• Title/Summary/Keyword: auxiliary

Search Result 2,753, Processing Time 0.045 seconds

Reciprocal Sustain and Auxiliary Pulse Waveforms Applied to an AC PDP with an Auxiliary Electrode

  • Choi, Kyung-Cheol;Lee, Sung-Min;Choi, Chung-Sock;Jang, Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1543-1546
    • /
    • 2008
  • Modified pulse waveforms were applied to an AC plasma display panel with an auxiliary electrode in order to improve the operation voltage margin. Reciprocal sustain pulse waveforms and modified auxiliary pulse waveforms were applied to the sustain and auxiliary electrode, respectively. During the sustain period, the influence of the address electrode on the luminous efficacy of long-coplanar gap discharges was mitigated by application of reciprocal sustain pulse waveforms. Modified auxiliary pulse waveforms maintained the high efficacy obtained from the AC PDP with an auxiliary electrode. The proposed reciprocal sustain and modified auxiliary pulses waveforms can induce stable discharges in long-coplanar gap discharges and can control wall charges with a wider auxiliary pulse voltage margin, thereby enhancing the luminous efficacy of the AC PDP with an auxiliary electrode.

  • PDF

Simultaneous operation of two group of Auxiliary Block for Korean High Speed Train (고속전철용 보조전력변환장치 1,2군 동시 기동)

  • Cho, Hyun-Wook;Kim, Yuen-Chung;Kim, Tae-Hwan;Jang, Kyung-Hyun;Choi, Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1626-1632
    • /
    • 2007
  • Power Car PC1 and PC2 of Korean high speed train have a auxiliary block which consists of two PWM converter respectively. If a auxiliary block happens a critical failure, the other supplies power to full load of train. In this case, a stability of auxiliary block reduces by a increasing load. For increasing a stability of auxiliary block and train system, a auxiliary block consists of two group four PWM converter which operates simultaneously. If a group of a auxiliary block happens a critical failure, the other supplies power to load of a auxiliary block. This paper describes a method for simultaneous movement of auxiliary block which consists of two group four PWM converter.

  • PDF

A Study for Characteristics of the Auxiliary Inverter in the 8200 Electric Locomotive (8200대 전기기관차 보조전원장치의 특성에 관한 연구)

  • Kim Jin-Yong;Lee Sang-Jun;Choi Jong-Mok;Kang Seung-Uk
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.237-244
    • /
    • 2005
  • The Auxiliary Inverter supply the power to Loads of Electric Locomotive. The Auxiliary Inverter have three characteristics. First, The Auxiliary Inverter is VVVF(variable voltage variable frequency) inverter. And, the output voltage is AC $0^{\sim}440V$. Second, The Auxiliary Inverter is controled all operations by CCU(Center Control Unit). Last, The Auxiliary Inverter have the SIBMON program. This program easily displays most of all status of auxiliary inverter.

  • PDF

Optimal Soft-Switching Scheme for Bidirectional DC-DC Converters with Auxiliary Circuit

  • Lee, Han Rim;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.681-693
    • /
    • 2018
  • This paper proposes a soft-switching bidirectional dc-dc converter (BDC) with an auxiliary circuit. The proposed BDC can achieve the zero-voltage switching (ZVS) using an auxiliary circuit in the buck and boost operations. The auxiliary circuit supplies optimal energy for the ZVS operation of the main switches. The auxiliary circuit consists of a resonant inductor, a back-to-back switch and two capacitors. A small-sized resonant inductor and an auxiliary switch with a low-rated voltage can be used in the auxiliary circuit. Zero-current switching (ZCS) turn-on and turn-off of the auxiliary switches are possible. The proposed soft-switching scheme has a look-up table for optimal switching of the auxiliary switches. The proposed strategy properly adjusts the turn-on time of the auxiliary switch according to the load current. The proposed BDC is verified by the results of PSIM simulations and experiments on a 3-kW ZVS BDC system.

A Study on Establish the Foundation of Electronic Payment System for the Auxiliary Costs of Foreign Trade - Focused on Logistic and Customs Clearance Areas - (수출입 부대비용의 EPS 기반구축에 관한 연구 - 물류.통관부문을 중심으로 -)

  • Shim, Chong-Seok;Yang, Jung-Ho
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.47
    • /
    • pp.185-212
    • /
    • 2010
  • This study aims to derive practical suggestions to apply application methods by auxiliary costs, especially application of logistics and customs clearance areas in order to establish EPS support system of auxiliary cost occurred from export/import. For the propose, this study has analyzed types and situation of auxiliary costs, application method by auxiliary costs, payment situation of logistics auxiliary costs and clearance auxiliary costs and suggested the relevant problems and their application methods. Especially, in case of logistics auxiliary costs through connection to the attached general documents required for negotiation by reflecting characteristics of B2B transactions. In addition, it has suggested that those services by the said system should be conveniently used commonly by the export companies and logistics companies through provision of various payment measures, support of foreign currency payment, etc. and security of reliability/system stability, etc. for the compatible payment with other systems as the prerequisite for the successful settlement of the auxiliary costs EPS. It is expected that satisfaction of the uTradeHub users such as export/import companies and logistics companies will be increased, user-oriented customized information services such as raw cost prediction service through calculation of auxiliary costs could be available in the future and efficiency of work processes related to auxiliary costs will be increased, by providing the EPS through various single window based payment measures through establishment of the export/import auxiliary costs payment system.

  • PDF

Efficacy of Auxiliary Traits in Estimation of Breeding Value of Sires for Milk Production

  • Sahana, G.;Gurnani, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.4
    • /
    • pp.511-514
    • /
    • 1999
  • Data pertaining to 1111 first lactation performance record of Karan Fries (Holstein-Friesian $\times$ Zebu) cows spread over a period of 21 years and sired by 72 bulls were used to examine the efficiency of sire indices for lactation milk production using auxiliary traits. First lactation length, first service period, first calving interval, first dry period and age at first calving were considered as auxiliary traits. The efficiency of this method was compared with simple daughter average index (D), contemporary comparison method (CC), least-square method (LSQ), simplified regressed least-squares method (SRLS) and best linear unbiased prediction (BLUP) for lactation milk production. The relative efficiency of sire evaluation methods using one auxiliary trait was lower (24.2-32.8%) in comparison to CC method, the most efficient method observed in this study. Use of two auxiliary traits at a time did not further improve the efficiency. The auxiliary sire indices discriminate better among bulls as the range of breeding values were higher in these methods in comparison to conventional sire evaluation methods. The rank correlation between breeding values estimated using auxiliary traits were high (0.77-0.78) with CC method. The rank correlation among auxiliary sire indices ranged from 0.98 to 0.99, indicating similar ranking of sire for breeding values of milk production in all the auxiliary sire indices.

A Characteristics of SPIM with Power Conversions of Auxiliary Winding (보조권선의 전력제어에 따른 단상유도전동기의 특성비교)

  • Park, Su-Kang;Seo, Kang-Sung;Baek, Hyung-Lae;Cho, Geum-Bae;Lim, Yang-Suo;Lee, Seong-Kil;Kim, Dong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1149-1151
    • /
    • 2002
  • In this paper, an auxiliary winding driving system of single-phase induction motors is described. Starting charateristics variations are obtained by controlling the auxiliary winding voltage magnitude and phase angle, while the motor's main winding is directly connected to the local utility. A variable auxiliary winding voltage phase angle is shown to yield significant torque control, providing starting and braking torque. The analysis includes the determination of the relationship between the auxiliary winding voltage phase angle and the phase angle difference between the main and auxiliary winding current. The paper proposed for adjusting an auxiliary winding voltage magnitude and phase angle. Experimental results of motor's starting characteristics with using the DC-AMP and PWM inverter for auxiliary winding power supply are shown. The drive is tested using a dynamometer to experimentally verify the results of the theory.

  • PDF

Trust Analysis of Ground Resistance Measurements by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정 신뢰성 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance. The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding a trust analysis of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a neutral line multiplex ground to earth, a wire net for auxiliary electrode. This information is confirmed bv compared with the measurement value.

Design of Auxiliary Circuit to Reduce Loss of ZVT Interleaved Flyback Converter (ZVT 인터리브드 Flyback 컨버터의 손실 저감을 위한 보조 회로 설계)

  • Jung, Won-sang;Lee, Soon-ryung;Lee, Jong-young;Park, Yun-ji;Won, Chung-yuen;Yi, Je-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.43-44
    • /
    • 2017
  • This paper presents design of auxiliary circuit to reduce loss of ZVT interleaved flyback converter. The ZVT interleaved converter using the conventional auxiliary circuit has a large conduction loss due to the constant circulating current in the auxiliary circuit. The auxiliary circuit proposed in this paper, which consists of the coupled inductor and DC-link capacitor, has linearly increasing or decreasing auxiliary current. Then, the conduction loss occurring in the auxiliary circuit is reduced. The validity of the proposed auxiliary circuit is verified with the prototype of 500W.

  • PDF

Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply (보조전원장치의 단락부하 차단기 개방을 위한 제어방법)

  • 황광철;조국춘;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF