• Title/Summary/Keyword: available power

Search Result 1,805, Processing Time 0.028 seconds

A parametric bootstrap test for comparing differentially private histograms (모수적 부트스트랩을 이용한 차등정보보호 히스토그램의 동질성 검정)

  • Son, Juhee;Park, Min-Jeong;Jung, Sungkyu
    • The Korean Journal of Applied Statistics
    • /
    • v.35 no.1
    • /
    • pp.1-17
    • /
    • 2022
  • We propose a test of consistency for two differentially private histograms using parametric bootstrap. The test can be applied when the original raw histograms are not available but only the differentially private histograms and the privacy level α are available. We also extend the test for the case where the privacy levels are different for different histograms. The resident population data of Korea and U.S in year 2020 are used to demonstrate the efficacy of the proposed test procedure. The proposed test controls the type I error rate at the nominal level and has a high power, while a conventional test procedure fails. While the differential privacy framework formally controls the risk of privacy leakage, the utility of such framework is questionable. This work also suggests that the power of a carefully designed test may be a viable measure of utility.

Artificial Intelligence Inspired Intelligent Trust Based Routing Algorithm for IoT

  • Kajol Rana;Ajay Vikram Singh;P. Vijaya
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.11
    • /
    • pp.149-161
    • /
    • 2023
  • Internet of Things (IoT) is a relatively new concept that has gained immense popularity in a short period of time due to its wide applicability in making human life more convenient and automated. As an illustration: the development of smart homes, smart cities, etc. However, it is also accompanied by a substantial number of risks and flaws. IoT makes use of low-powered devices, so secure, less time-consuming and energy-intensive transmission (routing) of messages due to the limited availability of energy is one of the many and most significant concerns for IoT developers. The following paper presents a trust-based routing scenario for the Internet of Things (IoT) that exploits the past transmission record from the cupcarbon simulator's log files. Artificial Neural Network is used to quantify knowledge of trust, calculate the value of trust, and share this information with other network devices. As a human behavioural pattern, trust provides a superior method for making routing decisions. If there is a tie in the trust values and no other path is available, the remaining battery power is used to break the tie and make a forwarding decision; this is also seen as a more efficient use of the available resources. The proposed algorithm is observed to have superior energy consumption and routing decisions compared to conventional routing algorithms, and it improves the communication pattern.

Design of a Vibration Energy Harvesting Circuit With MPPT Control (MPPT 제어 기능을 갖는 진동에너지 하베스팅 회로 설계)

  • Park, Joon-Ho;Yoon, Eun-Jung;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2457-2464
    • /
    • 2011
  • In this paper, a vibration energy harvesting circuit using a piezoelectric device is designed. MPPT(Maximum Power Point Tracking) control function is implemented using the electric power-voltage characteristic of a piezoelectric device to deliver the maximum power to load. The designed MPPT control circuit traces the maximum power point by periodically sampling the open circuit voltage of a full-wave rectifier circuit connected to the piezoelectric device output and delivers the maximum available power to load. The proposed vibration energy harvesting circuit is designed with $0.18{\mu}m$ CMOS process. Simulation results show that the maximum power efficiency of the designed circuit is 91%, and the chip area except pads is $700{\mu}m{\times}730{\mu}m$.

Modeling of the T.C.M.S. using Power Line Carrier in Railway

  • Song, Y.S.;Lee, S.G.;Shin, S.K.;Han, S.H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2147-2150
    • /
    • 2003
  • Recently, many technologies of the P.L.C (Power Line Carrier) are introduced for an efficient communication. P.L.C communication sends information in the carrier signals by conduction over the power wire. An arc detector is proposed in this paper for the effective transmission. The Power Line Carrier has an advantage in low cost because it uses existent power line. It can be easily applied anywhere that a power line socket is available. But the P.L.C. is very noisy, because many electronic devices in generate electronic noise in modulated signals. This problem should be considered carefully in the design of the arc detector system using P.L.C in railway. The proposed system can be applied for monitoring the arc detector system and the arc locator system in railway. Hence the system will be able to exchange the arc information to be T.C.M.S. (Train Control Management System), bogies and even between a station and trains in railway and use to suspicion fire in train.

  • PDF

Comparison of Generation Amount and Operating Time for Fixed-concentrated Type and Single Axis Trace Type of Photovoltaic (고정식 및 단축식 태양광 발전의 발전량과 운전시간의 비교)

  • Song, Hwan-Kee;Lee, Kyung-Sup;Choi, Yong-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.11
    • /
    • pp.743-747
    • /
    • 2015
  • In this paper, the power generation efficiency of the 4 [kW] fixed-concentrated type photovoltaic power generation system and that of the 4 [kW] single axis trace type photovoltaic power generation system were compared. For that purpose, the two types of photovoltaic power generation systems have been in operation for 1 year on an experimental basis. The amounts of power generated by the two types during the months of January through December and the characteristics of their operating times during the same period have been compared and analyzed. For the study, the type with higher efficiency was selected and the following conclusions have been reached. It was shown that the amount of power generated and the average operation times during the spring months of March through May are higher that those of the summer months of June through August when more sunlight is available. The reason for this phenomenon is thought to be that as the temperatures of the solar panel surface and the surrounding environment go up, the electric current decreases.

An Analysis on Possibility and Effect of Market Power under the 3rd Long Term Power Plan (제3차 전력수급기본계획에 따른 시장지배력 행사가능성 및 영향분석)

  • Lee, Jae-Gul;Park, Min-Hyuk;Ahn, Nam-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1017-1022
    • /
    • 2007
  • In this paper, we try to analyze the likelihood of exercising the power of market dominance by certain generators in future power industry of Korea. Firstly, we estimated installed generation capacity and sales volume of electricity in Korea, based on 'The 3rd Long Term Power Plan' which was announced in December 2006. Secondly, we calculated HHI, an index showing the degree of concentration of an industry, and RSI, an index showing how adequate the supply of goods or services of an industry is, using Fast-Forward. Thirdly, assuming a major generator employs the strategy of withholding a part of its available capacity at a peak time, we simulated hypothetical movement of SMP over a certain period of time, which is compared with that obtained without assuming such strategy to generate Lerner Index. an index showing the degree of market power of a monopoly. Regulators, home and abroad, have not given much interest in analyzing the effect of market dominance that is likely to be exercised by certain players in the future. That said, this paper provides insight into developing methodologies of analyzing and mitigating such effect by proposing the above indices to gauge it. In addition, this paper also shows the potential impact of employing capacity withholding strategy on the financial account of a dominant generator.

Development of Integrated Start-up and Excitation System for Gas Turbine Synchronous Generator (가스터빈 동기기 통합형 기동 및 여자시스템 개발)

  • Ryu, Hoseon;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.183-188
    • /
    • 2014
  • Power conversion systems used in large gas turbine power plant can be divided into two main part. Because of the initial start-up characteristic of the gas turbine combustor, the gas turbine must be accelerated by starting device(LCI : Load Commutated Inverter) up to 10%~20% of rated speed to ignite it. In addition, the ECS(Excitation Control system) is used to control the rotor field current and reactive power in grid-connected synchronous generator. These two large power conversion systems are located in the same space(container) because of coordination control. Recently, many manufactures develop high speed controller based on function block available in the LCI and ECS with the newest power semiconductor. We also developed high speed controller based on function block to be using these two system and it meets the international standard IEC61131 as using real-time OS(VxWorks) and ISaGRAF. In order to install easily these systems at power plant, main controller, special module and IO module are used with high speed communication line other than electric wire line. Before initial product is installed on the site, prototype is produced and tests are conducted for it. The performance results of Integrated controller and application program(SFC, ECS) were described in this paper. The test results will be considered as the important resources for the application in future.

Power Quality Analysis of Wind-Diesel Hybrid Generation System Installation Area (복합발전 풍력-디젤 하이브리드 시스템 설치 지역의 전력품질 분석)

  • An, Hae-Joon;Kim, Hyun-Goo;Kim, Seok-Woo;Ko, Seok-Whan;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.539-541
    • /
    • 2009
  • A severely cold weather condition of King Sejong Station, Antarctica becomes a very severe condition for an installation/operation of wind generation system. When the existing wind generation system works, it may cause a damage and destruction of wind generation system and can bring about big problems in terms of the power quality. Accordingly, it is essential to obtain technologies for the installation and operation of small wind generation system for the polar region's wind generation, and to assess and demonstrate the performance in the severely-cold environment and the polar wind generation system's development, supplementation, alteration. Also, as the available power of King Sejong Station, Antarctica, the diesel generator has been mainly used, and the wind generator has been used in the hybrid form. Wind generation and diesel generation has the different load following control each other. In the wind generation, the generated power very rapidly changes according to the change of the velocity of the wind. On the other hand, the diesel generation shows very gentle change in the velocity of output. Therefore, the study is intended to analyze the 10kw small wind generator-diesel generator's power quality of King Sejong Station, Antarctica, which is the hybrid system installation area.

  • PDF

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF

Design and Fabrication of S-band Ultra High Power Transistorized Amplifier (마이크로파대 고출력 트란지스터 증폭기의 설계와 시작)

  • 심재철;김종련
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.5
    • /
    • pp.7-14
    • /
    • 1977
  • Conventionally, a TIVT has been used for high power amplification in the microwave frequency range. However, an ultra-high-power amplifier in the 2GHz range has successfully been designed and fabricated employing high power transistors developed recently and available commercially. In the design of the amplifier, a balanced-pair configuration is adopted in order to obtain very high microwave power, and a good impedance matching is achieved by making use of microstripline techniques. For the RF power divider as well as combiner, an approach of stripline directional coupler isadopted because of its easiness in fabrication. The coupler so designed and fabricated indicates a satisfactory performance as a quadrature hybrie coupler. Measurements on the amplifier developed for an immediate commercial application also exhibit excellent overall performance characteristics RF power output, 14 watts, gain 14dB, frequency bandwidth, 160MHz, effciency 40%.

  • PDF