Radiosurgery for Recurrent Brain Metastases after Whole-Brain Radiotherapy : Factors Affecting Radiation-Induced Neurological Dysfunction

  • Gwak, Ho-Shin;Yoo, Hyung-Jun;Youn, Sang-Min;Lee, Dong-Han;Kim, Mi-Sook;Rhee, Chang-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권5호
    • /
    • pp.275-283
    • /
    • 2009
  • Objective : We retrospectively analyzed survival, local control rate, and incidence of radiation toxicities after radiosurgery for recurrent metastatic brain lesions whose initial metastases were treated with whole-brain radiotherapy. Various radiotherapeutical indices were examined to suggest predictors of radiation-related neurological dysfunction. Methods : In 46 patients, total 100 of recurrent metastases (mean 2.2, ranged 1-10) were treated by CyberKnife radiosurgery at average dose of 23.1 Gy in 1 to 3 fractions. The median prior radiation dose was 32.7 Gy, the median time since radiation was 5.0 months, and the mean tumor volume was $12.4cm^3$. Side effects were expressed in terms of radiation therapy oncology group (RTOG) neurotoxicity criteria. Results : Mass reduction was observed in 30 patients (65%) on MRI. After the salvage treatment, one-year progression-free survival rate was 57% and median survival was 10 months. Age(<60 years) and tumor volume affected survival rate(p=0.03, each). Acute (${\leq}$1 month) toxicity was observed in 22% of patients, subacute and chronic (>6 months) toxicity occurred in 21 %, respectively. Less acute toxicity was observed with small tumors (<$10cm^3$. p=0.03), and less chronic toxicity occurred at lower cumulative doses (<100 Gy, p=0.004). "Radiation toxicity factor" (cumulative dose times tumor volume of <1,000 Gy${\times}cm^3$) was a significant predictor of both acute and chronic CNS toxicities. Conclusion: Salvage CyberKnife radiosurgery is effective for recurrent brain metastases in previously irradiated patients, but careful evaluation is advised in patients with large tumors and high cumulative radiation doses to avoid toxicity.

LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석 (Analysis of Local Exposure Levels of Radiation Emitted from Soft X-ray Ionizers in LCD Manufacturing Processes)

  • 김준범;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.342-352
    • /
    • 2021
  • Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics. Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement. Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.

Public Exposure to Natural Radiation and the Associated Increased Risk of Lung Cancer in the Betare-Oya Gold Mining Areas, Eastern Cameroon

  • Joseph Emmanuel Ndjana Nkoulou II;Louis Ngoa Engola;Guy Blanchard Dallou;Saidou;Daniel Bongue;Masahiro Hosoda;Moise Godefroy Kwato Njock;Shinji Tokonami
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.59-67
    • /
    • 2023
  • Background: This study aims to reevaluate natural radiation exposure, following up on our previous study conducted in 2019, and to assess the associated risk of lung cancer to the public residing in the gold mining areas of Betare-Oya, east Cameroon, and its vicinity. Materials and Methods: Gamma-ray spectra collected using a 7.62 cm×7.62 cm in NaI(Tl) scintillation spectrometer during a car-borne survey, in situ measurements and laboratory measurements performed in previous studies were used to determine the outdoor absorbed dose rate in air to evaluate the annual external dose inhaled by the public. For determining internal exposure, radon gas concentrations were measured and used to estimate the inhalation dose while considering the inhalation of radon and its decay products. Results and Discussion: The mean value of the laboratory-measured outdoor gamma dose rate was 47 nGy/hr, which agrees with our previous results (44 nGy/hr) recorded through direct measurements (in situ and car-borne survey). The resulting annual external dose (0.29±0.09 mSv/yr) obtained is similar to that of the previous study (0.33±0.03 mSv/yr). The total inhalation dose resulting from radon isotopes and their decay products ranged between 1.96 and 9.63 mSv/yr with an arithmetic mean of 3.95±1.65 mSv/yr. The resulting excess lung cancer risk was estimated; it ranged from 62 to 216 excess deaths per million persons per year (MPY), 81 to 243 excess deaths per MPY, or 135 excess deaths per MPY, based on whether risk factors reported by the U.S. Environmental Protection Agency, United Nations Scientific Committee on the effects of Atomic Radiation, or International Commission on Radiological Protection were used, respectively. These values are more than double the world average values reported by the same agencies. Conclusion: There is an elevated level of risk of lung cancer from indoor radon in locations close to the Betare-Oya gold mining region in east Cameroon. Therefore, educating the public on the harmful effects of radon exposure and considering some remedial actions for protection against radon and its progenies is necessary.

토모테라피에서 쌀 볼루스 팬텀의 유용성 평가: 팬텀연구 (Evaluating the Usefulness of Rice Bolus Phantom in Tomotherapy: Phantom Study)

  • 김대건;정재홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.663-669
    • /
    • 2021
  • The purpose of this study was to evaluate the usefulness of the rice bolus for upper-lower extremity radiation therapy by Tomotherapy. The computed tomography images were obtained for air, water, and rice bolus. The average and standard deviation of the Hounsfield unit (HU) were measured for image evaluation. The conformity index (CI) and homogeneity index (HI) were calculated for dose distribution of the planning target volume (PTV) which was treated by direct mode with gantry angle (90 and 270 angle). The point dose of a total of ten axial planes was measured to confirm the different regions. The mean of HU was -999.72 ± 0.72 at the air. The water and rice bolus were -0.13 ± 1.65 and -170 ± 27.2, respectively. The CI (HI) of PTV was 0.96 (1.36) at the air. 0.95 (1.04) at the water bolus, and 0.95 (1.04) at the rice bolus. The maximum dose for air was 136 cGy which is about 32% higher than 103 cGy for water and 104 cGy for rice bolus. There was a statistical difference for point dose between air and water including rice bolus (p=0.04), however, no statistical difference between water and rice bolus (p=0.579).The rice bolus phantom for extremities radiation therapy could be not only the optimized dose distribution but also the convenience and equipment safety at Tomotherapy. However, additional research will be necessary to more accurately verify the clinical usefulness of rice bolus phantom due to not enough examination.

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가 (The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography)

  • 김미영;김화선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.293-298
    • /
    • 2012
  • 디지털 유방촬영술은 유방의 두께 및 유선조직의 밀도에 따라 노출조건이 자동으로 이루어지는 자동노출제어장치를 사용하고 있는데 이는 피폭선량을 증가시키는 원인이 되기도 한다. 이 연구에서는 디지털 유방확대촬영술에서 영상의 질을 유지하며 불필요한 방사선 피폭을 줄이기 위한 최적의 방사선량 촬영조건을 알아보았다. 자동노출방식을 사용할 경우 가장 좋은 영상화질을 얻을 수 있었으나 평균유선선량 역시 가장 높았다. 수동노출방식의 경우 자동노출방식의 55 % 정도의 mAs 값만으로도 기준 팬텀영상 점수와 신호대잡음비를 얻을 수 있으며 평균유선선량은 55 % 이하로 줄일 수 있었다. 위와 같은 결과를 참고로 하면 디지털 유방확대촬영 시 자동노출방식보다는 수동노출방식을 이용함으로써 불필요한 환자의 피폭선량을 줄일 수 있을 것이라 생각된다.

한국의 환경방사선준위(環境放射線準位)($1961{\sim}1980$) (Environmental Radiation Level in Korea($1961{\sim}1980$))

  • 노재식
    • Journal of Radiation Protection and Research
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 1981
  • This report presents the results of the environmental radiation program at Korea Advanced Energy Research Institute (KAERI) ($37^{\circ}38'N,\;127^{\circ}05'E$) and its surroundings for the last two decades (January, 1961 through December, 1980). In the 1960s, the monthly mean levels of environmental external radiation encountered ranged from a low of 14.2 microroentgen per hour to a high of 42.2 microroentgen per hour with a mean of 21.7 microroentgen per hour, while in 1970s it ranged from a low of 12.4 microroentgen per hour to a high of 40.8 microroentgen per hour with a mean of 20.4 microroentgen per hour. It may, therefore, be said that environmental radiation dose rates remained almost unchanged for the two decades except for the second half of 1960s and the first half of 1970s during which the off-site and on-site patterns were frequently unlike in form and intensity with appreciable differences between average values. Particular results of interest with respect to the effects of the fallout gamma dose rate on environmental radiation show that elevated levels were encountered in association with the deposits of fresh debris from Chinese and Russian nuclear weapons tests in particular.

  • PDF

변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가 (Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery)

  • 장원석;박광우;신동봉;김종대;김세준;하진숙;전미진;조윤진;정인호
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.7-16
    • /
    • 2016
  • 목 적 : 변형 근치적 유방절제술(modified radical mastectomy, MRM)후 흉벽에 전자선 치료를 받는 환자에게 3D-bolus와 step-bolus를 각각 적용하여 유용성을 비교 평가하였다. 대상 및 방법 : 본 연구는 광자선과 전자선을 이용한 역하키스틱법 방식으로 치료계획이 수립된 총 6명의 유방암 환자를 대상으로 하였다. 전방흉벽에 대한 전자선 처방선량은 회당 180 cGy로 3D 프린터(CubeX, 3D systems, USA)로 제작된 3D-bolus와 본원에서 자체 제작한 기존의 stepbolus를 적용하였다. 3D-bolus와 step-bolus에 대한 표면선량은 GAFCHROMIC EBT3 film (International specialty products, USA)을 이용하여, bolus의 다섯 측정지점(iso-center, lateral, medial, superior, and inferior)에 대한 선량 값을 통해 비교 분석하였다. 또한 3D-bolus와 step-bolus 적용에 따른 치료계획을 각각 수립하여 그 결과를 비교하였다. 결 과 : 표면선량은 3D-bolus 적용 시 평균 179.17 cGy이고 step-bolus는 172.02 cGy였다. 처방선량 180 cGy에 대한 평균 값의 오차율은 3D-bolus 적용 시 -0.47%이고 step-bolus는 -4.43%였다. 측정지점 iso-center에서의 오차율은 3D-bolus 적용 시 최대 2.69%의 차이를 보였고, step-bolus는 5.54%였다. 치료의 오차범위는 step-bolus에서 약 6%이고, 3D-bolus는 약 3%였다. 치료계획을 통해 비교한 흉벽의 평균 표적선량은 0.3%로 큰 차이를 나타내지 않았다. 그러나 폐와 심장의 평균 표적선량은 step-bolus에 비해 3D-bolus에서 -11%와 -8%로 감소하였다. 결 론 : 본 연구 결과로 볼 때 흉벽에 대한 피부표면의 접촉면이 고려된 3D-bolus는 step-bolus에 비하여 환자 피부에 잘 밀착되고, 정밀한 흉벽두께 보상이 가능하기 때문에 선량 균일성이 향상됨을 확인하였다. 또한 흉벽에 대한 선량은 동일하지만 인접장기의 선량을 감소시켜 정상조직을 더 많이 보호함으로써 3D-bolus가 임상적으로 유용한 보상체로 사용될 것으로 사료된다.

  • PDF

체적변조회전치료에서 Hybrid Optimized VMAT Phantom (HOVP)을 이용한 실시간 환자 맞춤형 정도관리를 위한 예비연구 (A Pilot Research for Real-Time Specific Patient Quality Assurance Using the Hybrid Optimized Vmat Phantom (Hovp) in Volume Modulated Arc Therapy)

  • 허현도;최상현;김우철;김헌정;김금배;김성훈;조삼주;민철기;조광환;이상훈;이석;심장보;신동오;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.206-215
    • /
    • 2011
  • 다엽콜리메이터, 겐트리회전, 선량율 등에서 형성되는 플루언스 맵을 이용하여 환자 맞춤형 치료 선량검증이 가능한지 알아보았다. 플루언스 맵은 2D 배열 검출기로 측정하였고, 동일 치료계획을 팬톰 내에서 이온전리함, 필름, 유리선량계 등을 이용하여 측정 비교하였다. 목표점에서 체적감마인자(volume gamma index, 3%, 3 mm)기준에 통과율은 $85.22%{\pm}1.7$(RT_target), $89.96%{\pm}2.15$였고, G4는 $95.14%{\pm}1.18$이었다. 선량 전달 오차는 선량이 급격히 변화는 영역(G1, G2, G3)과 주요장기(G4)에서 각각 $11.72%{\pm}0.531$, $-11.47%{\pm}0.991$, $7.81%{\pm}0.857$, $-4.14%{\pm}0.761$이었다. 이온전리함 측정값의 상대오차는 각각 평균 $-1.02%{\pm}0.222$ (Rt_target), $0.96%{\pm}0.294$ (Lt_target)이었다. 필름의 감마인자(3%, 3 mm) 기준 평균 통과율은 $92.59%{\pm}3.312$이었다. 유리선량계 상대 오차는 8.3% (G1), -5.4% (G2), 7.2% (G3), 6.1% (G4)이었다. 체적변조회전방사선 치료(VMAT)시 실시간 플루언스 맵 측정을 통한 실시간 환자 맞춤형 선량 검증이 가능할 것으로 사료되었다.

Dosimetric Comparison of 6 MV Flattening Filter Free and 6 MV Stereotactic Radiosurgery Beam Using 4 mm Conical Collimator for Trigeminal Neuralgia Radiosurgery

  • Mhatre, Vaibhav R;Chadha, Pranav;Kumar, Abhaya P;Talapatra, Kaustav
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.107-113
    • /
    • 2018
  • Background: The purpose of our study was to compare the dosimetric advantages of Flattening filter free (FFF) beams for trigeminal neuralgia patients using 4 mm conical collimators over previously treated patients with 6 MV SRS beam. Materials and Methods: A retrospective study was conducted for 5 TN patients who had been previously treated at our institution using frame-based, LINAC-based stereotactic radiosurgery (SRS) on Novalis Tx using 6 MV SRS beam were replanned on 6X FFF beams on Edge Linear accelerator with same beam angles and dose constraints using 4 mm conical collimator. The total number of monitor units along with the beam on time was compared for both Edge and Novalis Tx by redelivering the plans in QA mode of LINAC to compare the delivery efficiency. Plan quality was evaluated by homogeneity index (HI) and Paddick gradient index (GI) for each plan. We also analyzed the doses to brainstem and organ at risks (OARs). Results and Discussion: A 28% beam-on time reduction was achieved using 6X FFF when compared with 6X SRS beam of Novalis Tx. A sharp dose fall off with gradient index value of $3.4{\pm}0.27$ for 4 mm Varian conical collimator while $4.17{\pm}0.20$ with BrainLab cone. Among the 5 patients treated with a 4 mm cone, average maximum brainstem dose was 10.24 Gy for Edge using 6X FFF and 14.28 Gy for Novalis Tx using 6X SRS beam. Conclusion: The use of FFF beams improves delivery efficiency and conical collimator reduces dose to OAR's for TN radiosurgery. Further investigation is warranted with larger sample patient data.