• Title/Summary/Keyword: axis alignment

Search Result 234, Processing Time 0.021 seconds

A Study on the Tower type Fizeau Interferometer System with a Fold Minor for Measuring Large Optical Lens Profile (반사경 측정을 위한 타워 방식의 Fold Mirror를 이용한 Fizeau 간섭계 시스템 구성)

  • Lee, Eung-Suk;Lee, Ki-Am;Kim, Ok-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.21-28
    • /
    • 2008
  • Fizeau interferometer is used for inspecting the lens surface profile accurately. This study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for large area lithography or astronomical purpose. A tower type Fizeau interferometer is designed and set up in horizontally with a 45$^{\circ}$ fold mirror which makes easy to align the optical path of heavy interferometer system. To align the optical path, a five-axes stage for the interferometer is required. This study shows a method of the 45$^{\circ}$ fold mirror alignment by using a three-axis stage instead of adjusting the interferometer itself or measuring object. This system will be installed on the large optics polishing machine during the manufacturing process as an on-machine inspection system.

Morphological evolution of ZnO nanowires using varioussubstrates

  • Kar, J.P.;DAS, S.N.;Choi, J.H.;Myoung, J.M.
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.27.1-27.1
    • /
    • 2009
  • In recent years, ZnO nanostructures have drawn considerable attentions for the development of futuristic electronic devices due to their superior structural and optical properties. As the growth of ZnO nanowires by MOCVD is a bottom-up technique, the nature of substrates has a vital role for the dimension and alignment of the nanowires. However, in the pursuit of next generation ZnO based nanodevices, it would be highly preferred if well-ordered ZnO nanowires could be obtained on various substrates like sapphire, silicon, glass etc. Vertically aligned nanowires were grown on A and C-plane sapphire substrates, where as nanopencils were obtained on R-plane sapphire substrates. In addition, C-axis oriented vertical nanowires were also found using an interfacial layer(aluminum nitride film) on silicon substrates. On the other hand, long nanowires were found on Ga-doped ZnO film on glass substrates. Structural and optical properties of the ZnO nanowires on various substrates were also investigated.

  • PDF

An Experiment about Assembling Condition of Carbon Nanotube Tip for AFM (주사탐침현미경용 카본나노튜브 팁의 조립 조건 실험)

  • 박준기;한창수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.501-504
    • /
    • 2004
  • This paper describes the fabrication method for atomic force microscopy(AFM) tip with multi-walled carbon nanotube(MWNT). For making a carbon nanotube (CNT) modified tips, AC electric field which cause the dielectrophoresis was used for alignment and deposition of CNTs in this research. By dropping the MWNT solution and applying an electric field between an AFM tip and an electrode, MWNTs which were dispersed into a diluted solution were directly assembled onto the apex of the AFM tips due to the attraction by the dielectrophoretic force. In this case, we investigate the effect of the angle between a tip axis and an electrode. Experimental setup were presented, and then CNT attached AFM tips are successfully shown in this paper.

  • PDF

Optimal Control for Proximity Operations and Docking

  • Lee, Dae-Ro;Pernicka, Henry
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.3
    • /
    • pp.206-220
    • /
    • 2010
  • This paper proposes optimal control techniques for determining translational and rotational maneuvers that facilitate proximity operations and docking. Two candidate controllers that provide translational motion are compared. A state-dependent Riccati equation controller is formulated from nonlinear relative motion dynamics, and a linear quadratic tracking controller is formulated from linearized relative motion. A linear quadratic Gaussian controller using star trackers to provide quaternion measurements is designed for precision attitude maneuvering. The attitude maneuvers are evaluated for different final axis alignment geometries that depend on the approach distance. A six degrees-of-freedom simulation demonstrates that the controllers successfully perform proximity operations that meet the conditions for docking.

Correction of mass imbalance of a high precision rotor (Impact를 이용한 정밀 고속 회전체 불평형 보정)

  • Lee, S.B.;Ihn, Y.S.;Oh, D.H.;Kim, H.Y.;Lee, H.S.;Koo, J.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.843-847
    • /
    • 2007
  • The unbalanced mass of a high precision rotor deteriorates mechanical performance of the rotor. The geometrical center of a rotor generally corresponds to the rotational axis of the rotor. However, this alignment carried out with a stationary rotor does not guarantee the dynamic rotor balance. There have been a number of schemes for the correction of the imbalance published for decades especially in the hard drive industry where the issues are directly affecting manufacturing costs and product performances. Realizing the significance of the problem, the present work tries to refine one of the methods that works by applying external impact during a rotor spins. A systematic way to apply the external impact to a rotating rotor has been introduced to minimize imbalance correction process time.

  • PDF

Fabricating and Observing Electric Conducting Phenomena Called "Anisotropy" of Organic Ultra Thin Films with (N-docosyl pyridinium)-TCNQ(1:2)Complex by the Langmuir-Blodgett Method (Langmuir-Blodgett(LB)법을 이용한 (N-docosyl pyridinium)-TCNQ(1:2)착체 유기 초박막의 제작과 이방성 전기전도 현상)

  • Kang, Hun;Jeong, Soon-Wook;Lee, Won-Jae;Shon, Byoung-Chung;Kang, Dou-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.175-178
    • /
    • 1988
  • A film is fabricated by depositing several sliced organic ultra thin films on a slide glass. Both UV-absorbance and the capacitance of a multi - layered organic ultra thin film with (N-docosyl pyridinium)-TCNQ(1:2) complex have a desired value on the condition of well alignment in depositing several layers. Forethermore the conductivity of this film measured by the direction of either horizontal or vertical axis. respectively, is results in a quite different value.

  • PDF

Array of 2-dimensions and Vertical Alignment of Zinc Oxide Micro Rod by the CBD Method (CBD법에 위한 ZnO 마이크로 막대 구조체의 2차원 배열 및 수직정렬)

  • Lee, Yeok-Kyoo;Nam, Hyo-Duk;Lee, Sang-Hwan;Jeon, Chan-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.682-688
    • /
    • 2009
  • A periodic away of zinc oxide(ZnO) micro-rods as fabricated by using chemical bath deposition and photo-lithography. Vertically aligned ZnO micro-rods array was successfully grown by chemical bath deposition method on ZnO seed layer. The ZnO seed layer was deposited on glass and the patterning was made by standard photo-lithography technique. The selective growth of ZnO micro-rods as achieved with the masked ZnO seed layer. The fabricated ZnO micro rods were found to be single crystalline and have grown along hexagonal c-axis direction of (0002) which is same as the preferred growth orientation of ZnO seed layer.

Supramalleolar Osteotomy for Moderate Degenerative Ankle Osteoarthritis (중등도 퇴행성 족관절염에 대한 과상부 경골 절골술의 술기)

  • Kang, Jung Mo;Lee, Myoung Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.122-127
    • /
    • 2017
  • This paper reviews the indications and surgical technique of supramalleolar osteotomy as one of the treatments for moderate degenerative ankle osteoarthritis. Although it is technically demanding and requires extensive preoperative planning, supramalleolar osteotomy will be a good treatment option for moderate degenerative ankle osteoarthritis. The osteotomy is designed to shift the weight bearing axis to the lateral side of the ankle joint and unload the medial side of the joint. In our experience, a supramalleolar osteotomy is effective to the treatment of moderate ankle osteoarthritis with a small amount of preoperative talar tilt and varus or normal heel alignment.

Design of the precision micro-positioning stage (초정밀 마이크로 위치결정 스테이지의 설계)

  • 한창수;김경호;이찬홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.539-542
    • /
    • 1997
  • We present a micro-positioning stage that has minimized geometrical error and can drive in the 4-axis. This stage divided into two parts: $Z\theta_x$ $\theta_y$, motion stage and$\theta_z$ motion stage. These stages are constructed in flexure hinges, piezoelectric actuators and displacement scnsors. The dynamic model for each stage is obtained and their FE (finite element) models are made. Using the Lagrange's equation, the motion of equation is found. Through the parametric analysis and FE analysis, sensitiv~ty of the design parameters is executed. Finally, fundamental frequencies, maximum stress, and displacement sensitivity for each stage are obtained. We expect that this micro-positioning stage be a useful micro-alignment device for various applications.

  • PDF

Correction of Mass Unbalance of a High Precision Rotor (Impact를 이용한 정밀 고속 회전체 불평형 보정)

  • Lee, S.B.;Ihn, Y.S.;Oh, D.H.;Kim, H.Y.;Lee, H.S.;Koo, J.C.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.720-725
    • /
    • 2007
  • The unbalanced mass of a high precision rotor deteriorates mechanical performance of the rotor. The geometrical center of a rotor generally corresponds to the rotational axis of the rotor. However, this alignment carried out with a stationary rotor does not guarantee the dynamic rotor balance. There have been a number of schemes for the correction of the unbalance published for decades especially in the hard drive industry where the issues are directly affecting manufacturing costs and product performances. Realizing the significance of the problem, the present work tries to refine one of the methods that works by applying external impact during a rotor spins. A systematic way to apply the external impact to a rotating rotor has been introduced to minimize unbalance correction process time.