• Title/Summary/Keyword: automatic measuring system

Search Result 356, Processing Time 0.034 seconds

Development of an Automatic Ophthalmological Outflow Facility Measuring Device (자동 안압 측정장치의 개발)

  • Kim, H.S.;Choi, Gi-S.;Lim, Y.A.;Ki, C.W.;Kim, W.K.;Hong, T.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.178-181
    • /
    • 1996
  • The Outflow facility of eye ball provides crucial informations in the diagnose of ophthalmological glaucoma. Tn this study an ophthalmic outflow facility measuring device is developed and experimentally tested. This system employs pressure sensors and linear positioning device to regulate solution reservoir height, the pressure of eye ball. The experimental result show that the system works well even in harsh environment so that it can be implemented in ophthalmic practice as well as in biomedical research.

  • PDF

Implementation of Fuzzy Classifier and Automatic Turning for Urine Analyzer System using the Strip (스트립을 이용한 뇨분석 시스템의 퍼지 분류기 및 자동 튜닝 구현)

  • Kim, K.W.;Lee, S.J.;Kim, K.N.;Choi, B.C.;Ye, S.Y.;Jun, K.R.;Cho, J.W.;Kim, J.H.;Lee, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.141-142
    • /
    • 1998
  • The urine analysis system implemented to measuring the primary color reaction of urinalysis strip. Fuzzy classifier based on fuzzy theory implemented so as to classify of 9 items in the urinalysis strip and proposed the automatic turning algorithm of mambership function in the fuzzy classifier to progress the reproduction of classify. To evaluation of clinical capability, the fuzzy classifier and automatic turning algorithm apples to standard strip and standard reagent.

  • PDF

Efficiency of Combined Action of Moxalactam and Fosfomycin Determined by MS-2 System Against Penicillin-resistant Staphylococcus aureus Isolates (MS-2 system을 이용한 황색포도구균에 대한 moxalactam과 fosfomycin의 병용효과 측정)

  • Park, Chan-Sok;Ahn, Tai-Hew
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.3
    • /
    • pp.381-385
    • /
    • 1986
  • Twenty strains of penicillin(PC)-resistant Staphylococcus aureus ($MIC{\geqq}32U/ml$) were chosen randomly from recent isolates and submitted to the present experiment to see what effect the combined antibiotic action of moxalactam(MX) and fosfomycin(FM) would bring about on the cells, using MS-2 system. 1. The conventional agar dilution method and the rapid automatic MS-2 system were used in measuring the MICs of MX and FM against each strain and the comparison of the data obtained revealed no significant difference between the two methods in the titer and distribution of the MICs. 2. The automatic MS-2 system was, therefore, used alone in determining the combined growth inhibitory effect of MX and FM because of its more rapidness, and the obtained results were that most of the PC-resistant strains(16 out of 20, 80%) were synergistically inhibited by the two antibiotic combination while additive effect was observed in the remaining 4 strains(20%). 3. Thus, it is suggested that the growth of PC-resistant staphylococcal cells may be synergistically inhibited by MX and FM combination and the efficiency of two antibiotic action as well as MIC of single antibiotic may be more rapidly determined by the MS-2 system than by the conventional method.

  • PDF

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

Study on Adequate Positioning of Environmental Noise Automatic Measuring System in Busan (부산시 환경소음 자동측정망 설치위치의 적정성에 관한 연구)

  • Kim, Hwa-Il;Han, Kyoung-Min
    • Journal of Environmental Policy
    • /
    • v.8 no.1
    • /
    • pp.31-48
    • /
    • 2009
  • To install and operate the Automatic Noise Monitoring Networks reasonably, which able to monitoring environmental noise continually, is an important issue for making decision to urban environment. Noise level is determined by regional environmental factors, that affected by complex urban environment. Therefore, accurate measurement of environmental noise level has top priority to establish and promote appropriate environmental policies. Currently, Automatic Noise Monitoring System is installed for grasping the environmental noise level and preparing basic data for constructing noise-reduction policies. However, this measurement data is recognized not to be able to reflect a sensory noise. The main reason is the lack of reliable measurement data and unreasonable installation site. The main point of this research ought to be the analysis of installed site of noise monitoring system in Busan.

  • PDF

An Electronic System in Automatic Refracto-Keratometer (자동 시각 굴절력 곡률계의 전자 부문 시스템)

  • Seong, Won;Ryu, Gang-Min;Park, Jong-Won
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.669-678
    • /
    • 2002
  • Currently, the domestic interests on the development of eyesight related measuring instruments are being increased. So we are developing such an electronic system of Refracto-keratometer, which contains a software and a hardware both. If this system could inform the examiner of the precise eyesight measuring result from the treatment of the image of optical system, then potentially the number of missed measuring results could be reduced. Our electronic system has been developed from the two areas divided into a software and a hardware. The software area was focused on the more exact eyesight measuring results, using morphological filtering methods and gray-leveled signal enhancing techniques. The hardware area is performing the same functions as the existing other systems. Besides, it provides the embedded software with free variables which could reduce the developing duration sharply as well as enlarge many kinds of application-extensions. Therefore, this electronic system has made effective eyesight measurement possible as the result of reducing the differences applied to sophisticated eyesight measurement.

Development of a New Automatic Image Quality Optimization System for Mobile TFT-LCD Applications (모바일 TFT-LCD 응용을 위한 새로운 형태의 자동화질 최적화 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.17-28
    • /
    • 2010
  • This paper presents a new automatic TFT-LCD image quality optimization system using DSP for the first time. Since conventional manual method depends on experiences of LCD module developers, it is highly labor-intensive and requires several correction steps providing large gamma correction error. The proposed system optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. It contains module-under-test (MUT, TFT-LCD module), PC installed with program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. We have developed a new algorithm using 6-point programmable matching technique with reference gamma curve and applying automatic power setting sequence. Developed algorithm and program are generally applicable for most of the TFT-LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0, and reduce flicker level. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than conventional manual method. We believe that the proposed system is very useful to provide high-quality TFT-LCD and to improve developing process using optimized gamma-curve setting and automatic power setting.

Flatness Control System of the Hot Strip by Using Tension Profile between Stands (스탠드간 장력프로파일을 이용한 열연판 평탄도 제어시스템)

  • 홍완기;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.27-36
    • /
    • 1999
  • To have high flatness quality of hot rolled strip in the hot strip finishing mill train, a new inter-stand tension profile measuring device of segmented looper roll type(coined as Flatness Sensing Inter-stand Looper, FlatSIL) and a new flatness control system have been developed in this study. The device measures the strip tension profile across the strip width and informs the strip wave pattern to new flatness control system where work roll bending mode to relieve the strip wave is determined. The existing automatic shape control system which uses laser type shape-meter installed at the outlet of the last finishing mill stand strip tension between down coiler and last finishig mill since the latent wave concealed by the strip tension between down coiler and last finishing mill stand cannot be measured by the laser distance-meter. Thus the existing shape control system is not able to control the flatness through the full strip length. The new flatness control system, however, works for full strip length during strip rolling as far as the tension profile measuring device and work roll bender are on. With the new flatness control system, work roll bender is automatically controller to minimize the latent wave of the running strip and the flatness quality as well as strip travelling stability has been noticeably improved from strip head through body to tail.

  • PDF

Suggestion of Efficient High Dose Spent Filter Handling and Compaction Equipment

  • Lee, Kyungho;Chung, Sewon;Park, Seonghee;Kim, HuiGyeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.243-253
    • /
    • 2022
  • Spent filters with a high radiation dose rate of 2 mSv·hr-1 or more are not easily managed. So far, the Korean policy for spent filter disposal is to store them temporarily at nuclear power plants until the waste filters can be easily managed. Nuclear power plant decommissioning in Korea is starting with Kori unit 1. Volume reduction of waste generated during decommissioning can reduce the cost and optimize the space usage at disposal site. Therefore, efficient volume reduction is a very important factor during the decommissioning process. A conceptual method, based on the experiences of developing 200 and 800 ton compactors at Orion EnC, has been developed considering worker exposure with the followings a crusher (upgrade of compaction efficiency), an automatic dose measuring system with a NaI(Tl) detector, a shield box, an inner drum to prepare for easy handling of drums and packaging, a 30 ton compactor, and an automatic robot system. This system achieves a volume reduction ratio of up to 85.7%; hence, the system can reduce the disposal cost and waste volume. It can be applied to other types of wastes that are not easily managed due to high dose rates and remote control operation necessity.

Conceptual Design and Development of an Automatic Classification System According to Radioactive Contamination Level Measurement and Contamination of Radioactive Metal Waste (방사성 금속폐기물의 방사능 오염도 측정 및 오염 여부에 따른 자동 분류 시스템 개념설계 및 개발)

  • Sun Beom Kwon;Bo Gil Kim;Jeong Min Yeom;Gyeong Mo Lee;Hong Yeon Lee;Sang Jun Han
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2023
  • Waste generated during the dismantling of nuclear power plants is not only diverse in types such as metal, concrete, soil, but also in a large amount, requiring systematic and efficient management. It is very important to quickly and accurately measure radioactive contamination of wastes generated simultaneously at the decommissioning site, classify them by level, and make decisions so that they can be disposed of in accordance with related laws and regulations. In this paper, for the technical and economic aspects of recycling of radioactive metal waste generated during the dismantling of nuclear power plants, we propose a management system that can measure the radioactive contamination by shape of metal waste at the decommissioning site and automatically classify it according to the presence or absence of contamination. Accordingly, a system for collecting information on metal samples such as weight measurement and shape acquisition of metal waste, measurement of radioactive contamination and identification of nuclides, and an automatic classification system according to radioactivity measurement results were described.