• Title/Summary/Keyword: band failure

Search Result 131, Processing Time 0.031 seconds

A Study on Malfunction Mode of CMOS IC Under Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파로 인한 CMOS IC에서의 오동작 특성 연구)

  • Park, Jin-Wook;Huh, Chang-Su;Seo, Chang-Su;Lee, Sung-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.559-564
    • /
    • 2016
  • This study examined the malfunction mode of the HCMOS IC under narrow-band high-power electromagnetic wave. Magnetron is used to a narrow-band electromagnetic source. MFR (malfunction failure rate) was measured to investigate the HCMOS IC. In addition, we measured the resistance between specific pins of ICs, which are exposed and not exposed to the electromagnetic wave, respectively. As a test result of measurement, malfunction mode is shown in three steps. Flicker mode causing a flicker in LED connected to output pin of IC is dominant in more than 7.96 kV/m electric field. Self-reset mode causing a voltage drop to the input and output of IC during electromagnetic wave radiation is dominant in more than 9.1 kV/m electric field. Power-reset mode making a IC remained malfunction after electromagnetic radiation is dominant in more than 20.89 kV/m. As a measurement result of pin-to-pin resistance of IC, the differences between IC exposed to electromagnetic wave and normal IC were minor. However, the five in two hundred IC show a relatively low resistance. This is considered to be the result of the breakdown of pn junction when latch-up in CMOS occurred. Based on the results, the susceptibility of HCMOS IC can be applied to a basic database to IC protection and impact analysis of narrow-band high-power electromagnetic waves.

Application of AE for Fracture Behavior Evaluation of Carbon-fiber/SiC Reinforced Plastic Composites

  • Ryu, Yeong Rok;Kwon, Oh Heon
    • Composites Research
    • /
    • v.30 no.5
    • /
    • pp.267-272
    • /
    • 2017
  • In this study, SiC powder was added to twill woven carbon fiber reinforced plastic (CFRP) composites to improve its mechanical properties. An acoustic emission (AE) frequency analysis method was suggested for the prediction of failure behaviors. Tensile tests were conducted and the fracture characteristics of each component of the SiC reinforced composite were evaluated using AE. The results showed that SiC powder improved the strength of twill woven CFRP composites and the fracture behavior of the SiC reinforced CFRP composite and its crack extension could be effectively evaluated on the basis of the specific AE frequency bands which are 100 to 228 kHz and 428 to 536 kHz upon the resin failure and 232 to 424 kHz due to addition of SiC powder and 576 to 864 kHz at the fiber breakage.

A technique for optimally designing fibre-reinforced laminated structures for minimum weight with manufacturing uncertainties accounted for

  • Walker, M.
    • Steel and Composite Structures
    • /
    • v.7 no.3
    • /
    • pp.253-262
    • /
    • 2007
  • A methodology to design symmetrically laminated fibre-reinforced structures under transverse loads for minimum weight, with manufacturing uncertainty in the ply angle, is described. The ply angle and the ply thickness are the design variables, and the Tsai-Wu failure criteria is the design constraint implemented. It is assumed that the probability of any tolerance value occurring within the tolerance band, compared with any other, is equal, and thus the approach is a worst-case scenario approach. The finite element method, based on Mindlin plate and shell theory, is implemented, and thus effects like bending-twisting coupling are accounted for. The Golden Section method is used as the search algorithm, but the methodology is flexible enough to allow any appropriate finite element formulation, search algorithm and failure criterion to be substituted. In order to demonstrate the procedure, laminated plates with varying aspect ratios and boundary conditions are optimally designed and compared.

Structural Analysis and Failure Prediction of Tape-Wrapped Structures (테이프래핑 구조물의 구조 해석 및 파단 예측)

  • Goo, Nam-Seo;Park, Hoon-Cheol;Yoon, Kwang-Joon;Lee, Yeol-Hwa
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.17-21
    • /
    • 2004
  • Tape-wrapped structures have been generally used in nozzle parts of guided missiles. A continuous band of woven composite material is wrapped around a mandrel that is designed to produce real products. After going through a vacuum bagging process, this woven composite material is cured in a high-pressure autoclave or hydroclave. However, tape-wrapped structures are difficult to analyze because of its large thickness and inclined lay-up. The present study investigates the method of analysis and failure prediction of tape-wrapped structures. The four-point bending test and its finite element analysis were performed to study how to model tape-wrapped structures and investigate their failure characteristics.

Modelling of Shear Localisation in Geomaterials

  • Lee, Jun-Seok;Pan
    • Geotechnical Engineering
    • /
    • v.13 no.3
    • /
    • pp.21-32
    • /
    • 1997
  • In this paper, an enhanced finite element model based on homogenisation technique is proposed to capture the localized failure mode of the intact rock masses. For this, bifurcation analysis at the element level is performed and, once the bifurcation is detected, equivalent material properties of the shear band and neighbouring intact rock are used to trace the post -peak behaviour of the material. It is demonstrated that mesh sensitivity of the strain softening model is overcome and progressive failure mode of rock specimen can be simulated relaistically. Furthermore, the numerical results show that the crack propagation and final failure mode can be captured with relatively coarse meshes and compares well with the experimental data available.

  • PDF

Surgical Management of Ventricular Septal Defect in Infancy (영아기의 심실중격결손에 대한 이라완전교정술과 단계교정술의 비교)

  • 김병호
    • Journal of Chest Surgery
    • /
    • v.27 no.1
    • /
    • pp.24-30
    • /
    • 1994
  • Eighteen infants with a large ventricular septal defect[VSD] underwent primary surgical repair from January 1986 to December 1992. Operation was done because of failure to thrive, medically intractable heart failure, recurrent pneumonia, increased pulmonary vascular resistance[PVR]. Four patients[22.2%] died in the early postoperative period. Relief of heart failure and normalization of growth and weight gain was evident in all survivor. There was no late postoperative death. The results of primary surgical repair of VSD in infancy are compared with those of palliative pulmonary artery banding[PAB] and of VSD closure after PAB. Twenty-seven patients with isolated VSD or with VSD associated with atrial septal defect, patent ductus arteriosus, or coarctation of the aorta underwent initial palliative PAB. There were 3 early postoperative deaths[11.1%]. Severe elevation of PVR persisted in two patients. Closure of VSD and pulmonary artery debanding was done in twenty patients, with 2 early postoperative deaths[10.0%]. Placement of the PAB too close to the pulmonary annulus necessitated trasannular patching in one patient, but any problem caused by migration of the band was not developed. It is concluded that primary surgical repair of VSD in infancy is reasonable and that PAB is indicated only for those patients less than 6 months old with a complicated defect or in an emergency situation.

  • PDF

Development of SSPA-based X-band Transmitter with Graceful Degradation (점진적 성능저하 기능을 가지는 X-대역 SSPA 송신장치 개발)

  • Song, Hyeong-Min;Kim, Ji-Deok;Kang, Hyun-Chul;Song, Jae-Gyeong;Park, Chul-Soon;Rhee, Kye-Jin;Lee, Choung-Hyun;Kim, Dong-Gil
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.853-862
    • /
    • 2019
  • In this paper, we designed a 4.5kW X-band SSPA transmitter to replace the TWTA search radar transmitter with low MTBF and high maintenance cost. The transmitter is designed for the performance of over 520W average transmission output and 4.0kW maximum transmission output. In particular, by implementing a graceful degradation, it is designed to maintain better performance than conventional TWTA transmitter up to 40% (13 assembly modules) failure level of 200W power amplifier assembly. Through an experiment on the effective range of X-band, the performance of proposed transmitter verified the values of the maximum transmission output 6.1kW, spurious output 69.16dBc, RF pulse rising time 15.2ns and RF pulse falling time 16.3ns. The experiment confirmed the change of output power according to the graceful degradation due to fault injection.

Effects of loading conditions on the fatigue failure characteristics in a polycarbonate

  • Okayasu, Mitsuhiro;Yano, Kei;Shiraishi, Tetsuro
    • Advances in materials Research
    • /
    • v.3 no.3
    • /
    • pp.163-174
    • /
    • 2014
  • In this study, fatigue properties and crack growth characteristics of a polycarbonate (PC) were examined during cyclic loading at various mean stress (${\sigma}_{amp}$) and stress amplitude (${\sigma}_{mean}$) conditions. Different S vs. N and da/dN vs. ${\Delta}K$ relations were obtained depending on the loading condition. The higher fatigue strength and the higher resistance of crack growth are seen for the PC samples cyclically loaded at the higher mean stress and lower stress amplitude due to the low crack driving force. Non-linear S - N relationship was detected in the examination of the fatigue properties with changing the mean stress. This is attributed to the different crack growth rate (longer fatigue life): the sample loaded at the high mean stress with lower stress amplitude. Even if the higher stress amplitude, the low fatigue properties are obtained for the sample loaded at the higher mean stress. This was due to the accumulated strain energy to the sample, where severe plastic deformation occurs instead of crack growth (plasticity-induced crack closure). Shear bands and discontinuous crack growth band (DGB) are observed clearly on the fracture surfaces of the sample cyclically loaded at the high stress amplitude, where the lower the ${\sigma}_{mean}$, the narrower the shear band and DGB. On the other hand, final fracture occurred instantly immediately after the short crack growth occurs in the PC sample loaded at the high mean with the low ${\sigma}_{amp}$, i.e., tear fracture, in which the shear bands and DGB are not seen clearly.

A Cross-layer Link Adaptive HD Video Transmission Scheme in WiMedia D-MAC based UWB Systems

  • Joo, Yang-Ick
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.12
    • /
    • pp.1464-1474
    • /
    • 2012
  • In this paper, we propose a QoS (Quality of Service)-aware and cooperative resource reservation scheme using cross-layer link adaptation for wireless high definition video transmission through UWB (Ultra Wide Band) network with D-MAC (Distributed Medium Access Control). A wireless high definition video transmission system usually requires stable high throughput even without line-of-sight, e.g., a destination device in another room separated by a wall. Since the WiMedia D-MAC supporting DRP (Distributed Reservation Protocol) scheme causes lots of DRP resource reservation conflicts due to failure of beacon detection in wireless channel environment, overall performances of the WiMedia D-MAC can be deteriorated. And the current WiMedia MAC standard has not considered QoS provisioning even though QoS parameters such as a range of service rates are provided to each traffic stream. Therefore, we propose Relay DRP protocol with QoS-based relay node selection criterion, which makes a relay path to avoid DRP resource reservation conflicts and guarantee QoS more stably through cross-layer link adaptation of cooperative relay transmission scheme and is compliant with the current WiMedia D-MAC protocol. Simulation results demonstrate performance improvements of the proposed method for throughput and QoS provisioning.

Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header (주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.