split ring resonator (CSRR) on the bottom plane, respectively. The insertion loss is minimized at operation frequency and the 2nd harmonic is suppressed by the bandpass filter using the CRLH structure, respectively. The output power of 33 dBm, the 2nd harmonic of -53.527 dBc, 3rd inter-modulation distortion of -36.16 dBc was obtained at 2.14 GHz, respectively. Compared with the reference power amplifier, the 2nd harmonic of 16 dB and 3rd inter-modulation distortion of 12 dB have been improved at 2.14 GHz, respectively.

Implementation of RF Frequency Synthesizer for IEEE 802.15.4g SUN System (IEEE 802.15.4g SUN 시스템용 RF 주파수 합성기의 구현)

  • Kim, Dong-Shik;Yoon, Won-Sang;Chai, Sang-Hoon;Kang, Ho-Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.57-63
    • /
    • 2016
  • This paper describes implementation of the RF frequency synthesizer with $0.18{\mu}m$ silicon CMOS technology being used as an application of the IEEE802.15.4g SUN sensor node transceiver modules. Design of the each module like VCO, prescaler, 1/N divider, ${\Delta}-{\Sigma}$ modulator, and common circuits of the PLL has been optimized to obtain high speed and low noise performance. Especially, the VCO has been designed with NP core structure and 13 steps cap-bank to get high speed, low noise, and wide band tuning range. The output frequencies of the implemented synthesizer is 1483MHz~2017MHz, the phase noise of the synthesizer is -98.63dBc/Hz at 100KHz offset and -122.05dBc/Hz at 1MHz offset.

Implementation of Voltage Control Dielectric Resonator Oscillator for FMCW Radar (FMCW 레이더용 전압제어 유전체 발진기의 구현)

  • 안용복;박창현;김장구;조현식;강상록;한석균;최병하
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.398-402
    • /
    • 2003
  • In this paper, a VCDRO(Voltage Control Dielectric Resonator Oscillator) applied to FMCW(Frequency Modulated Continuous Wave)Radar as stable source is implemented and constructed with a MESFET for low noise, a dielectric resonator of high frequency selectivity, and high Q varator diode to obtain a good phase noise performance and stable sweep characteristics. The designed circuits is simulated thrash harmonic balance simulation technique to provide the optimum performance. The measured result of a fabricated VCDRO shows that output is 2.22dBm at 12.05GHz, harmonic suppression -30dBc, phase noise -130dBc at 100kHz offset, and sweep range of varator diode $\pm$18.7MHz, respectively. This oscillator will be available to FMCW Radar.

  • PDF

Factors Delaying Presentation of Sudanese Breast Cancer Patients: an Analysis Using Andersen's Model

  • Salih, Alaaddin M;Alfaki, Musab M;Alam-Elhuda, Dafallah M;Nouradyem, Momin M
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2105-2110
    • /
    • 2016
  • Purpose: A multicenter, observational, cross-sectional study was conducted to assess factors delaying presentation of breast cancer cases. Materials and Methods: Data were collected from a pair of highly specialized referral centers, both located in the center of the Sudanese capital, Khartoum. For a total of 153 eligible respondents, durations of delay, clinicodemographic factors and reasons of referral were collected from our respondents through self-administered questionnaires. Logistic regression analysis and ANOVA were used to test the relation between periods of delay and different factors. Odd ratios (OR's) and their correspondent Confidence intervals (95% CI's). Delay periods were studied with Andersen's model. Results: The average duration of delay in our study was 11.9 (${\pm}11.2$) months. Only a quarter of our patients presented early within the first 3 months after onset of their symptoms. About 47.7% arrived later during the course of the first year, while it took beyond that for the last 27% to come. A prior diagnosis of BC was the only predictor of early presentation (for 3-12 months OR=9.6 (p<0.00), 95% CI 9.55-9.75; for >12 months OR=9.3 (p<0.00), 95% CI 9.33-9.33). Out of the 12 different reasons for delay given by our respondents, none showed a significant difference between patients presenting early or late. Financial incapacity (17.5%), ignorance about BC (14.3), and misinterpreting symptoms (12.7%) were the top three whys of delay. Conclusions: Our findings support existence of a non-uniform pattern of delay among Sudanese BC patients. Changing currently adopted awareness elevating strategies into much more inclusive approaches is strongly recommended.