• 제목/요약/키워드: automatic measuring system

검색결과 355건 처리시간 0.039초

OLE 기반 엔진 구동 부품의 자동 소음 검사 장비 개발 (The Development of an Automatic Noise Inspection System of a Rotating Engine Part Using OLE)

  • 이상철;한성복;최성배
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.968-974
    • /
    • 2004
  • Automakers have been forcing their suppliers to guarantee qualities of parts. Then, the suppliers have met the fundamental quality requirements such as dimensions and functions, but they could not sufficiently satisfy the automakers' noise requirements yet because automatic noise inspection systems were little successfully adopted In mass-production lines. This study tried to develop a system for automatically checking noise radiated from a rotating engine part and filtering parts emitting noise higher than criteria: the upper limits of a overall noise level or a noise spectrum. A commercial noise measurement system was used for measuring noise, and then the noise data was transmitted to a governing program through OLE(object, linking and embedding) functions. The governing program, belonging to a total noise inspection system managed the noise measurement and analysis. This system was successfully adapted for distinguishing bad parts according to the noise criteria.

수동 센서의 오차 최소화를 이용한 실시간 DSC 자동초점 시스템 설계 (A Design of Real-time Automatic Focusing System for Digital Still Camera Using the Passive Sensor Error Minimization)

  • 김근섭;김덕영;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권5호
    • /
    • pp.203-211
    • /
    • 2002
  • In this paper, the implementation of a new AF(Automatic Focusing) system for a digital still camera is introduced. The proposed system operates in real-time while adjusting focus after the measurement of distance to an object using a passive sensor, which is different from a typical method. In audition, measurement errors were minimized by using the data acquired empirically, and the optimal measuring time was obtained using EV(Exposure Value) which is calculated from CCD luminance signal. Moreover, this system adopted an auxiliary light source for focusing in absolute dark conditions, which is very hard for CCD image Processing. Since this is an open-loop system adjusting focus immediately after the distance measurement, it guarantees real-time operation. The performance of this new AF system was verified by comparing the focusing value curve obtained from AF experiment with the one from the measurement by MF(Manual-Focusing). In both case, edge detector was used for various objects and backgrounds.

적응형 측정계획 기반 치과인상 측정 (Dental Impression Measurement Based on an Adaptive Measuring Process Plan)

  • 박상철;정용호;함원경
    • 한국CDE학회논문집
    • /
    • 제18권4호
    • /
    • pp.283-289
    • /
    • 2013
  • Presented in this paper is an adaptive measuring procedure of dental impression using the Structured Light System. While measuring a complex object, such as dental impression, in the reverse engineering, it is not possible to acquire all parts of the scanned surface. Missing scanned data is resulted in holes in a created triangular mesh. The focus of this paper is to introduce an algorithm for automatic identification of additional scanning orientations to fill holes that are created by a default scan. The proposed algorithm was developed by the three major technological requirements: camera visibility, projector visibility, data reliability. In order to satisfy the requirements, the proposed algorithm determines additional scanning orientation from the orientation of a projection plane derived from the average normal vector of boundary triangles.

Computer Testing System for Pumps

  • Xiao, Chongren
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.598-606
    • /
    • 1996
  • Computer testing system for pumps is an automatic measuring and testing system micro computer. There are two functions to this system. 1. Automatically controlling the testing processes. It includes controlling to testing devices, adjusting test points and starting or stopping the pump. 2. Automatically collecting and calculating the testing data. It includes the collection and calculation of the parameters to be measured, printing the testing reports and plotting the testing curves. When using it the measuring accuracy may be improved and the time for testing may be compressed by use the system . So it is used widely on the world. In this paper the basic construction and the work principle and the testing processes are described.

  • PDF

A Study on the Fuzzy Controller for an Unmanned Surface Vessel Designed for Sea Probes

  • Park, Soo-Hong;Kim, Jong-Kwon;Lee, Won-Boo;Jang, Cheol-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.586-589
    • /
    • 2005
  • Recently, the applications of unmanned system are steadily increasing. Unmanned automatic system is suitable for routine mission such as reconnaissance, environment monitoring, resource conservation and investigation. Especially, for the ocean environmental probe mission, many ocean engineers had scoped with the routine and even risky works. The unmanned surface vessel designed for sea probes can replace the periodic and routine missions such as water sampling, temperature and salinity measuring, etc. In this paper, an unmanned surface vessel was designed for ocean environmental probe missions. A classical and an adaptive fuzzy control system were designed and tested for the unmanned surface vessel. The design methodologies and performance of the surface vessel and fuzzy control algorithm were illustrated and verified with this unmanned vessel system designed for sea probes.

  • PDF

보호계전기용 CT의 여자특성 자동측정 시스템 개발 (Development of an Automatic Excitation Characteristics Measurement System of the Protective Relaying CT)

  • 권성원;김문석;김재영;이성하;정재갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.868-869
    • /
    • 2008
  • An automatic excitation characteristics measurement system for the protective relaying current transformer(CT) with accuracy of about 1 % has been developed. The system can be used up to 2 kV and 10 A at power frequency. The developed system can calculate the voltage and current at knee points of $30^{\circ}$ and $45^{\circ}$ tangents in accordance with IEEE standard by the interpolation in log scale. The excitation curve of the CT is plotted in auto-scale simultaneously with measuring rms voltage and current at the secondary of the CT.

  • PDF

액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법 (Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior)

  • 이지영;김경철;김철환;;박현진;김성호;심성웅;조후승
    • 펄프종이기술
    • /
    • 제44권2호
    • /
    • pp.18-28
    • /
    • 2012
  • This study was to develop a novel automatic system for measuring St$\ddot{o}$ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St$\ddot{o}$ckigt sizing degree and contact angle. For the St$\ddot{o}$ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.

Measurement of 3D Spreader Position Information using the CCD Cameras and a Laser Distance Measuring Unit

  • Lee, Jung-Jae;Nam, Gi-Gun;Lee, Bong-Ki;Lee, Jang-Myung
    • 한국항해항만학회지
    • /
    • 제28권4호
    • /
    • pp.323-331
    • /
    • 2004
  • This paper introduces a novel approach that can provide the three dimensional information about the movement of a spreader by using two CCD cameras and a laser distance measuring unit in order to derive ALS (Automatic Landing System) in the crane used at a harbor. So far a kind of 2D Laser scanner sensor or laser distance measuring units are used as comer detectors for the geometrical matching between the spreader and a container. Such systems provide only two dimensional information which is not enough for an accurate and fast ALS. In addition to this deficiency in performance, the price of the system is too high to adapt to the ALS. Therefore, to overcome these defects, we proposed a novel method to acquire the three dimensional spreader information using two CCD cameras and a laser distance measuring unit. To show the efficiency of proposed method, real experiments are performed to show the improvement of accuracy in distance measurement by fusing the sensory information of the CCD cameras and a laser distance measuring unit.

3D Spreader Movement Information by the CCD cameras and the Laser Distance Measuring Unit

  • Lee, Bong-Ki;Lee, Jung-Jae;Kim, Sang-Ju;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.241-245
    • /
    • 2003
  • This paper introduces a method that can derive information about the movement of a spreader and skew in order to drive ALS(Automatic Landing System) in the crane used at a harbor. Some methods that use LDL Corner detectors a kind of 2D Laser scanner sensor or Laser distance measuring units to obtain the information in ALS are used presently. But these have some defects in economic efficiency and performance. Therefore, to correct these defects, we propose a method to acquire the information for the movement of a spreader, skew and sway angle using CCD camera image data and Laser distance measuring unit data.

  • PDF