• Title/Summary/Keyword: axis alignment

Search Result 234, Processing Time 0.023 seconds

Mirrors and Optomechanical Structures Design and Analysis for Linear Astigma-tism Free Three Mirror System (LAF-TMS)

  • Park, Woojin;Hammar, Arvid;Lee, Sunwoo;Chang, Seunghyuk;Kim, Sanghyuk;Jeong, Byeongjoon;Kim, Geon Hee;Kim, Daewook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.55.4-56
    • /
    • 2018
  • Linear Astigmatism Free - Three Mirror System (LAF-TMS) is the linear astigmatism free off-axis wide field telescope with D = 150 mm, F/3.3, and $FOV=5.51^{\circ}{\times}4.13^{\circ}$. We report the design and analysis results of its mirrors and optomechanical structures. Tolerance allowance has been analyzed to the minimum mechanical tolerance of ${\pm}0.05mm$ that is reasonable tolerance for fabrication and optical alignment. The aluminum mirrors are designed with mounting flexure features for the strain-free mounting. From Finite Element Analysis (FEA) results of mounting torque and self-weight, we expect 33 - 80 nm RMS mirror surface deformations. Shims and the L-bracket are mounted between mirrors and the mirror mount for optical alignment. The mirror mount is designed with four light-weighted mechanical parts. It can stably and accurately fix mirrors, and it also suppresses some of stray light.

  • PDF

Physical Origin of the Planar Alignment of Satellite Galaxies

  • Seo, Chanoul;Paudel, Sanjaya;Yoon, Suk-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.33.3-34
    • /
    • 2020
  • The Milky Way (MW) and other systems including M31 and Cen A have flattened structures of their satellites (Disk of Satellites, DoS). Such structures are rare in simulations under the ΛCDM paradigm. DoS is known to depend mainly on 1) the alignment of satellite orbits and 2) the degree of central concentration of satellites. In this work, we examine quantitatively how these two parameters affect the flatness of a system. We find that the MW-like DoS is rare in IllustrisTNG100 simulation because its two parameters are out of the 1-s range and furthermore the MW has a structure more flattened than the other systems having similar parameters. Besides, we propose a new criterion for the MW-like systems superseding the conventional ones such as major-minor axis ratio of the MW's DoS with a value of 0.183. Each satellite system has a specific orbital combination and thus has a particular distribution of its parameters (and thus flatness). The median of the distribution is set as the representative value of each system. And the representative value of the MW can be used as a new criterion for classifying the MW-like DoS. We reconstruct the orbital combination of the observed MW satellites using GAIA DR2 data and find the systems in the simulation that have representative values similar to the new criterion from the reconstructed MW system. This allows us a new interpretation on the rarity of MW-like DoS in cosmological simulations.

  • PDF

Comparison of Sagittal Spinopelvic Alignment between Lumbar Degenerative Spondylolisthesis and Degenerative Spinal Stenosis

  • Lim, Jae Kwan;Kim, Sung Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.6
    • /
    • pp.331-336
    • /
    • 2014
  • Objective : The purpose of this study was to evaluate the differences in sagittal spinopelvic alignment between lumbar degenerative spondylolisthesis (DSPL) and degenerative spinal stenosis (DSS). Methods : Seventy patients with DSPL and 72 patients with DSS who were treated with lumbar interbody fusion surgery were included in this study. The following spinopelvic parameters were measured on whole spine lateral radiographs in a standing position : pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS), lumbar lordosis angle (LL), L4-S1 segmental lumbar angle (SLL), thoracic kyphosis (TK), and sagittal vertical axis from the C7 plumb line (SVA). Two groups were subdivided by SVA value, respectively. Normal SVA subgroup and positive SVA subgroup were divided as SVA value (<50 mm and ${\geq}50mm$). Spinopelvic parameters/PI ratios were assessed and compared between the groups. Results : The PI of DSPL was significantly greater than that of DSS (p=0.000). The SVA of DSPL was significantly greater than that of DSS (p=0.001). In sub-group analysis between the positive (34.3%) and normal SVA (65.7%), there were significant differences in LL/PI and SLL/PI (p<0.05) in the DSPL group. In sub-group analysis between the positive (12.5%) and normal SVA (87.5%), there were significant differences in PT/PI, SS/PI, LL/PI and SLL/PI ratios (p<0.05) in the DSS group. Conclusion : Patients with lumbar degenerative spondylolisthesis have the propensity for sagittal imbalance and higher pelvic incidence compared with those with degenerative spinal stenosis. Sagittal imbalance in patients with DSPL is significantly correlated with the loss of lumbar lordosis, especially loss of segmental lumbar lordosis.

An AFM-based Edge Profile Measuring Instrument for Diamond Cutting Tools

  • Asai, Takemi;Motoki, Takenori;Gao, Wei;Ju, Bing-Feng;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.54-58
    • /
    • 2007
  • This paper describes an atomic force microscope (AFM)-based instrument for measuring the nanoscale cutting edge profiles of diamond cutting tools. The instrument consists of a combined AFM unit and an optical sensor to align the AFM tip with the top of the diamond cutting tool edge over a submicron range. In the optical sensor, a aser beam is emitted from a laser diode along the Y-axis and focused to a small beam spot with a diameter of approximately $10{\mu}m$ at the beam waist, which is then received by a photodiode. The top of the tool edge is first brought into the center of the beam waist by adjusting it in the X-Z-plane while monitoring the variation in the photodiode output. The cutting tool is then withdrawn and its top edge position at the beam center is recorded. The AFM tip can also be positioned at the beam center in a similar manner to align it with the top of the cutting edge. To reduce electronic noise interference on the photodiode output and thereby enhance the alignment accuracy, a technique is applied that can modulate the photodiode output to an AC signal by driving the laser diode with a sinusoidal current. Alignment experiments and edge profile measurements of a diamond cutting tool were carried out to verify the performance of the proposed system.

T1 Slope and Cervical Sagittal Alignment on Cervical CT Radiographs of Asymptomatic Persons

  • Park, Ji Hoon;Cho, Chul Bum;Song, Jun Ho;Kim, Seok Woo;Ha, Yoon;Oh, Jae Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.356-369
    • /
    • 2013
  • Objective : We performed a retrospective analysis of medical records and radiographic images of patients who never underwent spinal treatment including diagnosis. The objective of this study is to explain the biomechanical and physiologic characteristics of cervical alignment related to thoracic inlet angle including T1 slope changes in each individual. Methods : We reviewed the cervical CT radiographs of 80 patients who visited ENT outpatient clinic without any symptom, diagnosis and treatment of cervical spine from January 2011 to September 2012. All targeted people were randomized without any prejudice. We assessed the data-T1 slope, Cobb's angle C2-7, neck tilt, sagittal vertical axis (SVA) C2-7 and thoracic inlet angle by the CT radiographs. Results : The relationships between each value were analyzed and we concluded that Cobb's angle C2-7 gets higher as the T1 slope gets higher, while the SVA C2-7 value decreases. Conclusion : We propose that the T1 slope is background information in deciding how much angle can be made in the cervical spinal angle of surgical lordotic curvature, especially severe cervical deformity.

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.

Preoperative Radiological Parameters to Predict Clinical and Radiological Outcomes after Laminoplasty

  • Lee, Su Hun;Son, Dong Wuk;Shin, Jun Jae;Ha, Yoon;Song, Geun Sung;Lee, Jun Seok;Lee, Sang Weon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.677-692
    • /
    • 2021
  • Many studies have focused on pre-operative sagittal alignment parameters which could predict poor clinical or radiological outcomes after laminoplasty. However, the influx of too many new factors causes confusion. This study reviewed sagittal alignment parameters, predictive of clinical or radiological outcomes, in the literature. Preoperative kyphotic alignment was initially proposed as a predictor of clinical outcomes. The clinical significance of the K-line and K-line variants also has been studied. Sagittal vertical axis, T1 slope (T1s), T1s-cervical lordosis (CL), anterolisthesis, local kyphosis, the longitudinal distance index, and range of motion were proposed to have relationships with clinical outcomes. The relationship between loss of cervical lordosis (LCL) and T1s has been widely studied, but controversy remains. Extension function, the ratio of CL to T1s (CL/T1s), and Sharma classification were recently proposed as LCL predictors. In predicting postoperative kyphosis, T1s cannot predict postoperative kyphosis, but a low CL/T1s ratio was associated with postoperative kyphosis.

A Robotic Vision System for Turbine Blade Cooling Hole Detection

  • Wang, Jianjun;Tang, Qing;Gan, Zhongxue
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.237-240
    • /
    • 2003
  • Gas turbines are extensively used in flight propulsion, electrical power generation, and other industrial applications. During its life span, a turbine blade is taken out periodically for repair and maintenance. This includes re-coating the blade surface and re-drilling the cooling holes/channels. A successful laser re-drilling requires the measurement of a hole within the accuracy of ${\pm}0.15mm$ in position and ${\pm}3^{\circ}$ in orientation. Detection of gas turbine blade/vane cooling hole position and orientation thus becomes a very important step for the vane/blade repair process. The industry is in urgent need of an automated system to fulfill the above task. This paper proposes approaches and algorithms to detect the cooling hole position and orientation by using a vision system mounted on a robot arm. The channel orientation is determined based on the alignment of the vision system with the channel axis. The opening position of the channel is the intersection between the channel axis and the surface around the channel opening. Experimental results have indicated that the concept of cooling hole identification is feasible. It has been shown that the reproducible detection of cooling channel position is with +/- 0.15mm accuracy and cooling channel orientation is with +/$-\;3^{\circ}$ with the current test conditions. Average processing time to search and identify channel position and orientation is less than 1 minute.

  • PDF

A Study on The Measurement and Compensation of Satellite Deflection (위성의 처짐 측정 및 보상에 관한 연구)

  • Moon, Hong-Youl;Kim, Jin-Hee;Woo, Sung-Hyun;Cho, Chang-Lae
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.39-45
    • /
    • 2010
  • Satellites are generally put in horizontal configuration to install a weighty, large and deploying SAR antenna which is required precise alignment. It is not to damage an antenna deployment mechanism from impellent strength as SAR antenna rotation axis is aligned with the gravity axis and SAR antenna is put in a zero gravity condition. In order to install such a deploying antenna, satellite should be a same condition of the vertical configuration without the deflection of satellite when it is rotated horizontally. In this paper, it is shown how to measure the deflection of satellite and how to get a reaction force value for compensating the deflection.

  • PDF

NUMERICAL ANALYSIS OF THE IMPACTING AND SPREADING DYNAMICS OF THE ELLIPSOIDAL DROP ON THE PERFECT NON-WETTING SOLID SURFACE (완전 비습윤 고체 표면 위 타원형 액적의 충돌 및 퍼짐 거동에 대한 수치적 연구)

  • Yun, S.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.90-95
    • /
    • 2016
  • Leidenfrost drops with ellipsoidal shaping can control the bouncing height by adjusting the aspect ratio(AR) of the shape at the moment of impact. In this work, we focus on the effect of the AR and the impact Weber number(We) on the non-axisymmetrical spreading dynamics of the drop, which plays an important role in the control of bouncing. To understand the impact dynamics, the numerical simulation is conducted for the ellipsoidal drop impact upon the perfect non-wetting solid surface by using volume of fluid method, which shows the characteristics of the spreading behavior in each principal axis. As the AR increases, the drop has a high degree of the alignment into one principal axis, which leads to the consequent suppression of bouncing height with shape oscillation. As the We increases, the maximum spreading diameters in the principal axes both increase whereas the contact time on the solid surface rarely depends on the impact velocity at the same AR. The comprehensive understanding of the ellipsoidal drop impact upon non-wetting surface will provide the way to control of drop deposition in applications, such as surface cleaning and spray cooling.