• Title/Summary/Keyword: automatic test

Search Result 1,637, Processing Time 0.025 seconds

A LiDAR-based Visual Sensor System for Automatic Mooring of a Ship (선박 자동계류를 위한 LiDAR기반 시각센서 시스템 개발)

  • Kim, Jin-Man;Nam, Taek-Kun;Kim, Heon-Hui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1036-1043
    • /
    • 2022
  • This paper discusses about the development of a visual sensor that can be installed in an automatic mooring device to detect the berthing condition of a vessel. Despite controlling the ship's speed and confirming its location to prevent accidents while berthing a vessel, ship collision occurs at the pier every year, causing great economic and environmental damage. Therefore, it is important to develop a visual system that can quickly obtain the information on the speed and location of the vessel to ensure safety of the berthing vessel. In this study, a visual sensor was developed to observe a ship through an image while berthing, and to properly check the ship's status according to the surrounding environment. To obtain the adequacy of the visual sensor to be developed, the sensor characteristics were analyzed in terms of information provided from the existing sensors, that is, detection range, real-timeness, accuracy, and precision. Based on these analysis data, we developed a 3D visual module that can acquire information on objects in real time by conducting conceptual designs of LiDAR (Light Detection And Ranging) type 3D visual system, driving mechanism, and position and force controller for motion tilting system. Finally, performance evaluation of the control system and scan speed test were executed, and the effectiveness of the developed system was confirmed through experiments.

Exploring the Reliability of an Assessment based on Automatic Item Generation Using the Multivariate Generalizability Theory (다변량일반화가능도 이론을 적용한 자동문항생성 기반 평가에서의 신뢰도 탐색)

  • Jinmin Chung;Sungyeun Kim
    • Journal of Science Education
    • /
    • v.47 no.2
    • /
    • pp.211-224
    • /
    • 2023
  • The purpose of this study is to suggest how to investigate the reliability of the assessment, which consists of items generated by automatic item generation using empirical example data. To achieve this, we analyzed the illustrative assessment data by applying the multivariate generalizability theory, which can reflect the design of responding to different items for each student and multiple error sources in the assessment score. The result of the G-study showed that, in most designs, the student effect corresponding to the true score of the classical test theory was relatively large after residual effects. In addition, in the design where the content domain was fixed, the ranking of students did not change depending on the item types or items. Similarly, in the design where the item format was fixed, the difficulty showed little variation depending on the content domains. The result of the D-study indicated that the original assessment data achieved a sufficient level of reliability. It was also found that higher reliability than the original assessment data could be obtained by reducing the number of items in the content domains of operation, geometry, and probability and statistics, or by assigning higher weights to the domains of letters and formulas, and function. The efficient measurement conditions presented in this study are limited to the illustrative assessment data. However, the method applied in this study can be utilized to determine the reliability and to find efficient measurement conditions for the various assessment situations using automatic item generation based on measurement traits.

Ecotoxicity Test Using E. agilis Biomonitoring System (Euglena 운동성 측정장치를 이용한 생태독성평가)

  • Lee, Junga;Kim, Kyung Nam;Park, Da Kyung
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.2
    • /
    • pp.124-131
    • /
    • 2016
  • The toxic responses of flagellate Euglena agilis Carter to 8 heavy metals (Ag, Cd, Cr (VI), Cu, Hg, Ni, Pb, Zn) were measured using E. agilis system (E-Tox), an automated biomonitoring system. The E-Tox measures cell movement parameters, such as velocity, motility, and forms of the cells, as biological endpoints. $EC_{50}$ values from the E. agilis biomonitoring test were compared with the literature data from the tests with Daphnia magna, Vibrio fischeri and Euglena gracilis. Measurement of the E. agilis movement behavior and D. magna acute toxicity test were also conducted for the wastewater samples. E. agilis is less sensitive than D. magna but is comparable to or more sensitive than V. fischeri and E. gracilis for the heavy metals tested in this study. E. agilis shows prompt changes of these parameters for the toxic metal plating wastewater. Major advantages of the E-tox are automatic, easy to handle and fast ecotoxicity monitoring system compared to other biological test systems. These results imply that E. agilis biomonitoring test using E-Tox can be a putative ecotoxicity test as a good early warning tool for the monitoring of toxic wastewater.

Evaluation of water-Soluble Lubricant for Cold Forging and Optimization of Coating Process (냉간단조용 수용성 윤활제의 평가 및 윤활 처리 공정의 최적화)

  • Lim, W.J.;Lee, I.S.;Je, J.S.;Ko, D.C.;Kim, B.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.149-154
    • /
    • 2007
  • The zinc prosphate film treatments used to lubricating treatment of mostly cold forging processes. But there are several problems happened to lubricating treatment process such as happening harmful environment on person, complex lubrication processing occurring in energy and time consumption, eco-destructive and chemical by-product generation, the needs of waste disposal etc. As a result, a water-soluble lubricant was developed to replace the perfect or some of the zinc prosphate film in the world. In order to solve these problems, this study evaluated the performance of the typical water-soluble. In this study, for these requirement inquiry of two part. First, about possibility of replace zinc phosphate lubricant, quantitatively evaluation developed of water-soluble lubricant for cold forging vs zinc phosphate lubricant. Second, About optimization of coating Process use to equipment with practicable automatic coating Process. The performance evaluation of these lubricants was conducted using the double cup extrusion test and spike forging test. With the use of the commercial FE code DEFORM, friction factor calibration curves, i.e. cup height ratio vs. punch stroke and spike height vs. punch stroke, were established for different friction factor values. By matching the cup height ratio and the punch stroke and spike height vs. punch stroke from experiment to that obtained from FE simulations, the friction factor of the lubricants was determined. Survey of comparative analysis use to SEM that sprayed lubricant surface structure of grain shape and characteristic of lubricant performance based on grain shape and deformed lubricant surface expansion. As a result, developed lubricant were found to perform comparable to or better than zinc phosphate. And thought this result, innovatively cope with generated problem of existing lubrication process.

  • PDF

Development of Hole Expansion Test for Sheet Materials Using Pattern-Recognition Technique (형태 인식 기술을 이용한 판재의 홀 확장성 평가 시스템 개발)

  • Jang, Seung Hyun;Kim, Chan Il;Yang, Seung Han;Kim, Young Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.161-168
    • /
    • 2013
  • Nowadays, one of the most interested area of automobile industry is the production of vehicle which has collision safety and ability to produce less amount of $CO_2$. The achievement of such a dual performance is done by choosing the materials like dual phase steel, ferrite bainite steel, etc. These steels have been used in automotive chassis and body parts, and also used to be formed by hole flanging to meet the goal of strength and design requirement. The formability of sheet material was experimented by hole expansion test and the judgement relies on human eye and his experience. This manual judgement involves many errors and large deviation. This paper develops the automatic crack recognition system which finds a crack based on CCD image to complement the problem of the current method depending on human's sense.

Performance analysis for Ground Position Accuracy Test of MLAT (MLAT 지상 위치정확도 시험에 대한 성능 분석)

  • Koo, Bon-soo;Jang, Jae-won;Kim, Woo-riul;Kim, Tae-sik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.4
    • /
    • pp.325-331
    • /
    • 2017
  • As a GPS stability problem arises, MLAT system is spotlighted as an alternative technology of ADS-B. MLAT system has a high position accuracy as much as ADS-B. Also, MLAT receives the mode A,C,S, and 1090ES(ADS-B) signals from the mounted aircraft transponder. MLAT receives signals from several receiver units and calculates aircraft positions. MLAT has ADS-B level positioning accurarcy using GPS and can calculate the position information with objects independently. According to global environment changes, Local area multiltilateration(LAM) surveillance system is under development for moving vehicles and aircraft detection in airport. These are still under testing in Tae-an Airfield. In the paper, we analyzed the performance by comparing the calculated position data from MLAT to RTK. In order to confirm the position accuracy of MLAT and the deviation of position data between fixed target and moving target on the ground during the field test in Tae-an Airfield.

Estimation of Center Error in Active Magnetic Bearings through a Pull Test (당기기 시험을 통한 능동 자기베어링의 중심 오차 추정)

  • Nam, Sunggyu;Noh, Myounggyu;Park, Young-Woo;Lee, Nam Soo;Jeong, Jinhee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.121-127
    • /
    • 2017
  • From the perspective of commercializing rotating machines equipped with magnetic bearings, maintaining the error between the mechanical center and the magnetic center within an acceptable level is crucial. The existing method of measuring the center error is to adjust the position references that minimize the current imbalance present in levitation control outputs. However, this method can be applied only after all the components of the system are operational. In this paper, we present a new method of estimating the center error by using only the position sensors and a current source. A force model that relates the position of the rotor with the coil currents is set up. Using this model, the center error is estimated by minimizing the difference between the force angles and the contact angles measured in a pull test. The feasibility of the method is numerically and experimentally validated.

Development of a Portable Automatic Auditory Response Tester for Hearing Loss Screening (난청감별을 위한 휴대용 자동 청성반응 검사기의 개발)

  • Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.38-45
    • /
    • 2012
  • If an infant with congenital hearing loss is diagnosed in good time and get proper treatment as soon as possible, treatment effect could be maximized and the social costs could be considerably reduced. For these reasons, the medical equipment to screen hearing impairment objectively is needed. The ABR(auditory brainstem response) is typical diagnostic tools for this purpose but there are drawbacks in sense that it does not have frequency specificity and shows hearing information of usually high frequency band. The ASSR(auditory steady-state response) is excellent in frequency specificity, but the rate of wrong diagnosis is slightly high. In this study, we proposed the system which can measure both the ABR and the ASSR, and can show the objective and quantitative indices(Fsp and F-test). It was designed to allow various tests without hardware modification by minimizing hardware components and by increasing software roles. The objective assessment of the developed system was evaluated by experiments with 10 normal persons.

A Study on Online Detection Schemes of Earthquake Induced Shifts in Coordinate Time Series of GNSS Continuous Operation Reference Station by Kalman Filtering (칼만필터에 기반한 GNSS 상시관측소 좌표 시계열의 지진에 따른 편의검출 기법에 관한 연구)

  • Lee, Hungkyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.662-671
    • /
    • 2020
  • It is crucial to manage and maintain the geodetic reference coordinates of GNSS continuously operating reference stations (CORSs) in consideration of their fundamental roles in geodetic control and positioning navigation infrastructure. Earthquake-induced crustal displacement directly impacts the reference coordinates, so such events should be promptly detected, and appropriate action should be made to maintain the target accuracy, including update of the geodetic coordinates. To this end, this paper deals with online schemes for the detection of persistent shifts in the coordinate time-series produced by an automatic GNSS processing system. Algorithms were implemented to test filtered results, such as hypothesis tests of the innovation sequence of a Kalman filter and a cumulative sum (CUSUM) test. The results were assessed by the time-series of coordinates of 14 CORS for two years, including the 2011 Tohoku earthquake. The results show that the global hypothesis test is practical for detecting abrupt jumps, whereas CUSUM is effective for identifying persistent shifts.

Analysis Methods for Measurement of Ammonia Concentration (가스상 암모니아 측정을 위한 분석방법별 특성 연구)

  • Sa, Jae-Hwan;Yoon, Seok-Kyung;Roh, Gi-Hwan;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.43-54
    • /
    • 2008
  • Management and control of ammonia at the sources and ambient largely depend on sampling and measurement techniques. Good sampling and measurement techniques provide high quality data. The main purpose of the study is compare the analytical characteristics of the Indolphenol method which is one of the standard method in Korea with automatic analyzers for continued measuring gaseous ammonia. For comparison with other analytical methods, the verification test was designed to evaluate performance parameters; linearity, absorption efficiency, reproducibility and repeatability test, accuracy, and response time test. $R^2$ of calibration curve using IPM and CLM was very high (value is 1.000), but for EcSM $R^2$ value was estimated to be lower than IPM and CLM (as 0.991). The RSD of the CLM ranged from 0.1 to 2.3% over the nine concentration levels measured, %Ds was 0.1 to 10.7%, and average RA over all the measurements was 3.3%. The RSD of IPM and EcSM was ranged from 1.0 to 8.1, 3.9 to 14.0 respectively, and average RA were 8.71, 4.9% respectively. Rise in response times of EcSM was estimated to be 1 minute. It is found to be more sensitive than response time (which ranged from 2 to 9 minute) of CLM. For ammonia concentration measured using the IPM and the CLM from the same ammonia source, linear regression of IPM versus CLM show a slope of 0.805, an intercept of 637 ppb, and $R^2$ of 0.868.