• Title/Summary/Keyword: band image

Search Result 1,003, Processing Time 0.024 seconds

Development of Drought Stress Measurement Method for Red Pepper Leaves using Hyperspectral Short Wave Infrared Imaging Technique (초분광 단파적외선 영상 기술을 이용한 고추의 수분스트레스 측정 기술 개발)

  • Park, Eunsoo;Cho, Byoung-Kwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.50-55
    • /
    • 2014
  • This study was conducted to investigate the responses of red pepper (Hongjinju) leaves under water stress. Hyperspectral short wave infrared (SWIR, 1000~1800 nm) reflectance imaging techniques were used to acquire the spectral images for the red pepper leaves with and without water stress. The acquired spectral data were analyzed with a multivariate analysis method of ANOVA (analysis of variance). The ANOVA model suggested that 1449 nm wavebands was the most effective to determine the stress responses of the red pepper leaves exposed to the water deficiency. The waveband of 1449 nm was closely related to the water absorption band. The processed spectral image of 1449 nm could separate the non-stress, moderate stress (-20 kPa), and severe stress (-50 kPa) groups of red pepper leaves distinctively. Results demonstrated that hyperspectral imaging technique can be applied to monitoring the stress responses of red pepper leaves which are an indicator of physiological and biochemical changes under water deficiency.

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Study on Application of Ultrasonic Propagation Imager for Non-destructive Evaluation of Composite Lattice Structure (복합재 격자 구조 비파괴평가를 위한 초음파전파 영상화 시스템 활용 연구)

  • Park, Jae-Yoon;Shin, Hye-Jin;Lee, Jung-Ryul
    • Composites Research
    • /
    • v.30 no.6
    • /
    • pp.356-364
    • /
    • 2017
  • Composite lattice structures are tried to be used in various fields because of its benefit in physical properties. With increase of demand of the composite lattice structure, nondestructive testing technology is also required to certificate the quality of the manufactured structures. Recently, research on the development of the composite lattice structure in Republic of Korea was started and accordingly, fast and accurate non-destructive evaluation technology was needed to finalize the manufacturing process. This paper studied non-destructive testing methods for composite lattice structure using laser ultrasonic propagation imaging systems. Pulse-echo ultrasonic propagation imaging system was able to inspect a rib structure wrapped with a skin structure. To reduce the time of inspection, a band divider, which can get signal in different frequency bands at once, was developed. Its performance was proved in an aluminum sandwich panel. In addition, to increase a quality of results, curvature compensating algorithm was developed. On the other hand, guided wave ultrasonic propagation imaging system was applied to inspect delamination in a rib structure. To increase an area of inspection, multi-source ultrasonic wave propagation image was applied, and defects were successfully highlighted with variable time window amplitude mapping algorithm. These imply that ultrasonic propagation imaging systems provides fast and accurate non-destructive testing results for composite lattice structure in a stage of the manufacturing process.

The Radiological Findings of the Catheters Inserted 10cm Cephaladly in Epidural Space (경막외강내 두측으로 10cm 삽입한 카테터의 X-선상 소견)

  • Chung, So-Young;Lee, Hyo-Keun;Chae, Jin-Ho;Lee, Chul-Seung;Lee, Chul;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.298-303
    • /
    • 1995
  • We have inserted epidural catheter for single or continuous injection of a drug for epidural analgesia. It is important to localize the tip of epidural catheter in appropriate site to acquire the most effective analgesia. In epidural block, we observed course and location of the tip of epidural catheter. Subject: 70 patients were divided into group I(non-injection of saline group during catheter insertion) and group II(injection group during catheter insertion). Group I included cervical(n=20), thoracic(n=10), and lumbar(n=20) epidural group. Group II, cervical(n=10), and lumbar(n=10) epidural group. Method: 19G FlexTip $Plus^{TM}$ Epidural Catheter ($Arrow^{(R)}$) was inserted 10cm cephaladly in epidural space with(group II) or without(group I) saline flushing. We observed course and location of the tip of epidural catheter by C-arm image intensifier during injection of contrast media ($Omnipaque^{(R)}$). Result: In group I, the number of tips of epidural catheters located within 2 cm from inserted site were: cervical 14/20(70%), thoracic 2/10(20%). lumbar 16/20(80%). In thoracic epidural blocks, tips of epidural catheters were more cephaladly located than with cervical and lumbar epidural blocks. With cervical epidural blocks, the number of tips of epidural catheters located within 2 cm from insertion site were less in group II than group I (20% vs. 70%). But no significant differences were noted between group I and group II with lumbar epidural block(90% vs. 80%). The number of tips of epidural catheters located around a predicted site were: cervical 2/20(10%), thoracic 4/10(40%), lumbar 0/20(0%) in group I, and cervical 2/10(20%), lumbar 1/10(10%) in group II. Conclusion: It was impossible to predict the exact location of tips of epidural catheters by measuring the inserted length without epidurogram. With many cases, tips of epidural catheters were located around the insertion site in lumbar epidural blocks, and in some cases around the predicted site in thoracic epidural blocks. The results suggests that epidural block should be done at a point near the required band of analgesia.

  • PDF

Study on Temperature Dependence of Molecular Structure in Stearic Acid LB Films Using FTIR-RAS (FTIR-RA 분광법을 이용한 스테아르산 단분자막에서 분자구조의 온도의존성 고찰)

  • Kim, Dong Won;Park, Sang Rae;Umemura Junjo;Takeda Satoshi;Hasegawa Takeshi;Takenaka Tohru;Lee Hai Won
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.570-576
    • /
    • 1993
  • 1-, 3-, 9-, and 21-Monolayer Langmuir-Blodgett(LB) films of stearic acid were deposited on silver-coated glass slides at the surface pressure of 30 mN/m. Fourier transform infrared(FTIR) reflection-absorption spectra (RAS) of these LB films were recorded at various temperatures from 31 to $72^{\circ}C.$ The spectra at $31^{\circ}C$ exhibited characteristic features of highly perpendicular orientation of the hydrocarbon chain. In the 1-monolayer LB film, the C=O stretching band was not observed, presumably due to the image dipole effect on the silver surface. In the 1-and 3-monolayer LB films, the trans isomer of stearic acid was prominent, but the cis isomer was dominant in the 21-monolayer LB film. FTIR-RAS measurements at an elevated temperature indicated that the chain melting temperature increases and approached to the bulk melting point with increasing the number of monolayer, except for the 1-monolayer LB film which has a higher melting temperature than the 3-monolayer film due to the strong interaction with the silver substrate.

  • PDF

Estimation of Simulated Radiances of the OSMI over the Oceans (대양에서의 OSMI 모의 복사량 산출)

  • 임효숙;김용승;이동한
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.227-238
    • /
    • 1999
  • In advance of launch, simulated radiances of the Ocean Scanning Multispectral Imager (OSMI) will be very useful to guess the real imagery of OSMI and to prepare for data processing of OSMI. The data processing system for OSMI which is one of sensors aboard Korea Multi-Purpose Satellite (KOMPSAT) scheduled for launch in 1999 is developed based on the SeaWiFS Data Analysis System (SeaDAS). Simulation of radiances requires information on the spectral band, orbital and scanning characteristics of the OSMI and KOMPSAT spacecraft. This paper also describes a method to create simulated radiances of the OSMI over the oceans. Our method for constructing a simulated OSMI imagery is to propagate a KOMPSAT orbit over a field of Coastal Zone Color Scanner (CZCS) pigment concentrations and to use the values and atmospheric components for calculation of total radiances. A modified Brouwer-Lyddane model with drag was used for the realistic orbit prediction, the CZCS pigment concentrations were used to compute water-leaving radiances, and a variety of radiative transfer models were used to calculate atmospheric contributions to total radiances detected by OSMI. Imagery of the simulated OSMI radiances for 412, 443, 490, 555, 765, 865nm was obtained. As expected, water-leaving radiances were only a small fraction (below 10%) of total radiances and sun glint contaminations were observed near the solar declination. Therefore, atmospheric correction is critical in the calculation of pigment concentration from total radiances. Because the imagery near the sun's glitter pattern is virtually useless and must be discarded, more advanced data collection planning will be required to succeed in the mission of OSMI which is consistent monitoring of global oceans during three year mission lifetime.

Thermal Design of Electronic for Controlling X-band Antenna of Compact Advanced Satellite (차세대 중형위성 탑재 X-밴드 안테나 구동용 전자유닛 APD 열설계 및 열해석)

  • Kim, Hye-In;You, Chang-Mok;Kang, Eun-Su;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.1
    • /
    • pp.57-67
    • /
    • 2018
  • The APD (Antenna Pointing Driver) is an electronic equipment tool that is used to drive the two-axis gimbal-type antenna for the image data transmission of CAS (Compact Advanced Satellite). In this study, a heat dissipation of EEE (Electrical, Electronic and Electromechanical) is reviewed, to identify the parts that directly affected its efficiency, lifetime as well as the reliability of the structure. This event eventually incurs a failure of the EEE part itself, or even the entire satellite system as noted in experiments in this case. To guarantee reliability of electronic equipment during the mission, the junction temperature of EEE parts is considered a significant and important design factor, and subsequently must be secured within the allowable range. Therefore, the notation of the thermal analysis considering the derating is indispensable, and a proper thermal mathematical model should be constructed for this case. In this study, the thermal design and thermal analysis are performed to confirm the temperature requirement of the APD. In addition, we noted that the validity of the thermal model, according to each of the identified modeling methods, was therefore compared through the thermal analysis utilized in this case.

Field and remote acquisition of hyperspectral information for classification of riverside area materials (현장 및 원격 초분광 정보 계측을 통한 하천 수변공간 재료 구분)

  • Shin, Jaehyun;Seong, Hoje;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1265-1274
    • /
    • 2021
  • The analysis of hyperspectral characteristics of materials near the South Han River has been conducted using riverside area measurements by drone installed hyperspectral sensors. Each spectrum reflectance of the riverside materials were compared and analyzed which were consisted of grass, concrete, soil, etc. To verify the drone installed hyperspectral measurements, a ground spectrometer was deployed for field measurements and comparisons for the materials. The comparison results showed that the riverside materials had their unique hyperspectral band characteristics, and the field measurements were similar to the remote sensing data. For the classification of the riverside area, the K-means clustering method and SVM classification method were utilized. The supervised SVM method showed accurate classification of the riverside area than the unsupervised K-means method. Using classification and clustering methods, the inherent spectral characteristic for each material was found to classify the riverside materials of hyperspectral images from drones.

Analysis of the Surface Urban Heat Island Changes according to Urbanization in Sejong City Using Landsat Imagery (Landsat영상을 이용한 토지피복 변화에 따른 행정중심복합도시의 표면 열섬현상 변화분석)

  • Lee, Kyungil;Lim, Chul-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.225-236
    • /
    • 2022
  • Urbanization due to population growth and regional development can cause various environmental problems, such as the urban heat island phenomenon. A planned city is considered an appropriate study site to analyze changes in urban climate caused by rapid urbanization in a short-term period. In this study, changes in land cover and surface heat island phenomenon were analyzed according to the development plan in Sejong City from 2013 to 2020 using Landsat-8 Operational Land Imager/Thermal Infrared Sensor (OLI/TIRS) satellite imagery. The surface temperature was calculated in consideration of the thermal infrared band value provided by the satellite image and the emissivity, and based on this the surface heat island effect intensity and Urban Thermal Field Variance Index (UTFVI) change analysis were performed. The level-2 land cover map provided by the Ministry of Environment was used to confirm the change in land cover as the development progressed and the difference in the surface heat island intensity by each land cover. As a result of the analysis, it was confirmed that the urbanized area increased by 15% and the vegetation decreased by more than 28%. Expansion and intensification of the heat island phenomenon due to urban development were observed, and it was confirmed that the ecological level of the area where the heat island phenomenon occurred was very low. Therefore, It can suggest the need for a policy to improve the residential environment according to the quantitative change of the thermal environment due to rapid urbanization.

Development of 3D Reverse Time Migration Software for Ultra-high-resolution Seismic Survey (초고해상 탄성파 탐사를 위한 3차원 역시간 구조보정 프로그램 개발)

  • Kim, Dae-sik;Shin, Jungkyun;Ha, Jiho;Kang, Nyeon Keon;Oh, Ju-Won
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.3
    • /
    • pp.109-119
    • /
    • 2022
  • The computational efficiency of reverse time migration (RTM) based on numerical modeling is not secured due to the high-frequency band of several hundred Hz or higher for data acquired through a three-dimensional (3D) ultra-high-resolution (UHR) seismic survey. Therefore, this study develops an RTM program to derive high-quality 3D geological structures using UHR seismic data. In the traditional 3D RTM program, an excitation amplitude technique that stores only the maximum amplitude of the source wavefield and a domain-limiting technique that minimizes the modeling area where the source and receivers are located were used to significantly reduce memory usage and calculation time. The program developed through this study successfully derived a 3D migration image with a horizontal grid size of 1 m for the 3D UHR seismic survey data obtained from the Korea Institute of Geoscience and Mineral Resources in 2019, and geological analysis was conducted.