• Title/Summary/Keyword: average radiation dose

Search Result 601, Processing Time 0.024 seconds

Neutron dosimetry depending on the number of portals for prostate cancer IMRT(Intensity-Modulated Radiation Therapy) (전립선암의 세기조절 방사선치료 시 조사문수별 중성자선량 평가)

  • Lee, Joo-Ah;Son, Soon-Yong;Min, Jung-Whan;Choi, Kwan-Woo;Na, Sa-Ra;Jeong, Hoi-Woun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3734-3740
    • /
    • 2014
  • The aim of this study was provide basic information and establish the criteria in radiation therapy planning by measuring the absorbed neutron dose of normal tissues and lesions according to the number of portals. From September 2013 to January 2014, 20 patients who were diagnosed with prostate cancer and were previously treated with radiation therapy were replanned retrospectively to measure the absorbed neutron dose distribution according to the number of portals. The absorbed neutron dose was measured in each of the 5, 7 and 9 portals using a 15 MV energy, which meant a therapeutic dose of 220 cGy. The optical stimulation luminescence dosimeter was separated by 20cm and 60cm away from the center of the field of view. As a result, the average radiation dose in the abdomen appeared to have a positive relationship with the number of portals, which was statistically significant (p<.05). The average radiation dose was $4.34{\pm}1.08$. The average radiation dose in the thyroid was $2.71{\pm}.37$. Although it showed a positive relationship with the number of portals, it did not have statistical significance. The number of portals and the neutron dose depending on the position showed a significant positive relationship, particularly in the abdomen. As a result of linear regression analysis, as the number of the portal increased in steps, the average volume of the neutrons increased significantly (0.416 times). In conclusion, efficient selection of the number of portals is needed considering the difference in the absorbed neutron dose in the normal tissues depending on the number of the portals.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Outpatient Radioablation Therapy for Thyroid Cancer Patients with Minimal Radiation Exposure to the Family Members (갑상선암 환자의 방사선옥소 외래치료시 가족 구성원의 방사선량 측정)

  • Park, Hee-Myung;Jang, Jung-Woong;Yang, Hee-Chul;Kim, Young-Gook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.218-225
    • /
    • 2007
  • Purpose: Postoperative thyroid remnant radioablation therapy is necessary to reduce the recurrence and mortality rates as well as to prepare the patients for a proper long term surveillance of well-differentiated thyroid cancers. The radiation safety rules of the government require the patient to be isolated in a hospital if the expected radiation exposure to the family members would be greater than 5 mSv (500 mRem). The purpose was to measure the radiation received by the family members of patients who received large doses of NaI-131. Material and Methods: We have administered 12 therapy doses ranging from 3.70-5.55 GBq (100 to 150 mCi) to 11 patients, and released them immediately if they met the radiation safety criteria. Informed consent was obtained from the subjects prior to the therapy, and each of them agreed to follow written radiation safety instructions. TLD badges were used to measure the radiation dose received by the family members and the room adjacent to the patient's bed room during the first 72 hours. Results: The average dose received by the family members who spent the most time in the closest distance with the patients was 0.04 mSv with a range of 0.01-0.17 mSv. Even the highest dose was only about 3% of the limit set by the government. The average radiation dose to the outer wall of the patient's room was 0.15 mSv. Conclusion: It is concluded that I-131 ablation therapy can be administered to outpatients safely to thyroid cancer patients who meet the established radiation safety criteria and follow the instructions.

Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment (인터벤션 방사선발생장치에서 입사표면선량률 평가)

  • Kang, Byung-Sam;Chang, Kwang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.

Surface Treatment of Eggshells with Low-Energy Electron Beam

  • Kataoka, Noriaki;Kawahara, Daigo;Sekiguchi, Masayuki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Background: Salmonella enteritidis (SE) was the main cause of the pandemic of foodborne salmonellosis. The surface of eggs' shells can be contaminated with this bacterium; however, washing them with sodium hypochlorite solution not only reduces their flavor but also heavily impacts the environment. An alternative to this is surface sterilization using low-energy electron beam. It is known that irradiation with 1 kGy resulted in a significant 3.9 log reduction (reduction factor of 10,000) in detectable SE on the shell. FAO/IAEA/WHO indicates irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard. On the other hand, the Food and Drug Administration has deemed a dose of up to 3 kGy is allowable for eggs. However, the maximum dose permitted to be absorbed by an edible part (i.e., internal dose) is 0.1 Gy in Japan and 0.5 Gy in European Union. Materials and Methods: The electron beam (EB) depth dose distribution in the eggshell was calculated by the Monte Carlo method. The internal dose was also estimated by Monte Carlo simulation and experimentation. Results and Discussion: The EB depth dose distribution for the eggshells indicated that acceleration voltages between 80 and 200 kV were optimal for eggshell sterilization. It was also found that acceleration voltages between 80 and 150 kV were suitable for reducing the internal dose to ≤ 0.10 Gy. Conclusion: The optimum irradiative conditions for sterilizing only eggshells with an EB were between 80 and 150 kV.

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Comparison on the Dosimetry of TLD and OSLD Used in Nuclear Medicine (광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교)

  • Lee, Wang-Hui;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.329-334
    • /
    • 2012
  • For the dosimetry of the radiation workers, film badge, Thermo Luminescent Dosimeter (TLD), and glass dosimeter are being used and recently, there is a growing trend of using Optically Stimulated Luminescence Dosimeter (OSLD) in the world. However, OSLD is only being applied some of the field in Korea and there has been almost no study made related to OSLD. Thus, the accumulated radiation dose of TLD and OSLD that have been most frequently used in the field was compared in the radiation workers of nuclear medicine and their working areasfor 3 months. As a result, the average surface dose showed 0.85 mSv difference with 1.27 mSv for TLD and 2.12 mSv for OSLD while having 0.73 mSv difference for the average depth dose with 1.33 mSv for TLD and 2.06 mSv for OSLD. The surface dose and depth dose of OSLD showed statistically significant result with higher measurement (p<0.05).

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Effects of Self-Made Bismuth Shield Installation on Entrance surface Dose Reduction during Endovascular Treatment of Cerebral Aneurysms (뇌동맥류 코일 색전술시 자체 제작한 Bismuth 차폐체 설치의 피부선량 감소 효과)

  • Kim, Jae-Seok;Kim, Young-Kil;Choi, Jae-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.175-183
    • /
    • 2019
  • Cerebral nervous system intervention has been reported frequently due to radiation exposure such as blistering of the skin, hair loss, and erythema due to prolonged procedures. By applying ergonomically manufactured Bismuth (atomic number 83; Bi) shield to endovascular treatment of cerebral aneurysms, we aimed to minimize radiation exposure of scalp and lens from medical radiation exposure. The measurement site was the posterior part of the head, bilateral temporal part, bilateral quadriceps part, nose part, and the measuring part was attached to the optically stimulated Luminescence dosimeter (OSLD) Before and after the use, the entrance surface dose was compared and analyzed. The average entrance surface dose of group A (unshield) was 92.44 mGy, and group B was measured at 67.55 mGy. The average decrease in Group B was 26.92% compared to Group A. The entrance surface dose mean of the occipital region was measured at 146.08 mGy B group at 103.23 mGy and decreased by an average of 29.32% in group B compared to group A. The average entrance surface dose of the bilateral temporal part was measured in group A at 101.90 mGy group B at 72.69 mGy and decreased by an average of 28.67% in group B compared to group A. The average entrance surface dose for bilateral quadriceps part was measured at 27.51 mGy group B at 21.39 mGy and averaged 22.26% less in group B than group A. It is believed that the use of bismuth shields will be an alternative to reducing radiation disturbance due to temporary hair loss and other stochastic effects that may occur after the endovascular treatment of cerebral aneurysms procedure.

Assessment of radiation exposure from cesium-137 contaminated roads for epidemiological studies in Seoul, Korea

  • Lee, Yun-Keun;Ju, Young-Su;Lee, Won Jin;Hwang, Seung Sik;Yim, Sang-Hyuk;Yoo, Sang-Chul;Lee, Jieon;Choi, Kyung-Hwa;Burm, Eunae;Ha, Mina
    • Environmental Analysis Health and Toxicology
    • /
    • v.30
    • /
    • pp.5.1-5.8
    • /
    • 2015
  • Objectives We aimed to assess the radiation exposure for epidemiologic investigation in residents exposed to radiation from roads that were accidentally found to be contaminated with radioactive cesium-137 ($^{137}Cs$) in Seoul. Methods Using information regarding the frequency and duration of passing via the $^{137}Cs$ contaminated roads or residing/working near the roads from the questionnaires that were obtained from 8875 residents and the measured radiation doses reported by the Nuclear Safety and Security Commission, we calculated the total cumulative dose of radiation exposure for each person. Results Sixty-three percent of the residents who responded to the questionnaire were considered as ever-exposed and 1% of them had a total cumulative dose of more than 10 mSv. The mean (minimum, maximum) duration of radiation exposure was 4.75 years (0.08, 11.98) and the geometric mean (minimum, maximum) of the total cumulative dose was 0.049 mSv (<0.001, 35.35) in the exposed. Conclusions An individual exposure assessment was performed for an epidemiological study to estimate the health risk among residents living in the vicinity of $^{137}Cs$ contaminated roads. The average exposure dose in the exposed people was less than 5% of the current guideline.