• 제목/요약/키워드: barrier discharge

검색결과 397건 처리시간 0.024초

애자류의 염해대책에 관한 기초연구 (A basic study on preventing insulators from salt accident)

  • 김원섭
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.11-14
    • /
    • 1969
  • This paper shows experimentally one method of preventing porcelain insulators from salt accident likely to be caused in the region of sea coast. In this experiment some results that, if a conductor barrier is inserted into the flash over discharge path which is wetted by salt dissolved water, the flash over voltage found to be raised up, were gotten. This results may be actually applied to suspension insulator or bushing to prevent them from salt accidents.

  • PDF

Remote Plasma Etching of Photoresist Using Pin-To-Plate Dielectric Barrier Discharge

  • 박재범;경세진;염근영
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 춘계학술발표회 초록집
    • /
    • pp.82-83
    • /
    • 2007
  • DBD type을 이용한 remote plasma에서 발생된 대기압 플라즈마를 이용하여, PR에 대한 식각 실험을 진행하였다. 과거 습식 화학적 공정에서 오던 기술적 제한의 극복과 진공 플라즈마 가지는 단점을 극복하기 위해 대기압 플라즈마를 이용한 건식 세정에 관한 연구를 진행하였고, 이 때 Gas는 $N_2/O_2$+$SF_6$ 의 조합으로 사용하였으며, 각 gas의 유량에 다른 remote 플라즈마의 전기적, 광학적 특성에 대해 관찰하였다.

  • PDF

교류전압에서 PD 패턴 및 유전체 장벽 방전에 미치는 공간전하의 영향 (The Effect of Space Charge on the PD Pattern and Dielectric Barrier Discharge under AC)

  • 권윤혁;황보승;이동영;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권4호
    • /
    • pp.226-231
    • /
    • 2000
  • In this paper, we present new method to analyze the space charge effect on the electrical characteristics in polymer. It is new measurement system and analysis method that have not reported yet. By using this measurement system, we make observation to space charge accumulated on the surface of polymer at AC voltage, so it is examined to verify the correlation of space charge and partial discharge(PD). In the result of experiment, it can be known that PD pattern is related more closely to space charge accumulated on the surface of polymer than in the inner part, and applied voltage in the air is ruled by this dynamic partial discharge. Also, above critical voltage, the space charge accumulated on the surface of polymer have no effect to the magnitude of PD and the applied voltage in the air. It has been known that the electric power of the dissolution system is proportioned to the frequency and the magnitude of applied voltage, but we can know by this result of the experiment that the efficiency of the dissolution is not related to the rise of voltage above critical voltage.

  • PDF

플라즈마 디스플레이 패널의 압력별 3차원 시간 분해 측정 (The measurement of three-dimensional temporal behavior according to the pressure in the plasma display panel)

  • 김성익;최훈영;이석현;이승걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1628-1630
    • /
    • 2002
  • In this paper, we measured 3-dimensional temporal behavior of the light emitted from discharge cell of plasma display panel(PDP) as a function of the pressure using the scanned point detecting system. The detected light signal through the PM tube is sent on the oscilloscope and oscilloscope which is connected to PC with GPIB. The whole system is controlled by a PC. From the temporal behavior results, we could analyze the discharge behavior of panel with Ne-Xe(4%) mixing gas and 300torr, 400torr, 500torr pressure. The top view of panel shows that the discharge moves from inner edge of cathode electrode to outer cathode electrode forming arc type. At the 300torr, initial emission time is very fast. The side view of panel shows that the light is detected up to $150{\mu}m$ height of barrier rib. In the panel of 300torr, emission distribution is wider than the others.

  • PDF

마이크로캡슐화한 축전지용 수소저장합금 전극의 충·방전 특성 (Charge and Discharge Characteristics of Microencapsulated Hydrogen Storage Alloy Electrodes for Secondary Batteries)

  • 최성수;최병진;예병준;김대룡
    • 한국수소및신에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.45-54
    • /
    • 1992
  • An applicability microencapsulation, using electroless copper plating, of hydrogen storage alloy powder as an anode material for nickel-hydrogen secondary batteries was investigated. Alloys employed were $LaNi_{4.7}Al_{0.3}$ and $MmNi_{4.5}Al_{0.5}$(Mm=mischmetal) which have an appropriate equilibrium pressure and capacity. The microencapsulation of the alloy powder was found to accelerate initial activation of electrodes and to increase capacity which is about 285mAh/g for $LaNi_{4.7}Al_{0.3}$. In addition, other charge and discharge characteristics, such as polarization and flatness of charge and discharge potential, were improved due to the role of copper layer as a microcurrent collector and an oxidation barrier of the alloy powder. $MmNi_{4.5}Al_{0.5}$ alloy showed lower capacity than $LaNi_{4.7}Al_{0.3}$ because of higher equilibrium pressure. Cyclic characteristics of both alloys were somewhat poor because of mainly shedding and partial oxidation of alloy powder during the cycling. However, it was considered that the microencapsulation method is effective to improve the performances of the hydrogen storage alloy electrodes.

  • PDF

새만금해역에서 밀도성층의 계절 변동 (Seasonal Variation of Density Stratification in the Saemangeum Waters, Korea)

  • 김태인;이형래;장경일
    • Ocean and Polar Research
    • /
    • 제28권3호
    • /
    • pp.339-352
    • /
    • 2006
  • Seasonal and tidal variations of density stratification in the Saemangeum waters are investigated based on synoptic CTD observations between July 2003 and September 2005. CTD data used in this study are those obtained after closing the dike No. 4 and before closing the two final gaps, the Sinsi and the Garyeok, on the Saemangeum tidal harrier. A total of 19 field campaigns comprehend a wide temporal spectrum, that is, few seasons, spring and neap tides, and high and low waters. In addition, ADCPs were anchored and CTDs were cast at three stations for 25 h in July 2005. Water columns are vertically homogeneous in autumn and winter. The vertical homogeneity persists in spring but with an occasional weak stratification in i:he northern part of the Gogunsan Islands. Increased reshwater runoff tends to stabilize the water columns and strong density stratification is established in summer. The mean potential energy anomaly (PEA) in summer used as a stratification parameter is the largest $(27.7\;J\;m^{-3})$ in the northern part of the Gogunsan Islands where the Geum River discharge dominates, the smallest $(16.9\;J\;m^{-3})$ is in the inner area of the barrier, in between the two $(21.6\;J\;m^{-3})$ in the southern part of the Gogunsan Islands. Whereas the stratification is generally strengthened in summer, strong winds or large tidal currents over the shallow depths frequently destratify the water column near the mouth of river runoff inside the tidal barrier. Periodic stratification, the development of stratification on the ebb and its breakdown on the flood, occurs in the mid-area inside the barrier induced by the tidal straining, which can also be found in the results of 25 h observation.

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화 (Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

대기압 플라스마에 의한 폴리우레탄 필름의 표면 개질 (Surface Modification of Polyurethane Film Using Atmospheric Pressure Plasma)

  • 양인영;명성운;최호석;김인호
    • 폴리머
    • /
    • 제29권6호
    • /
    • pp.581-587
    • /
    • 2005
  • 상업용 폴리우레탄(PU) 필름의 표면 개질 목적으로 대기압에서 플라스마를 발생시키기 위한 dielectric barrier discharge(DBD) 구조의 평판형 플라스마 반응기 내에서 이온화된 아르곤 플라스마를 사용하였다. 플라스마 처리 공정변수인 처리 시간, 처리 RF-power, 아르곤 가스 유속을 변화시켜가며 접촉각을 측정하여 젖음성과 표면 자유 에너지 변화를 알아보았고, 필름 표면 위에 과산화물을 최대로 도입시키기 위해 플라스마 처리 공정변수를 최적화하였다. 대기압 플라스마 처리 시간 70초, RF-power 120 W, 아르곤 가스유속 6 liter per minute(LPM)에서 가장 높은 젖음성과 표면 자유 에너지 값을 보였고, 1,1-diphenyl-2-picrylhydrazy(DPPH) 법을 사용하여 PU 필름의 표면에 생성된 과산화물의 농도를 정량한 결과, 처리 시간 30초, RF-power 80 W, 아르곤 가스유속 6 LPM의 플라스마 처리 조건에서 최대 2.1 nmol/$\cm^{2}$의 과산화물이 생성되었다.

유체 모델을 이용한 유전체 장벽 방전 플라즈마와 전자기파 간의 시간 의존적 상호 작용 분석 (Time Dependent Interaction between Electromagnetic Wave and Dielectric Barrier Discharge Plasma Using Fluid Model)

  • 김유나;오일영;정인균;홍용준;육종관
    • 한국전자파학회논문지
    • /
    • 제25권8호
    • /
    • pp.857-863
    • /
    • 2014
  • 전자기파와 플라즈마의 상호 작용을 결정하는 주요 변수는 플라즈마 주파수와 충돌 주파수이며, 이 둘은 각각 전자 밀도와 전자 온도로부터 계산할 수 있다. 이 두 값은 플라즈마 발생기 종류에 따라 결정되는 시간 의존적인 변수이다. 기존의 전파 흡수 특성 연구에서는 수치 해석적 모형의 부재로 인하여 플라즈마의 시간적/공간적 변화를 간략화하거나, 상수로 가정하여 수행하였다. 본 연구에서는 플라즈마 유체 모델을 도입하여 얻어진 시간 의존적 변수 값을 전자기파감쇠량 계산에 이용함으로써 해석의 정확도를 높이는 방식을 제안하였다. 해석 대상인 유전체 장벽 방전 플라즈마는 구조적인 단순함으로 인하여 1차원 분석만으로 플라즈마 분포의 시간적 변화를 반영할 수 있다. 본 논문은 한 주기 내에서 전자 밀도와 전자 온도를 추출하여 마이크로파 입사 시 시간적 흡수 특성 변화를 분석하였다. 또한, 전자 밀도와 전자 온도의 변화에 따라 감쇠량을 계산하여 감쇠 경향성을 분석하였다.

Effect of Plasma Area on Frequency of Monostatic Radar Cross Section Reduction

  • Ha, Jungje;Shin, Woongjae;Lee, Joo Hwan;Kim, Yuna;Kim, Doosoo;Lee, Yongshik;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제17권3호
    • /
    • pp.153-158
    • /
    • 2017
  • This work reports on the effect of plasma area on the frequency characteristics of the monostatic radar cross section (RCS) of a square metallic plate. A dielectric barrier discharge (DBD) plasma actuator consisting of 10 rings is proposed. The actuator is fabricated in three different configurations such that only three inner rings, seven inner rings, and all rings can be biased. By applying an 18-kV bias at 1 kHz, the three types of DBD actuators generate plasma with a total area of 16.96, 36.74, and $53.69cm^2$, respectively, in a ring or circular form. The experimental results reveal that when the DBD actuator is placed in front of a $20mm{\times}20cm$ conducting plate, the monostatic RCS is reduced by as much as 18.5 dB in the range of 9.41-11.65 GHz. Furthermore, by generating the plasma and changing the area, the frequency of maximum reduction in the monostatic RCS of the plate can be controlled. The frequency is reduced by nearly 20% in the X band when all rings are biased. Finally, an electromagnetic model of the plasma is obtained by comparing the experimental and full-wave simulated results.