• 제목/요약/키워드: back stress

검색결과 614건 처리시간 0.029초

전동차 출입문 구동을 위한 SRM용 C-dump 컨버터 Topology 특성 비교 (Characteristic Analysis of C-dump Converter Topology for SRM of Electric Multiple Unit Door Driving)

  • 윤용호
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1597-1604
    • /
    • 2016
  • The speed at which the SRM (Switched Reluctance Motor) makes a transition from chopping control to single pulse operation. (i.e., low speed to high speed operation). It is unsatisfied with performance at all operational regimes. In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on energy efficient C-dump converter topology and the proposed resonant C-dump converter topology. Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

쪼그려 앉은 작업자세에서의 작업부하 평가 (Workload Evaluation of Squatting Work Postures)

  • 이인석;정민근
    • 대한산업공학회지
    • /
    • 제24권2호
    • /
    • pp.167-173
    • /
    • 1998
  • Many workers like welders work in squatting postures with the object on the ground during an entire work shift. It is suspected that such prolonged squatting without any supporting stool would gradually cause musculoskeletal injuries to workers. This study is to examine the physical stress caused by the prolonged squatting and to recommend a safe work/rest schedule for a welding task with squatting posture based on the lab experiments. In this study, 8 healthy student subjects participated in the experiment. They maintained a squatting work posture for 16 minutes with 4 different stool height conditions: no stool; 10cm height; 15cm height; and 20cm height. Every 2 minutes, the discomfort was subjectively assessed with the magnitude estimation method for the whole body, lower back, upper leg and lower leg. Based on discomfort ratings, we found that a 10cm height stool relieved the workload most. Discomfort rating results also indicated that a 20cm height stool showed the highest workload, and the there were no difference in workload between a 15cm height stool and no stool. We recommend to use low height stools and to maintain such working postures no longer than 6 minutes for prolonged squatting tasks.

  • PDF

공작물 적재를 위한 자동정렬 및 적재장치의 설계 및 제작 (Design and Fabrication of an Automatic Alignment and Loading System for Workpieces)

  • 이재경;최명철;김갑순
    • 한국기계가공학회지
    • /
    • 제17권3호
    • /
    • pp.134-140
    • /
    • 2018
  • This paper describes the design and fabrication of an automatic alignment and loading system for workpieces. To move a workpiece to a chucking position of a machine tool using a gantry robot, an automatic aligning device is required to load the workpiece before machining and automatically align them. The automatic alignment system was conceptually designed, and the structural analysis was performed for the main parts such as the top plate, center support, front and back support, and support shaft. Based on the structural analysis results, the size of these structures was determined. The automatic alignment system was manufactured, and the vertical movement characteristics of the workpiece up-and-down movement device and the rotation characteristics of the workpiece rotation device were experimentally examined. The result has confirmed that they operate normally.

Numerical modeling of dynamic compaction process in dry sands considering critical distance from adjacent structures

  • Pourjenabia, Majid;Hamidi, Amir
    • Structural Engineering and Mechanics
    • /
    • 제56권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Dynamic compaction (DC) is a useful method for improvement of granular soils. The method is based on falling a tamper (weighting 5 to 40 ton) from the height of 15 to 30 meters on loose soil that results in stress distribution, vibration of soil particles and desirable compaction of the soil. Propagation of the waves during tamping affects adjacent structures and causes structural damage or loss of performance. Therefore, determination of the safe or critical distance from tamping point to prevent structural hazards is necessary. According to FHWA, the critical distance is defined as the limit of a particle velocity of 76 mm/s. In present study, the ABAQUS software was used for numerical modeling of DC process and determination of the safe distance based on particle velocity criterion. Different variables like alluvium depth, relative density, and impact energy were considered in finite element modeling. It was concluded that for alluvium depths less than 10 m, reflection of the body waves from lower boundaries back to the soil and resonance phenomenon increases the critical distance. However, the critical distance decreases for alluvium depths more than 10 m. Moreover, it was observed that relative density of the alluvium does not significantly influence the critical distance value.

여성결혼이민자를 위한 건강증진 프로그램 개발 및 적용 (Development and Application of a Health Promotion Program for Marriage Immigrant Women)

  • 서인주;박정숙
    • 성인간호학회지
    • /
    • 제27권2호
    • /
    • pp.198-210
    • /
    • 2015
  • Purpose: This study was to develop a health promotion program for marriage immigrant women and to evaluate its efficacy. Methods: The health promotion program was comprised of eight 100-minute weekly sessions. Each session included understanding of health responsibility, nutrition, physical activity, interpersonal relations, stress management, and self actualization. The research was conducted under the principles of nonequivalent control group pretest-post test design. The outcome variables were health promoting behavior, health status, acculturation, self efficacy, and perceived barrier. The participants were 15 immigrant women in the experimental group and 16 in the control group. Data was analyzed using ${\chi}^2$ test, Fisher's exact test, Mann Whitney U-test and Wilcoxon signed rank test. Results: There was a significant improvement in health promoting behaviors (U=-3.08, p=.002), left shoulder flexibility (U=-3.02, p=.003), right shoulder flexibility (U=-3.02, p=.003), low back flexibility (U=-3.37, p=.001), social health status (U=-3.38 p=.001) and subjective health status (U=-2.17 p=.030) in the experimental group compared to the control group. Conclusion: The health promotion program for marriage immigrant women was an effective intervention for improving health promoting behavior, physical health status, social health, and subjective health status. Therefore, the developed health promotion program needs to be applied to married immigrant women in other kinds nursing care settings in future research.

공진형 C-dump컨버터에 의한 SRM의 고성능 운전 (High performance operation of SRM by Resonant C-dump Converter)

  • 정균하;윤용호;김세주;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.28-32
    • /
    • 2004
  • In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on conventional C-dump converter topology and the proposed resonant C-dump converter topology Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

  • PDF

브러시리스 DC 모터의 영구자석 형상에 따른 특성 연구 (The Research on the Characteristics of Brush less DC Motor according to the Shape of the Permanent Magnet)

  • 박찬;김용현;이종찬;전연도;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.840-842
    • /
    • 2001
  • The cogging torque and torque ripple in motor which cause noise and vibration are an inevitable phenomenon and they give a bad effect to motor performance. So we are required to reduce the cogging torque and torque ripple not by electrical controlling but by changing the inner mechanical structure and we focused on the permanent magnet. In this research, we calculated current, torque, Back-EMF(electromotive force) and cogging torque according to the change of the magnet shape using two dimensional FEM(Finite Element Method). Maxwell stress tensor and time-stepping method. From the results, we present an appropriate model that can satisfy both low cogging torque, low torque ripple and high efficiency.

  • PDF

Reliability and Validity of the Greek Version of the Job Content Questionnaire in Greek Health Care Workers

  • Alexopoulos, Evangelos C.;Argyriou, Evangelia;Bourna, Virginia;Bakoyannis, Giorgos
    • Safety and Health at Work
    • /
    • 제6권3호
    • /
    • pp.233-239
    • /
    • 2015
  • Background: The Job Content Questionnaire (JCQ), which is based on the Demand-Control-Support model, is designed to measure the psychosocial characteristics of the respondent's work, and has been identified to predict health and psychological outcomes. The purpose of this study was to investigate the psychometric properties of this instrument and the subsequent adaptation of its scales to the population of Greek health workers. Methods: The Greek version of the JCQ was developed by using forward- and back-translation in accordance with the JCQ policy. The reliability and validity of the measure were investigated in a sample of health workers working in a hospital in Athens, Greece. The internal consistency of the scales was examined based on Cronbach ${\alpha}$ coefficients, and the validity was evaluated subjecting the items of the three main scales of the JCQ (decision latitude, psychological job demands, and social support) to exploratory and confirmatory factor analysis. Results: The reliability of the scales was found to be acceptable for all the scales, except for the skill discretion subscale. Confirmatory factor analysis confirmed a slightly modified version of the original construct including several items to more than one factor. Conclusion: Our findings suggest that the Greek JCQ is reliable and valid for investigating psychosocial job characteristics among Greek health workers.

Ergonomic Problems and Their Improving Measures in Office Environment of General Hospitals

  • Kee, Dohyung
    • 대한인간공학회지
    • /
    • 제34권2호
    • /
    • pp.135-143
    • /
    • 2015
  • Objective: The purposes of this study are to investigate ergonomic problems and to propose their improving measures in office environment of big general hospitals. Background: Office tasks have varying risk factors of work-related musculoskeletal disorders (WMSDs). The first symptom resulted from the office work was recognized as an occupational disease in Korea in 1986. Although the symptoms have increased since its first recognition, there has been few study on the effect of office work environment settings. Method: First, the author took pictures of working scenes performed in three big university hospitals. Next, the pictures were analyzed in view point of ergonomics. Based on the analysis, their improving measures were proposed for reducing work stress. Results: The results showed that most physical office environment settings such as dimensions of tables/desks and chairs, leg room, thigh, knee and foot clearances, and chairs used did not satisfy the ergonomically recommended design guidelines. In addition, some clerks placed personal belongings under their desks, put monitors in high position and did not lean against the backrest of chairs in seated tasks, which resulted in poor working postures of leg, back, neck etc. It is recommended that the hospital management should provide their clerks with ergonomically designed office furniture and continuously perform ergonomics training program for raising clerks' recognition for office ergonomics. Conclusion: Most office environment settings investigated in this study were not in good condition in view point of ergonomic design for the settings. Application: It would be useful as basic data for establishing ergonomically good office environment in hospitals.

Multiloop Edgewise Arch Wire의 역학적 해석 (MECHANICAL ANALYSIS ON THE MULTILOOP EDGEWISE ARCH WIRE)

  • 전경민;남동석
    • 대한치과교정학회지
    • /
    • 제21권1호
    • /
    • pp.31-51
    • /
    • 1991
  • This study was designed to survey the stress distributions and deflections which were derived from MEAW by the computer-aided three dimensional finite element analysis of teeth and surrounding bone composed of 2839 solid elements and 4621 nodes. MEAW model was also made using the 90 beam elements and the results were expressed by quantitative and visible ways. The findings of this study were as follows. 1 In case of vertical load on the MEAW there were extrusions of anterior teeth and upright effects of the posterior teeth. 2. Without applying the vertical elastics on the MEAW there were intrusions of anterior teeth, but relatively mild force was transmitted to the posterior teeth area. Torque forces were observed on the incisors and molars, and canine was intruded without torque. 3. The magnitudes of forces were different by the amounts of tip back bends of MEAW. 4. The displacements were in inverse proportion to the cross section areas of the wires according to the experiment using the 5 different size arch wires. 5. The difference of deflections between the MEAW and plain arch wire was not so big as the theoretical one but the deflections of MEAW were much more than the plain arch wire in every X, Y, Z direction.

  • PDF