• 제목/요약/키워드: basic performance test

검색결과 1,005건 처리시간 0.024초

스크류유량계 개발에서의 역공학 및 성능평가에 관한 연구 (A Study on the Reverse Engineering and Performance Test in the Development of Screw Flowmeter)

  • 황종대;정종윤;이상렬;정윤교
    • 한국기계가공학회지
    • /
    • 제4권2호
    • /
    • pp.24-30
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF

역공학 기술을 이용한 스크류 유량계 개발 및 성능평가에 관한 연구 (Study on the Development and Performance Test of Screw Flowmeter using Reverse Engineering)

  • 김형일;황종대;정윤교
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.601-606
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF

스크류유량계 개발에 있어서의 역공학 및 성능평가에 관한 연구 (Study on the reverse engineering and performance test in the development of screw flowmeter)

  • 김종윤;황종대;이상열;정윤교
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.132-137
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw type flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flow meter.

  • PDF

RC 슬래브 교량의 현장재하시험을 통한 안전성 평가 (Safety Evaluation through Field Load Test of RC Slab Bridge)

  • 조한민
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.

BASIC 언어를 사용한 Hill-Sliding 무감독 분류법 Algorithm 개발 (Development of the Hill-Sliding Clustering Algorithm Using BASIC Language)

  • 鄭夢炫;崔圭弘;朴景允;Park, J.Kyoungyoon
    • 대한원격탐사학회지
    • /
    • 제1권1호
    • /
    • pp.89-97
    • /
    • 1985
  • Hill-Sliding Clustering이라는 다변량 자료의 무감독 분류 방법을 Apple II personal computer의 BASIC언어를 사용한 Algorithm으로 개발하였다. 이 Algorithm으로 다변량 multimode를 갖는 정규 분포 자료에서 사전 지식없이 자료를 집단화하여 구분해 낼 수 있게 되 었다. 한국 연안 지역의 Landsat(지구 자원 탐사 위성)의 다중, Spectrum 영상 자료에 적용한 시 험 결과, 매우 고무적 결론을 얻었다.

The Accuracy of Glasgow Coma Scale Knowledge and Performance among Vietnamese Nurses

  • Hien, Nguyen Thi;Chae, Sun-Mi
    • Perspectives in Nursing Science
    • /
    • 제8권1호
    • /
    • pp.54-61
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the accuracy of Glasgow Coma Scale (GCS) knowledge and performance among Vietnamese nurses. Methods: A cross-sectional descriptive study was conducted using a questionnaire pertaining to the nurses' knowledge of GCS and a structured evaluation tool to measure the accuracy of their GCS scores. A total of 94 Vietnamese nurses participated in this study, all from a general hospital in Ho Chi Minh City, Vietnam. Data were analyzed by conducting a t-test, a $x^2$ test, and ANOVA. Results: This study found that the vast majority of the nurses (>90%) responded correctly to questions regarding their GCS basic knowledge; however, 52.1% of the nurses answered incorrectly questions related to clinical scenarios requiring the application of the basic knowledge. Regarding the GCS performance, the nurses demonstrated acceptable accuracy rates for each component of GCS, but those who scored well in all three components accounted for only 42.6% of the subject group. These findings indicate that the Vietnamese nurses are not able to integrate their GCS knowledge into actual practice as measured by the accuracy of GCS scoring. Conclusion: This study suggests that new educational strategies should be developed for the Vietnamese nurses to improve their performance on accurate GCS scoring based on theoretical knowledge.

  • PDF

The Performance Evaluation of R407C and R410B in a Residential Window Air-Conditioner

  • Kim, Man-Hoe;Shin, Jeong-Seob;Kim, Kwon-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.148-157
    • /
    • 1998
  • This study presents test results of a residential window air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests has been carried out for the basic and liquid-suction heat exchange cycles in a psychometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-suction heat exchange cycle was also considered to improve the system performance. Test results were compared with those for the basic R22 system. The modified system with a liquid-suction heat exchanger increased cooling capacity and energy efficiency by up to 5%.

  • PDF

학습 장애아 진단 도구로 기초 학습 기능 검사의 유용성에 관한 연구 (A USEFULNESS OF KEDI-INDIVIDUAL BASIC LEARNING SKILLS TEST AS A DIAGNOSTIC TOOL OF LEARNING DISORDERS)

  • 김지혜;이명주;홍성도;김승태
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제8권1호
    • /
    • pp.101-112
    • /
    • 1997
  • 본 연구의 목적은 학습 장애를 진단하는데 있어 성취도 검사인 기초학습기능검사의 유용성을 살펴보는 것이다. 학습 장애 집단은 두 유형으로 나누어 언어적 학습 장애 집단(VLD:Verbal Learning Disorder) 34명, 비언어적 학습 장애 집단(NVLD:Nonverbal Learning Disorder) 14명으로 총 48명으로 구성되었으며, 비교 집단으로는 Dysthymia 집단 11명, 정상아 20명을 대상으로 지능 검사 및 기초학습 기능검사의 수행을 비교하였다. 지능 검사에서 VLD집단은 어휘력 및 언어를 통한 학습 과제, 언어-청각적인 주의과제에서 의미있는 저하를 나타내었고, NVLD 집단은 시-지각의 정확도, 정신-운동성 기능의 협응 속도, 시각-공각적인 조직력 등 동작성 기능 전반에 걸쳐 비효율성을 나타내었다. 기초학습기능검사에서는 VLD 집단은 음운 부호화과제, 셈하기 능력, 단어 재인 과제에서 의미있는 저하를 나타내었다. 또한 지능 검사의 소검사들에 기초학습기능검사의 소검사들을 포함하여 판별 분석을 한 결과, 기초학습기능검사를 포함시키지 않은 경우보다 판별율이 높아졌을 뿐 아니라, VLD집단을 유의미하게 판별해 주는 판별 함수를 도출하였다. 각 소검사들의 속성을 분석하기 위하여 요인 분석을 실시하였으며 이를 통하여 소검사들을 유목화하였으며 마지막으로 현 논문의 제한점 및 기초학습기능검사의 제한점을 논의하였다.

  • PDF

송전용 자기재 애자의 성능평가 및 가속열화시험 (Study on Performance and Aging Test of Porcelain Insulators for Transmission Line)

  • 한세원;조한구;박기호;이동일;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

A Study on the Impact Safety Test for Wheelchairs

  • Han, Jung-Soo;Choi, Jae-Bong
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.30-34
    • /
    • 2008
  • For the purpose of establishing basic design standards for the manufacture of wheelchairs, a dummy for an ISO-standard wheelchair was modeled for use with a manufactured wheelchair, and the safety and performance of the wheelchair were examined through numerical simulations.