• 제목/요약/키워드: average filter

검색결과 902건 처리시간 0.03초

순서 통계형-적응 가중평균 혼성필터를 이용한 잡음화된 영상열의 향상 (Enhancement of noisy image sequence using order statistic-adaptive weighted average hybrid filters)

  • 박순영
    • 한국통신학회논문지
    • /
    • 제22권1호
    • /
    • pp.193-204
    • /
    • 1997
  • In this research we propose the design of the Order Statistic-Adaptive Weighted Average Hybrid(OS-AWAH) filter which can suppress noise from the corrupted image sequence effectively while preserving the image structure. The proposed filter combines the desirable properties of the order static based spatial filter which can preserve the image structure while reducing noise and the adaptive weighted average based temporal filter which can adapt the filtering weights according to the amount of motion without motion estimation. Performance characteristics of the OS-AWAH filter in noisy sequences containing moving step edges are investigated throuth computer simulations and compared with the median based filters such as 3-D WM(weighted median) filter, MMF (multistage median filter), ADCWM(adaptive directional center weighted median) filter. The visual evaluations are also carried out by applyin gthe filters to the real images. The statistical analysis and experimental reslts show that the OS-AWAH filter is effective in preserving image structures while suppressing noise effectively without motion compensation preprocessing.

  • PDF

디지털 가변저항과 지수가중 이동평균필터를 통한 요골동맥에서의 PPG 파형과 맥박 측정에 관한 연구 (A Study of PPG Wave and Pulse Measurement on Radial Artery Using Digital Potentiometer and Exponentially Weighted Moving Average Filter)

  • 정인복;김경호
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.962-967
    • /
    • 2014
  • In this paper, through a digital potentiometer and exponentially weighted moving average filter, pulse and PPG waveform measurable device was fabricated in radial artery. If this device is not proper about signal size in analog part, MCU can judge easily by adjusted amplification through digital potentiometer, using exponentially weighted moving average filter is able to filter out more clear value of ADC. I presumed pulse rate as value of measuring time between point of maximum contraction from sensing signal in radial artery of wrist. Therefore, this means can measure stable pulse rate and PPG waveform, finger as well as radial artery, whether signal size of each person is different finger as well as radial artery.

혼재된 잡음 영상내 필터 개선에 의한 잡음제거 (Noise Reduction by Filter Improvement in Mixed Noise Image)

  • 임재원;김응규
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.231-241
    • /
    • 2013
  • 본 연구에서는 임펄스 잡음과 가우시안 잡음 및 혼재된 영상의 잡음을 효과적으로 제거하기 위한 평균 근사 값 필터를 제안한다. 먼저, 잡음을 검출하기 위한 단계로서 적용 마스크 내의 최소 최대값을 제거한 평균을 구한 후, 화소 값과 평균값의 차이가 임계 값 이상인지 알아본다. 화소 값이 임계 값 이상이면 잡음으로 처리하고, 임계 값 이하이면 비 잡음으로 처리한다. 다음으로, 잡음을 제거하기 위한 단계로서 잡음이 포함된 화소의 최소 최대값을 제외한 평균값과 마스크 내 가장 근사한 값을 화소 값으로 출력한다. 이러한 평균 근사 값 필터를 혼재된 잡음 영상에 적용한 결과, 중앙값 필터와 평균값 필터만을 각각 적용했을 때에 비해 0.4[dB] 이상 효과적으로 잡음을 제거할 수 있었다.

Decentralized Moving Average Filtering with Uncertainties

  • Song, Il Young
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.418-422
    • /
    • 2016
  • A filtering algorithm based on the decentralized moving average Kalman filter with uncertainties is proposed in this paper. The proposed filtering algorithm presented combines the Kalman filter with the moving average strategy. A decentralized fusion algorithm with the weighted sum structure is applied to the local moving average Kalman filters (LMAKFs) of different window lengths. The proposed algorithm has a parallel structure and allows parallel processing of observations. Hence, it is more reliable than the centralized algorithm when some sensors become faulty. Moreover, the choice of the moving average strategy makes the proposed algorithm robust against linear discrete-time dynamic model uncertainties. The derivation of the error cross-covariances between the LMAKFs is the key idea of studied. The application of the proposed decentralized fusion filter to dynamic systems within a multisensor environment demonstrates its high accuracy and computational efficiency.

AWGN 제거를 위한 표준편차 기반의 거리가중치 필터 (Distance Weighted Filter based on Standard Deviation Distribution for AWGN Removal)

  • 박화정;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.118-120
    • /
    • 2021
  • 현대 사회는 IoT 기술의 발달에 따라 CCTV, 탐사로봇 등 폭넓은 분야에서 다양한 디지털 장비들이 보급되고 있다. 이에 데이터처리의 중요성이 커지고 있으며, 영상 분야에서도 데이터를 수신하는 과정에서 발생하는 잡음을 제거하기 위한 다양한 연구들이 진행되고 있다. 대표적인 잡음으로 AWGN(additive white Gaussian noise)이 있으며, 잡음을 제거하기 위한 기존의 필터로는 평균필터(AF : average filter), 알파 트림드 평균필터(A-TAF : alpha trimmed average filter), 메디안필터(MF : median filter) 등이 있다. 하지만 기존의 필터들은 고주파영역에서의 잡음 제거 특성이 다소 미흡한 성능을 보이는 단점이 있다. 따라서 본 논문에서는 고주파영역에 존재하는 AWGN을 효과적으로 제거하기 위해 표준편차를 기반한 거리에 따른 가중치필터를 제안한다.

  • PDF

복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

해상물체탐지시스템 거리오차 보정에 관한 연구 (A Study on the Distance Error Correction of Maritime Object Detection System)

  • 강병선;정창현
    • 해양환경안전학회지
    • /
    • 제29권2호
    • /
    • pp.139-146
    • /
    • 2023
  • 양식장 부표 등과 같은 해상의 소형 장애물을 탐지하고 거리와 방위를 시각화시켜 주는 해상물체탐지시스템은 선체운동으로 인한 오차를 보정하기 위해 3축 짐벌이 장착되어 있지만, 파도 등에 의한 카메라와 해상물체의 상하운동으로 발생하는 거리오차를 보정하지 못하는 한계가 있다. 이에 본 연구에서는 외부환경에 따른 수면의 움직임으로 발생하는 해상물체탐지시스템의 거리오차를 분석하고, 이를 평균필터와 이동평균필터로 보정하고자 한다. 가우시안 표준정규분포를 따르는 난수를 이미지 좌표에 가감하여 불규칙파에 의한 부표의 상승 또는 하강을 재현하였다. 이미지 좌표의 변화에 따른 계산거리, 평균필터와 이동평균필터를 통한 예측거리 그리고 레이저 거리측정기에 의한 실측거리를 비교하였다. phase 1,2에서 불규칙파에 의한 이미지 좌표의 변화로 오차율이 최대 98.5%로 증가하였지만, 이동평균필터를 사용함으로써 오차율은 16.3%로 감소하였다. 오차보정 능력은 평균필터가 더 좋았지만 거리변화에 반응하지 못하는 한계가 있었다. 따라서 해상물체탐지시스템 거리오차 보정을 위해 이동평균필터를 사용함으로써 실시간 거리변화에 반응하고 오차율을 크게 개선할 수 있을 것으로 판단된다.

프레임 단위의 AELMS를 이용한 잡음 제거 알고리즘 (Noise Reduction Algorithm using Average Estimator Least Mean Square Filter of Frame Basis)

  • 안찬식;최기호
    • 디지털융복합연구
    • /
    • 제11권7호
    • /
    • pp.135-140
    • /
    • 2013
  • 잡음 추정과 검출 알고리즘에서는 LMS Filter를 이용하여 변화하는 잡음 환경에 빠르게 적응할 수 있도록 한다. 하지만 LMS Filter는 잡음 추정을 위한 일정 시간 동안 적응 시간이 필요하며 신호의 변화가 일어날 경우 더 많은 적응 시간이 소요되는 단점을 가지고 있다. 따라서 이를 보완하기 위하여 프레임 단위의 AELMS Filter를 이용한 잡음 제거 방법을 제안한다. 본 논문은 잡음 환경에서 입력되는 신호를 프레임 단위로 분할하고 평균과 분산을 이용한 예측 LMS Filter를 구성하여 잡음을 제거하므로 잡음 환경이 변화하더라도 빠른 적응 시간으로 잡음을 제거한다. 또한 환경 잡음과 음성 신호가 혼합되어 입력될 때 잡음을 제거하여 음성의 고유 특성을 유지하고 음성 정보 손상을 줄이기 위한 방법이다. 프레임 단위의 AELMS Filter를 이용한 잡음 제거 방법으로 잡음 제거 성능을 평가하였다. 실험 결과 변화하는 환경 잡음을 제거하여 얻은 감쇠도가 평균 6.8dB 향상되었다.

Information Authentication of Three-Dimensional Photon Counting Double Random Phase Encryption Using Nonlinear Maximum Average Correlation Height Filter

  • Jang, Jae-Young;Inoue, Kotaro;Lee, Min-Chul;Cho, Myungjin
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.228-233
    • /
    • 2016
  • In this paper, we propose a nonlinear maximum average correlation height (MACH) filter for information authentication of photon counting double random phase encryption (DRPE). To enhance the security of DRPE, photon counting imaging can be applied because of its sparseness. However, under severely photon-starved conditions, information authentication of DRPE may not be implemented successfully. To visualize the photon counting DRPE, a three-dimensional imaging technique such as integral imaging can be used. In addition, a nonlinear MACH filter can be utilized for helping the information authentication. Therefore, in this paper, we use integral imaging and nonlinear MACH filter to implement the information authentication of photon counting DRPE. To verify our method, we implement optical experiments and computer simulation.

Target Detection for Marine Radars Using a Data Matrix Bank Filter

  • Jang, Moon Kwang;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제13권3호
    • /
    • pp.151-157
    • /
    • 2013
  • Marine radars are affected by sea and rain clutters, which can make target discrimination difficult. The clutter standard deviation and improvement factor are applied using multiple parameters-moving speed of radar, antenna speed, angle, etc. When a radar signal is processed, a Data Matrix Bank (DMB) filter can be applied to remove sea clutters. This filter allows detection of a target, and since it is not affected by changes in adjacent clutters resulting from a multi- target signal, sea state clutters can be removed. In this paper, we study the level for clutter removal and the method for target detection. In addition, we design a signal processing algorithm for marine radars, analyze the performance of the DMB filter algorithm, and provide a DMB filter algorithm design. We also perform a DMB filter algorithm analysis and simulation, and then apply this to the DMB filter and cell-average constant false alarm rate design to show comparative results.