• Title/Summary/Keyword: bare

Search Result 1,495, Processing Time 0.029 seconds

Synthesis and Low-concentration (50 ppm) NO2 Sensing Properties of Bare and ZnO (n) Decorated TeO2 (p) Nanowires (ZnO가 첨가된 TeO2 나노와이어의 합성 및 저농도(50 ppm) 이산화질소 가스 센싱 특성)

  • Yu, Dong Jae;Shin, Ka Yoon;Oum, Wansik;Kang, Suk Woo;Kim, Eun Bi;Kim, Hyeong Min;Kim, Hyoun Woo
    • Korean Journal of Materials Research
    • /
    • v.32 no.10
    • /
    • pp.435-441
    • /
    • 2022
  • We report the synthesis and gas sensing properties of bare and ZnO decorated TeO2 nanowires (NWs). A catalyst assisted-vapor-liquid-solid (VLS) growth method was used to synthesize TeO2 NWs and ZnO decoration was performed using an Au-catalyst assisted-VLS growth method followed by a subsequent heat treatment. Structural and morphological analyses using X-ray diffraction (XRD) and scanning/transmission electron microscopies, respectively, demonstrated the formation of bare and ZnO decorated TeO2 NWs with desired phase and morphology. NO2 gas sensing studies were performed at different temperatures ranging from 50 to 400 ℃ towards 50 ppm NO2 gas. The results obtained showed that both sensors had their best optimal sensing temperature at 350 ℃, while ZnO decorated TeO2 NWs sensor showed much better sensitivity towards NO2 relative to a bare TeO2 NWs gas sensor. The reason for the enhanced sensing performance of the ZnO decorated TeO2 NWs sensor was attributed to the formation of ZnO (n)/ TeO2 (p) heterojunctions and the high intrinsic gas sensing properties of ZnO.

Classifications of Ecological Districts for Estuarine Ecosystem Restoration; Examples of Goseong Bay Estuaries, South sea, Korea (하구 생태 복원을 위한 생태구역 구분; 남해 고성만 고성천 인근 하구의 예)

  • An, Soon-Mo;Lee, Sang-Yong;Choi, Jae-Ung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.2
    • /
    • pp.70-80
    • /
    • 2011
  • Estuarine ecosystem responds sensitively to natural and anthropogenic perturbations. lt is necessary to identify the direction of the change when the perturbation occurs as well as to understand the structure and functioning of estuarine ecosystem for a proper management of the area. In this study, the estuarine habitats were classified into different ecological districts so as to the switch from one district to another district could be related to the environmental change due to the perturbations. Total 16 ecological districts was defined according to the presence of barrage, salinity and vegetation characteristics. The defined ecological districts were applied to small estuaries in Goseong bay, south sea of Korea (Baedun, Guman, Maam, Goseong) to distinguish different regions which might have characteristic bottom topography, inclinations of river bottom, sediment characteristics, salinity structure and area of vegetation. Total 7 out of 16 ecological district was identified in this region; NFB (natural, fresh, bare), NHB (natural, high salinity, bare), NLV (natural, low salinity, vegetated) in natural (without barrage) estuaries and CFB (closed, fresh, bare), CFV( closed, fresh vegetated), CLV (closed, low salinity, vegetated), CHB (closed, high salinity, bare) in closed (with barrage) estuary. A comparison of environmental factors and biota between CHB and CLV demonstrated the effect of barrage on estuarine ecosystem. The height and sediment characteristics of CHB and CLV were similar but the average salinity was lower in CLV than in CHB due to the barrage, which produced favorable condition for the Phragmites australis in CLV. Information regarding the ecological districts in various sizes and location could be useful for predicting the ecosystem change due to natural and anthropogenic perturbations and for preparing management actions.

Solar Module with a Glass Surface of AG (Anti-Glare) Structure (연요철(Anti-Glare) 구조의 표면 유리 기판을 가지는 고효율 태양전지 모듈)

  • Kong, Dae-Young;Kim, Dong-Hyun;Yun, Sung-Ho;Bae, Young-Ho;Yu, In-Sik;Cho, Chan-Seob;Lee, Jong-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.233-241
    • /
    • 2011
  • Currently, solar module is using the two methods such as a glass-filled method or a super-straight method. The common point of these methods is to use glass structure on the front of solar module. However, the reflectance of the solar module is high depending on the height of the incident sunlight due to the flat surface of the module front glass. Purposed to solve these problems, AG (anti-glare) structures were formed on the glass surface. Next is fabrication methods of AG structure. First, uneven structure made by micro blaster equipment was dipped in Hydro-fluidic acid (HF) acid. HF acid process was carried out to remove particles and to make high transmittance. The reflectance and transmittance of the anti-glare glass was compared to those of the bare glass. The reflectance of anti-glare glass decreased approximately 1% compared with bare glass. The transmittance of anti-glare glass was similar to bare glass. According to the sample angle, the difference of the reflectance between bare glass and the anti-glare glass was about 19%. Isc and efficiency value of anti-glare glass on bare solar cell appeared about 3.01 mA and 0.228% difference compared with bare glass. Anti-glare glass on textured solar cell appeared about 9.46 mA and 0.741% difference compared with bare glass. As a result, the role of anti-glare in the substrate is to reduces the loss of sunlight reflected from the surface. In this study, therefore, AG structure on the solar cell was used to improve the efficiency of solar cell.

Flow and Convective Heat Transfer Analysis Using RANS for A Wire-Wrapped Fuel Assembly

  • Ahmad, Imteyaz;Kim, Kwang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1514-1524
    • /
    • 2006
  • This work presents the three-dimensional analysis of flow and heat transfer performed for a wire-wrapped fuel assembly of liquid metal reactor using Reynolds-averaged Wavier-Stokes analysis in conjunction with 557 model as a turbulence closure. The whole fuel assembly has been analyzed for one period of the wire-spacer using periodic boundary conditions at inlet and outlet of the calculation domain. Three different assemblies, two 7-pin wire-spacer fuel assemblies and one bare rod bundle, apart from the pressure drop calculations for a 19-pin case, have been analyzed. Individual as well as a comparative analysis of the flow field and heat transfer have been discussed. Also, discussed is the position of hot spots observed in the wire-spacer fuel assembly. The flow field in the subchannels of a bare rod bundle and a wire-spacer fuel assembly is found to be different. A directional temperature gradient is found to exist in the subchannels of a wire-spacer fuel assembly Local Nusselt number in the subchannels of wire-spacer fuel assemblies is found to vary according to the wire-wrap position while in case of bare rod bundle, it's found to be constant.

Long-term Dissolution Behavior of Cesium from Spent PWR Fuel in Contact with Compacted Bentonite under Synthetic Granitic Groundwater

  • Chun, Kwan-Sik;Kim, Seung-Soo;Bak, Seong-Jea;Park, Jongwon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.167-173
    • /
    • 2004
  • The amount of cesium released from the leaching of spent fuels in contact with and without the compacted bentonite bloc]t which was compacted as the density of $1.4g/\textrm{cm}^3$, up to 5.7 years were measured and the empirical formula of the fractional release rate of cesium were derived from these measured values. The empirical formulas show that the long-term release rate of cesium under a repository would become a constant, as about $3{\times}10_{-6}$ fraction/day, after a certain period. The cumulative fractions of cesium released from the spent fuel with bentonite and with copper and stainless steel sheets were steadily increased, but the fraction from bare fuel was rapidly increased and then sluggishly increased. However, the remained value except its gap inventory from the cumulative fraction of cesium released from bare fuel was almost very close to the others. This suggests that the initial release of cesium from bare fuel might be dependant on its gap inventory.

  • PDF

Soil Moisture Content Estimation Using Remote Sensing Technique (원격 측정 기법을 이용한 토양 함수비의 측정)

  • Lee, Jae Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.535-542
    • /
    • 1994
  • Remote sensing technique is based on the estimation of land surface characteristics from the measurement of the emitted radiation from the earth. The hydrologically related parameters studied using this approach include surface temperature, evapotranspiration, soil moisture, precipitation and snow. This study introduces a method for estimating moisture content of a bare soil from the observed and simulated brightness temperature. In a bare soil, microwave emission depends on moisture content, soil temperature, and surface roughness. The method is based on a radiative transfer model with some modifications of Fresnel reflection coefficient to take into account the effect of surface roughness. One smooth bare field and two fields with different surface roughness are prepared for the study. The results indicate that the effect of surface roughness is to increase the soil's brightness temperature and to reduce the slope of regression between brightness temperature and moisture contents.

  • PDF

Contribution of non-structural brick walls distributions on structures seismic responses

  • Farghaly, Ahmed Abdelraheem;Rahim, Hamdy H.A. Abdel
    • Earthquakes and Structures
    • /
    • v.5 no.5
    • /
    • pp.553-570
    • /
    • 2013
  • Using of masonry infill as partitions, in flat slab frame buildings is a common practice in many parts of the world. The infill is, generally, not considered in the design and the buildings are designed as bare frames. More of fundamental information in the effect of masomary infill on the seismic performance of RC building frames is in great demand for structural engineers. Therefore the main aim of this research is to evaluate the seismic performance of such buildings without (bare frame) and with various systems of the masonary infill. For this purpose, thirteen three dimensional models are chosen and analyzed by SAP2000 program. In this study the stress strain relation model proposed by Crisafulli for the hysteric behaviour of masonary subjected to cyclic loading is used. The results show that the nonstructural masonary infill can impart significant increase global strength and stiffness of such building frames and can enhance the seismic behaviour of flat slab frame building to large extent depending on infill wall system. As a result great deal of insight has been obtained on seismic response of such flat slab buildings which enable the structural engineer to determine the optimum position of infill wall between the columns.

Experimental Correlation of Wettability for Micro-scale Hatched Tubes (미소해칭 전열관의 젖음률에 대한 실험적 상관식)

  • 김진경;박찬우;이경엽;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • The objectives of this paper are to develop a new method of wettability mea-surement and to study the effect of surface roughness on the wettability in a $H_2O$/LiBr falling film absorber. Two absorber tubes with micro-scale roughness and a bare tube are tested in a falling film absorber installed in a test rig. Inlet solution temperature, concentration and mass flow rate are considered as key parameters. A new method is proposed to estimate the wettability of a tube by measuring a minimum mass flow rate to wet the tube completely. The wettability for the structured surfaces was higher than that for the bare tube. The wettability decreased linearly along the vertical location. The wettability increased with increasing the solution temperature and the solution mass flow rate. The experimental correlations of the wettability for the bare and the micro-hatched tubes were developed with error bands of$\pm20%\;and\;\pm10%$, respectively. This work can be used in the design of absorbers with micro-scale roughness.

A Numerical Study on Temperature Prediction Bias using FDS in Simulated Thermal Environments of Fire (모사된 화재의 열적환경에서 FDS를 이용한 온도 예측오차에 관한 수치해석 연구)

  • Han, Ho-Sik;Kim, Bong-Jun;Hwang, Cheol-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.14-20
    • /
    • 2017
  • A numerical study was conducted to identify the predictive performance for the bare-bead thermocouple (TC) using FDS (Fire Dynamics Simulator) in simulated thermal environments of fire. A relative prediction bias of TC temperature calculated from reverse-radiation correction by FDS was evaluated with the comparison of previous experimental data. As a result, it was identified that the TC temperatures predicted by FDS were lower than the temperatures measured by bare-bead TC for the ranges of heat flux and gas temperature considered. The relative prediction bias of TC temperature by FDS was gradually increased with the increase in radiative heat flux and also significantly increased with the decrease in the gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the TC temperature predicted by FDS had the relative bias of approximately -20% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. It is predicted from the present study that more accurate validation of fire modeling will be possible with the quantitative prediction bias occurred in the process of reverse-radiation correction of temperature predicted by FDS.

Study of CO Oxidation on Bare and $TiO_2$-coated NiO/$Ni(OH)_2$

  • Nam, Jong-Won;Kim, Kwang-Dae;Kim, Dong-Wun;Seo, Hyun-OoK;Kim, Young-Dok;Lim, Dong-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.109-109
    • /
    • 2011
  • CO oxidaition reacitvity of bare and $TiO_2$ -coated NiO/$Ni(OH)_2$ nanoparticles was studied. For the deposition of $TiO_2$ atomic layer deposition was used, and formation of three-dimensional island of $TiO_2$ on NiO/$Ni(OH)_2$ could be identified. Based on the data of X-ray Photoelectron Spectroscopy, we suggest that only $Ni(OH)_2$ existed on the surface, whereas NiO disappeared upon $TiO_2$ deposition. Both CO adsorption and CO oxidation took place on NiO/$Ni(OH)_2$ surfaces under our experimental conditions. CO adsorption was completely suppressed after $TiO_2$ deposition, whereas CO oxidation activity was maintained to large extent. It is proposed that bare NiO can uptake CO under our experimental condition, whereas hydroxylated surface of NiO can be active for CO oxidation.

  • PDF