• Title/Summary/Keyword: auxiliary switching circuit

Search Result 243, Processing Time 0.029 seconds

A Simple Resonant DC Link Snubber-Assisted Bi-directional Three-phase PWM Converter for Battery Energy Storage Systems

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.133-139
    • /
    • 2002
  • In this paper, a prototype of an active auxiliary quasi-resonant DC link (QRDCL) snubber assisted voltage source bidirectional power converter (AC to DC and DC to AC) operating at zero voltage soft-switching (BVS) PWM nlode is presented for a Battery Energy Storage System (BESS). The operating principle of this QRDCL circuit and multifunctional control-based converter system, including PWM inverter mode in which energy flows from the battery bank to the three-phase utility-grid in addition to an active PWM converter mode in which energy flows from the utility-grid to the battery banks are described respectively by the control implementation on the basis of d-q coordinate plane transformation. The multifunctional operation characteristics of this three-phase ZVS PWM bi-directional converter with QRDCL is demonstrated fer a BESS under the power conditioning and processing schemes of energy supply mode and energy storage mode, and compared with a conventional three-phase hard switching PWM bi-directional converter for a BESS. The effectiveness of the three-phase ZVS PWM hi-directional converter with QRDCL is proven via the simulation analysis.

A New Current Controlled Inverter with ZVT Switching

  • Lee S. R.;Jeon C. H.;Ko S. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.309-313
    • /
    • 2001
  • A single-phase bi-directional inverter with a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is proposed. It is shown that the polarized ramptime current control algorithm, a method that belongs to the family of ZACE(Zero Average Current Error) methods, is a suitable technique to integrate with a typical single-phase ZVT inverter. The proposed current control algorithm is analyzed to design the circuit with auxiliary switch which can operate with ZVT for the main power switch. The simulation results would be shown to verify the proposed current algorithm to turn the main power switch on with ZVT and to operate the inverter bi-directionally

  • PDF

A study of AC-DC PFC ZVS Interleaved Boost Converter (AC-DC PFC ZVS 인터리브 승압형 컨버터에 관한 연구)

  • Lee, Sung-Ho;Kim, Yong;Seo, Sang-Hwa;Kwon, Soon-Do;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1224-1225
    • /
    • 2011
  • This paper proposes a novel soft-switching interleaved boost converter composed of two shunted elementary PFC boost conversion units and an auxiliary inductor. This converter is able to turn on both the active power switches at zero voltage to reduce their switching losses and evidently raise the conversion efficiency and power factor. Since the two parallel-operated elementary boost units are identical, operation analysis and design for the converter module becomes quite simple. A laboratory test circuit is built, and the circuit operation shows satisfactory agreement with the theoretical analysis. The performance of the proposed PFC rectifier was evaluated on an experimental 300[W] PFC prototype.

  • PDF

A Simple ZVT PWM Single-Phase Rectifier with Reduced Conduction Loss and Unity Power Factor

  • Kim, In-Dong;Choi, Seong-Hun;Nho, Eui-Cheol;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.55-63
    • /
    • 2007
  • This paper proposes a simple unity power factor zero-voltage-transition (ZVT) pulse-width-modulated (PWM) single-phase rectifier, which features reduced switching and conduction losses. The switching loss reduction is achieved by a simple auxiliary commutation circuit, and the conduction loss reduction is achieved by employing a single-stage converter, rather than a typical double-stage converter comprising of a front-end rectifier and a boost rectifier. Furthermore, thanks to good features such as a simple PWM control at constant frequency, low switch stress, low Var rating of commutation circuits, and simple power circuit structure, it is suitable for high power applications. The principles of operation are explained in detail, and a major characteristics analysis and the experimental results of the new converter are also included in this paper.

Development of a Topology for the Power Supply with Reduced Conduction Loss and Swithing Stress (도전손실과 스위칭 스트레스 저감한 전원장치 토폴로지의 개발)

  • 라병훈;권순걸;이현우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.245-248
    • /
    • 2001
  • This paper is indicating the problems, which are the conduction loss on the high frequency transformer, the protection of rectification diode as the snubber loss and the stress of switching main devices, as be made high current and high speed in the phase-shift switching full-bridge DC-DC converter is used the power supply’s main circuit of high capacity. To improve those problems, in this paper, it is proposed that is the resonant circuit auxiliary can be reduced conduction losses and stabilized output control. And, it is constructed prototype of the power supply as the result of computer simulations.

  • PDF

A Study On The High Frequency Switching Of Zero Voltage Switching Converter (영전압 스위칭 컨버터의 고속 스위칭에 관한 연구)

  • Kim, In-Soo;Kim, Eui-Chan;Lee, Byung-Ha;Sung, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.537-539
    • /
    • 1996
  • In this paper, a design method of the phase shift ZVS-PWM converter is proposed to minimize the volume and increase the efficiency. The trade-offs of switching frequency, efficiency vs volume and ZVS range vs efficiency is also presented. The simulation of the designed converter is performed using the P-SPICE in which a phase-shift controller is proposed. For minimization of the converter volume, switching frequency is selected 100kHz, a simple drive circuit and single auxiliary supply are applied. In consideration of efficiency and load condition, ZVS range is decided from 50% to full load. A 28V, 1Kwatt prototype converter, of which the switch is MOSFET is made, verified the performance.

  • PDF

Zero-Voltage Switching Dual Inductor-fed DC-DC Converter Integrated with Parallel Boost Converter

  • Seong, Hyun-Wook;Park, Ki-Bum;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.523-525
    • /
    • 2008
  • Novel zero-voltage switching(ZVS) dual inductor-fed DC-DC converter integrating a conventional dual inductor-fed boost converter(DIFBC) and a parallel bidirectional boost converter has been proposed. Most of current-fed type boost topologies including dual inductor schemes have crucial defects such as a high voltage spike on the main switch when it comes to turning off, an unattainable soft start-up due to the limited range of duty ratio, above 50%, and considerable switching losses due to the hard switching. By adding two auxiliary switches and an output capacitor on the conventional DIFBC, the proposed circuit can solve mentioned problems and improve the efficiency with simple methods. The operational principle and theoretical analysis of the proposed converter have been included. Experimental results based on a 42V input, 400V/1A output and 50kHz prototype are shown to verify the proposed scheme.

  • PDF

A Soft Switching Bidirectional DC-DC Converter Using ZCT method (ZCT 방식을 이용한 양방향 소프트 스위칭 DC-DC 컨버터)

  • Lee, Il-Ho;Park, Kun-Wook;Jung, Doo-Yong;Kim, Jae-Hyung;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.479-480
    • /
    • 2010
  • In this paper, the bi-directional soft switching DC-DC converter using ZCT(Zero Current Transition) method is proposed for using battery application system. This topology is composed of soft switching bi-directional buck/boost converter having the ZCT auxiliary circuit with two switches, two resonant capacitors, one resonant inductor. Therefore, the proposed topology can reduce switching loss. To verify the validity of the proposed topology, theoretical analysis and simulation results are presented.

  • PDF

The study of New multi-level inverter with simple structure (간단한 구조를 갖는 새로운 방식의 멀티 레벨 인버터에 관한 연구)

  • Lee, Byung-Jin;Jung, Byung-Chang;Ru, Chul-Ro;Lee, Seong-Ryong;Han, Woo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1963-1965
    • /
    • 1998
  • In this paper, a new simplified configuration for a multi-level PWM inverter is proposed. The proposed inverter consists of an auxiliary circuit with one switching device, and 3 phase full-bridge inverter. The proposed inverter, in spite of reduction of the switching devices, offers characteristics similar to the NPC(Neutral - point - clamped)- PWM inverter. Also, since the reduction of the switching devices, the control strategy is simplified. And switching loss is reduced. In addition to, it is possible that reliable DC level voltage than former multi-level inverter. And load power application is same to conventional NPC-PWM inverter. The performance of the system is verified by simulation. In this paper, show the simulation result of the single phase full bridge inverter application.

  • PDF

Study on intense pulse lighting with high efficiency (고효율의 Intese Pulse Light에 특성연구)

  • Kim, Whi Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.333-336
    • /
    • 2009
  • the equipment increase switching frequency in order to achieve small size, a low noise, and light weight. however, the power switches have high power losses and switching stresses as the switching frequency is increased. In order to solve like this problem point from the present paper it proposed Intese Pulse Light of the half bridge methods which apply the start current circuit which applies the auxiliary equipment. Simulation and experimental result it leads and it brings is more qualitative there is 20% improvement and it confirmed that a possibility of measuring to the patient.

  • PDF