• Title/Summary/Keyword: balance of power

Search Result 1,145, Processing Time 0.028 seconds

Analysis of Nigeria Research Reactor-1 Thermal Power Calibration Methods

  • Agbo, Sunday Arome;Ahmed, Yusuf Aminu;Ewa, Ita Okon Bassey;Jibrin, Yahaya
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.673-683
    • /
    • 2016
  • This paper analyzes the accuracy of the methods used in calibrating the thermal power of Nigeria Research Reactor-1 (NIRR-1), a low-power miniature neutron source reactor located at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria, Nigeria. The calibration was performed at three different power levels: low power (3.6 kW), half power (15 kW), and full power (30 kW). Two methods were used in the calibration, namely, slope and heat balance methods. The thermal power obtained by the heat balance method at low power, half power, and full power was $3.7{\pm}0.2kW$, $15.2{\pm}1.2kW$, and $30.7{\pm}2.5kW$, respectively. The thermal power obtained by the slope method at half power and full power was $15.8{\pm}0.7kW$ and $30.2{\pm}1.5kW$, respectively. It was observed that the slope method is more accurate with deviations of 4% and 5% for calibrations at half and full power, respectively, although the linear fit (slope method) on average temperature-rising rates during the thermal power calibration procedure at low power (3.6 kW) is not fitting. As such, the slope method of power calibration is not suitable at lower power for NIRR-1.

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.

A Study on Power Balance Control for Photovoltaic/Wind/Diesel Hybrid Generation (태양광.풍력.디젤 복합발전을 위한 전력균형제어에 관한 연구)

  • Jeong, S.H.;Cho, J.S.;Gho, J.S.;Choe, G.H.;Kim, E.S.;Lee, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1388-1390
    • /
    • 2002
  • Hybrid power system has a power balanced controller to equilibrate generation power with a load demand and it is composed of DC bus-type power systems. And all of power generators in hybrid power system can be equivalent to current-source characteristics. So this paper discusses power balance control for photovoltaic/wind/diesel hybrid power system. And through the results of simulation, the proposed scheme was verified.

  • PDF

Residual Power based Routing Protocol to Extend Network Lifetime in Wireless Sensor Networks (무선센서네트워크에서 네트워크 수명연장을 위한 잔여전력 기반 라우팅 프로토콜)

  • Won, Jongho;Park, Hyung-Kun
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.5
    • /
    • pp.592-598
    • /
    • 2018
  • In wireless sensor networks where there is no centralized base station, each node has limited transmission range and the multi-hop routing for transmitting data to the destination is the one of the important technical issues. In particular, the wireless sensor network is not powered by external power source but operates by its own battery, so it is required to maximize the network life through efficient use of energy. To balance the power consumption, the residual power based adaptive power control is required in routing protocol. In this paper, we propose a routing protocol that prolongs the network lifetime by balancing the power consumption among the nodes by controlling the transmit power according to the residual power. We evaluate the proposed routing protocol using extensive simulation, and the results show that the proposed routing scheme can balance the power consumption and prolong network lifetime.

Evaluation of Heat Balance for Cooling System of an Armored Installation in Small Space (좁은 공간 내의 밀폐형 장치 냉각시스템에 대한 열평형 평가)

  • Kim, Sung-Kwang;Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.3 s.76
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the heat balance test of an engine was conducted, and the heat released to coolant is measured and corrected using a power adjustment factor for high fuel temperature to simulate heat rejection of the engine. An engine-converter matching simulation program which can compute the engine speed, transmission output speed, transmission input and output power is developed from the vehicle, transmission and engine performance curve. With this information and the engine heat rejection characteristics, the engine and transmission heat rejection rates can be determined at given condition. In analyzing the air mass flow, a sub program computing the air mass flow rate from the equation of the pressure balance between cooling fan static pressure rise and pressure losses of cooling components is developed.

An Interleaved Five-level Boost Converter with Voltage-Balance Control

  • Chen, Jianfei;Hou, Shiying;Deng, Fujin;Chen, Zhe;Li, Jian
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1735-1742
    • /
    • 2016
  • This paper proposes an interleaved five-level boost converter based on a switched-capacitor network. The operating principle of the converter under the CCM mode is analyzed. A high voltage gain, low component stress, small input current ripple, and self-balancing function for the capacitor voltages in the switched-capacitor networks are achieved. In addition, a three-loop control strategy including an outer voltage loop, an inner current loop and a voltage-balance loop has been researched to achieve good performances and voltage-balance effect. An experimental study has been done to verify the correctness and feasibility of the proposed converter and control strategy.

Research on Carried-Based PWM with Zero-Sequence Component Injection for Vienna Type Rectifiers

  • Ma, Hui;Feng, Mao;Tian, Yu;Chen, Xi
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.560-568
    • /
    • 2019
  • This paper studies the inherent relationship between currents and zero-sequence components. Then a precise algorithm is proposed to calculate the injected zero-sequence component to control the DC-Link neutral-point voltage balance, which can result in a more efficient and flexible neutral point voltage balance with a desirable performance. In addition, it is shown that carried-based PWM with the calculated zero-sequence component scheme can be equivalent to space-vector pulse-width modulation (SVPWM). Based on the proposed method, the optimal zero-sequence component of the feasible modulation indices is analyzed. In addition, the unbalanced load limitation of the DC-Link neutral-point voltage balance control is also revealed. Simulation and experimental results are shown to verify the validity and practicality of the proposed algorithm.

Life Cycle Assessment for the Business Activities of Green Company -2. Mass Balance and Environmental Improvement (녹색기업의 사업활동 전 과정에 대한 환경성 평가 -2. 물질수지 및 환경개선)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.425-433
    • /
    • 2013
  • A mass balance of process was calculated by using the analysis of basic unit and environmental assessment of all the processes of Busan fashion color industry cooperative that operates a combined heat and power plant and a bio treatment plant. The mass balance for the combined heat and power plant was done, based on boiler and water treatment processes while each unit reactor was used for the bio treatment plant. From the results above, a resource recycle network, a treatment flowchart for food waste water/wastewater treatment and a carbon reduction program were established.

Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler (발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2020
  • In this study, a multi-zone furnace analysis method that couples a 1D energy and mass balance calculation with a 3D radiative heat transfer calculation is tested in order to verify its reliability. The calculated results for a domestic 500 MW capacity coal-fired boiler furnace were compared with the design data of the boiler manufacturer and CFD analysis, and a good agreement was achieved. Although this calculation method is less sophisticated than the CFD furnace analysis, it has an advantage in terms of calculation time while being able to provide the furnace behavior according to the fuel characteristics and operational variable changes. Therefore, it is expected to be useful for boiler operation diagnosis and daily fuel/operation planning.

Sequence Pulse Modulation for Voltage Balance in a Cascaded H-Bridge Rectifier

  • Peng, Xu;He, Xiaoqiong;Han, Pengcheng;Lin, Xiaolan;Shu, Zeliang;Gao, Shibin
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.664-673
    • /
    • 2017
  • With the development of multilevel converters, cascaded single-phase H-bridge rectifiers (CHBRs) has become widely adopted in high-voltage high-power applications. In this study, sequence pulse modulation (SPM) is proposed for CHBRs. SPM is designed to balance the dc-link voltage and maintain the smooth changes of switch states. In contrast to phase disposition modulation, SPM balances the dc-link voltage even after removing the load of one submodule. The operation principle of SPM is deduced, and the unbalance degree of SPM is analyzed. All the proposed approaches are experimentally verified through a prototype of a four-module (nine-level) CHBR. Conclusions are drawn in accordance with the results of SPM and its imbalance degree analysis.