• Title/Summary/Keyword: base concrete

Search Result 694, Processing Time 0.025 seconds

Bond Strength of Latex-Modified Concrete (라텍스 개질 콘크리트의 부착강도 특성)

  • 윤경구;이남주;장흥균;심도식;김경진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.647-652
    • /
    • 2000
  • The bond strength of latex-modified concrete to normal portland cement concrete measured with direct pull-out test. Using $250\times1100\times1400$mm concrete slab as the base concrete, an overlay of the latex-modified concrete is applied and cured similar to bridge deck and then tested in direct pull-out. The test results not only give values of the bond strength of the overlay tested but also clearly indicate whether the failure is in the bond interface or the materials tested.

  • PDF

A Study for the Application of High-Strength Concrete (고강도 콘크리트의 실용화를 위한 연구)

  • 이장화;유영찬;민병렬;김긍환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.140-145
    • /
    • 1991
  • Tests were conducted to get a mix proportioning of high strength concrete between σ28 and (C/W) using low quality materials easily purchased in situ. Superplasticizer was used as a chemical admixture to compensate low slump of base concrete keeping it up about 15±2㎝. General material properties such as modulus of elasticity, poisson's ratio, unit weight and stress-strain characteristic of high strength concrete were obtained. Test results show that mix proportioning of high strength concrete proposed in this paper have reasonable validity and these can be used as a design criteria in high strength concrete construction.

  • PDF

Numerical and experimental behavior of moment concrete frame retrofitted with TADAS metal yielding damper under lateral loading

  • Reza Nazeran;Ali Hemmati;Hasan Haji Kazemi
    • Structural Engineering and Mechanics
    • /
    • v.89 no.5
    • /
    • pp.507-524
    • /
    • 2024
  • Since the cost of reconstruction is very high and the structure may have been damaged by an earthquake, we must retrofit the structure. Therefore, the importance of studying this issue is very high in order to achieve the desired resistance against the regulations. The present study involved the numerical and experimental analysis of nine concrete frames, consisting of three concrete frames, three concrete frames with bracing, and three concrete frames with a TADAS damper. The purpose of this study is to strengthen the damaged concrete frame using braces and TADAS dampers. Observations were made of the frames as they were subjected to controlled displacement. Also, ABAQUS software was used to compare numerical and experimental results. According to the results, the software was sufficiently capable of modeling the studied frames. Additionally, a parametric study was conducted on the thickness and number of bending plates. Thickness increases from 8 mm to 12 mm, 8 mm to 15 mm, and 8 mm to 20 mm, increasing the base shear by about 6.7%, 11.1%, and 25%, respectively. Furthermore, increasing the number of plates from 4 to 5, 4 to 6, and 4 to 7 increased base shears by about 4.5%, 8.4%, and 14%, respectively.

Bearing Strength of Steel Baseplate under Eccentric Loads (편심축력(偏心軸力)을 받는 철골구조(鐵骨構造) 주각부(柱脚部)의 지압강도(支壓强度))

  • Choi, Mun Sik;Min, Byung Yeol
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.683-691
    • /
    • 2003
  • Recently, the steel has been increaseingly used as an integrated part of high-rise buildings, which often composed of steel structures, steel reinforced concrete structures and composite structures. The steel base is designed to transfer the stresses induced from steel column to the reinforced concrete footing through the base plate. However, in the design of steel structures and steel reinforced concrete structure, it is generally difficult to evaluate the bearing strength of the steel base subjected to large axial force. Furthermore, the material used in steel base is quite different from those used in other connections and a load transferring mechanism of steel base is very complicated in nature. Therefore, a special attention must be placed in design and construction of steel base. In generally, the bearing strength test and research of the steel base subjected to concentrated load are carried out. But, in the design of the structures, uniaxial eccentric load is loaded to the steel base of the steel structures. In this research, the bearing strength and the me of failure considering eccentric loads and eccentric length, were experimented when eccentric load is loaded to the steel base of steel structures. Based on the test results, a basic design reference is suggested for a reasonable design of steel structures, steel reinforced concrete structures and composite structures.

Structural Safety Assessment of a Concrete-filled Base Frame Supporting a Motor for Centrifugal Compressor Drives (원심식 압축기 구동용 모터 베이스 프레임의 콘크리트 타설에 따른 구조안전성 평가)

  • Kim, Min-Jin;Lee, Jae-Hoon;Han, Jeong-Sam
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, we perform structural analysis for a base frame which is used to support a motor for large centrifugal compressor drives and a safety assessment according to the concrete placement. First, the structural analysis about four loading conditions for the motor base frame was conducted and the structural safety was evaluated through both the maximum distortion energy theory and Mohr-Coulomb theory. It was possible to perform a more reasonable safety evaluation against local stresses occurring at the discontinuous portion of the fragile structural members by applying the safety assessment through ASME VIII Div. 2. In addition, the motor base frames with and without the internal concrete placement were quantitatively compared by the structural analysis and safety evaluation using ASME code and it was found to improve the structural integrity due to the concrete placement.

Experimental and numerical investigation on exposed RCFST column-base Joint

  • Ben, Mou;Xingchen, Yan;Qiyun, Qiao;Wanqiu, Zhou
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.749-766
    • /
    • 2022
  • This paper investigates the seismic performance of exposed RCFST column-base joints, in which the high-strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width-thickness ratio (D/t), axial force ratio (n), shear-span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column-base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column-base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.

Analysis and design of demountable circular CFST column-base connections

  • Li, Dongxu;Wang, Jia;Uy, Brian;Aslani, Farhad;Patel, Vipul
    • Steel and Composite Structures
    • /
    • v.28 no.5
    • /
    • pp.559-571
    • /
    • 2018
  • In current engineering practice, circular concrete-filled steel tubular (CFST) columns have been used as effective structural components due to their significant structural and economic benefits. To apply these structural components into steel-concrete composite moment resisting frames, increasing number of research into the column-base connections of circular CFST columns have been found. However, most of the previous research focused on the strength, rigidity and seismic resisting performance of the circular CFST column-base connections. The present paper attempts to investigate the demountability of bolted circular CFST column-base connections using the finite element method. The developed finite element models take into account the effects of material and geometric nonlinearities; the accuracy of proposed models is validated through comparison against independent experimental results. The mechanical performance of CFST column-base connections with both permanent and demountable design details are compared with the developed finite element models. Parametric studies are further carried out to examine the effects of design parameters on the behaviour of demountable circular CFST column-base connections. Moreover, the initial stiffness and moment capacity of such demountable connections are compared with the existing codes of practice. The comparison results indicate that an improved prediction method of the initial stiffness for these connections should be developed.

Extensometers results correction in concrete dams: A case study in RCC Zhaveh Dam

  • Ziaei, Ahad;Ahangari, Kaveh;Moarefvand, Parviz;Mirzabozorg, Hasan
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.1
    • /
    • pp.17-31
    • /
    • 2017
  • Since extensometers are used to determine the absolute deformation of foundation and abutments and all results are obtained in reference to the base rod, the accuracy of these results has been constantly a subject of debate. In this regard, locating and installing extensometers outside the range of effect zone is also another challenge. The main purpose of this paper is to investigate and modify extensometers results based on the mentioned issues. For this aim, the concrete RCC Zhaveh dam in Iran was selected as the case study. To study the results of extensometers installed in this dam, first, the 3DEC_DP 5.00 software was applied for numerical modeling. Parameters such as discontinuities, dead load and piezometric pressure in the interface of concrete and rock were considered. Next, using the results obtained from 6 extensometers in foundation and abutments and 4 clinometers in dam body, the numerical model was calibrated through back analysis method. The results indicate that the base rod is moved and is not recommended being used as the base point. In other words, because installation of base anchor outside the range of effect zone is not possible due to the operational and economic considerations, the obtained results are not accurate enough. The results indicate a considerable 2-3 mm displacement of the base rod (location of the base anchor) in reference to the real zero point location, which must be added to the base rod results.

Fundamental Study on Pervious Concrete Materials for Airport Pavement Cement Treated Base Course (공항포장 시멘트안정처리기층에 적용하기 위한 투수콘크리트 개발에 관한 기초연구)

  • Kim, Seung Won;Oh, Ji Hyeon;Jang, Bong Jin;Ju, Min Kwan;Kim, In Tai;Park, Cheol Woo
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.65-73
    • /
    • 2013
  • PURPOSES : As a research to develop a cement treated base course for an airport pavement which can enhance its drainage, this paper investigated the strength, infiltration performance and durability of the pervious concrete with respect to maximum coarse aggregate sizes and compaction methods. METHODS : This study measured compressive strength, infiltration rate, continuous porosity and freeze-thaw resistance of pervious concrete specimens, which were fabricated with five different compaction methods and different maximum aggregate sizes. In addition, in order to reduce the usage of Portland cement content and to enhance environment-friendliness, a portion of the cement was replaced with Ground Granulated Blast Furnace Slag (GGBS). RESULTS: Compressive strength requirement, 5 MPa at 7 days, was met for all applied compaction methods and aggregate sizes, except for the case of self-compaction. Infiltration rate became increased as the size of aggregate increased. The measured continuous porosities varied with the different compaction methods but the variation was not significant. When GGBS was incorporated, the strength requirement was successfully satisfied and the resistance to freezing-thawing was also superior to the required limit. CONCLUSIONS: The infiltration rate increased as the maximum size of aggregate increased but considering construct ability and supply of course aggregate, its size is recommended to be 25mm. With the suggested mix proportions, the developed pervious concrete is expected to successfully meet requirements for strength, drainage and durability for cement treated base or subbase course of an airport pavement.

The Absorption Characteristics of Foamed Concrete for On-dol (온돌 바닥용 경량기포콘크리트의 흡수특성)

  • 이도헌;전명훈;임정수;정민철;김경덕;민승의
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.225-230
    • /
    • 2001
  • Cast-in-place foamed concrete is a high porous material placed as base the layer of mortar screeds in the panel heating system, so the quality of mortar is affected by it. Therefore, this study is aims to investigate how the absorption characteristics of foamed concrete influences on mortar screeds according to the foamed ratio-62%, 67% and 72%- and the surface treatments of foamed concrete-water and acrylic emulsion primer spray, etc. The result of this study shows that water-spray in the surface of foamed concrete has a good effects to reduce mortar cracking.

  • PDF