• Title/Summary/Keyword: automatic discharge

Search Result 111, Processing Time 0.023 seconds

The Analysis of Discharge Pressure Noise Characteristics Of Vane Pump for Automatic Transmission (자동변속기용 베인펌프의 토출압 노이즈 특성 해석)

  • Choi, Y.Y.;Choi, H.J.;Lee, S.H.;Jung, W.J.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.33-38
    • /
    • 2010
  • As for an oil hydraulic vane pump of vehicle hydraulic systems, the highest of planning technique required by the acquisition of optimum profile data which can be available to predict noises and vibrations. Pressure pulsation may result in considerable vibration and noise of pump component as well as cavitation in hydraulic system. The influences of the discharge pressure and rotating speed of the vane on the dynamic pressure in chamber surrounding a vane have been investigated. It is very important to predict pressure pulsation in vane pump. This paper presents analysis of technique of vane pump for automatic transmission. The predicted result using AMESim model were good agreement with the experimentally obtained results.

  • PDF

Development of Real-time Simultaneous Discharge Algorithm for Randomly Feeding Object (무작위 이송 개체용 실시간 동시 배출 알고리즘 개발)

  • Kim, S. C.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.145-152
    • /
    • 1999
  • Methods of discharging each graded agricultural product are divided into two according to the type of feeding. One is based on feeding objects using a series of specially designed holders mounted with an equal interval. The other is randomly feeding objects while being isolated without a specific interval. In this paper, a real time simultaneous discharge algorithm, which is good for objects randomly fed individually and for multi-objects located along a series of discharge buckets, was developed. And the developed algorithm was implemented to the controller and the performance was verified using the system developed for dried mushrooms. The discharge system used for the experiment was composed of a variable speed conveyor, a series of double channel bucket mounted along both sides of the conveyor, and a series of air nozzles and optic sensors. Developed algorithm worked perfectly and could be directly used for automatic discharge system for randomly feeding agricultural products.

  • PDF

An Automatic Corona-discharge Detection System for Railways Based on Solar-blind Ultraviolet Detection

  • Li, Jiaqi;Zhou, Yue;Yi, Xiangyu;Zhang, Mingchao;Chen, Xue;Cui, Muhan;Yan, Feng
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.196-202
    • /
    • 2017
  • Corona discharge is always a sign of failure processes of high-voltage electrical apparatus, including those utilized in electric railway systems. Solar-blind ultraviolet (UV) cameras are effective tools for corona inspection. In this work, we present an automatic railway corona-discharge detection system based on solar-blind ultraviolet detection. The UV camera, mounted on top of a train, inspects the electrical apparatus, including transmission lines and insulators, along the railway during fast cruising of the train. An algorithm based on the Hough transform is proposed for distinguishing the emitting objects (corona discharge) from the noise. The detection system can report the suspected corona discharge in real time during fast cruises. An experiment was carried out during a routine inspection of railway apparatus in Xinjiang Province, China. Several corona-discharge points were found along the railway. The false-alarm rate was controlled to less than one time per hour during this inspection.

Discharge Characteristics of the Chusan Spring, Ulleung Island (울릉도 추산용출소의 용출 특성)

  • Cho, Byong-Wook;Lee, Byeong-Dae
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.37-45
    • /
    • 2018
  • The source of Chusan Spring water in the Ulleungdo is the precipitation in the Nari caldera basin, which permeates in the Trachitic pumice and tuff area and moves downward, outflowing at the lithologic boundary between the trachyte and Nari tuff. It is known that the discharge rate of the Chusan Spring is large enough to be used for the small hydroelectric power generation, but the exact discharge rate and hydrogeologic characteristics have not been known. The discharge rates of the Spring were measured 11 times, which ranged from $15,220m^3/d$ to $36,278m^3/d$. The discharge rates, measured by the automatic level recorder, for two-year period, were $20,000{\sim}38,000m^3/d$. The variation of discharge rates did not coincide with rainfall event, but showed daily increases of $3,000{\sim}5,000m^3/d$. The annual discharge rate excluding the evapotranspiration and the surrounding stream discharge corresponded to 70.6% of the annual precipitation of the recharge area. Therefore, meteorological observations at the Nari basin, rather than the Ulleung-do meteorological station, are more appropriate to properly interpret the discharge characteristics of the Chusam Spring and the recharge rate of the basin.

Development of a Zero Discharge and Reuse System for Rural Areas (농촌지역을 위한 무방류 재이용시스템 개발)

  • Hong, Min;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.91-96
    • /
    • 2009
  • This study describes a zero discharge and reuse system developed for rural areas. The purpose of the system is decontamination of used irrigation water for down-stream usage and reuse of wastewater in rural villages for preventing water shortage problem expected to happen in near future. The system consists of anoxic, FES (Ferrous Electricity System), Oxic, Cralifier processes. The main feature of the system is to remove phosphorous by using Fe-ionizing module. Indoor experiments were undertaken with a trial product of the system to test its performance. The removal capacities of T-P, T-N, and BOD were examined. Also the proper time for the replacement of iron plate module was tested as well as the efficiency of T-P removal rate based on the usage of an automatic washing system for the iron plate. As results, the system showed very good water purification performances through obtaining the results of over 90% removal rates from T-P, BOD, and 67% from T-N. The proper time period for replacement of iron plate was maximum 2 years, and also efficiency of T-P removal rate found to be greatly influenced by the usage of an automatic washing system from the test.

Plasma 부하를 갖는 System에서의 Automatching 회로

  • Hwang, Gi-Ung;Kim, Won-Gyu;Lee, Seok-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1985.07a
    • /
    • pp.224-227
    • /
    • 1985
  • During operation of an RF glow discharge system, it can be observed that the reflected power tends to increase in small value, due to changes in the impedance of the system. This problem can be relieved by adding an automatic impedance matching circuit to the system. This paper presents a detailed method of automatically matching the input impedance of a 50 ohm transmission line to an RF glow discharge system at 13.56 MHZ.

  • PDF

Development of an Automatic Liquid Feeder for Early Weaned Piglets (조기이유 자돈용 액상사료 자동급이기 개발)

  • 유용희;정일병;안정대;이덕수;강희설;최희철;전병수;박홍석
    • Journal of Animal Environmental Science
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • This study was conducted to develope an automatic liquid feeder for early weaning piglets and to test the efficacy of the system. The liquid feeder consists of water heating and discharge unit, dry diet storing and discharge unit, mixing and discharge unit, mixed liquid feed-delivering unit, and the central control part which control each unit, feeding frequency and the amount of feeding. For investigating the possibility of practical use, a feeding trial was carried out using eighteen three way crossbred piglets weaned on 19 days of age for the experimental period of six weeks. Experimental diet was provided in liquid form using the automatic liquid feeder for the first three weeks and in dry form for the later three weeks. The water heating and discharge unit exactly supplied warm water by 27 $m\ell$/s, into the mixing unit. The dry diet storing and discharge unit supplied dry feed by 3.7g/s, into the mixing unit. Being compared with the standard growth rate suggested by NRC, average daily gain of the piglets during the first three weeks of liquid feeding was lower by 10%, while it was higher during three weeks of dry feeding and over the whole experimental period by 24 and 17%, respectively. Feed/gain was 1.09, 2.14 and 1.89 for the first 3 weeks, later 3 weeks, and whole period, respectively. Diarrhea was observed for three days from day 3 to day 7 after feeding liquid diet, but no pig died of it. In conclusion, a preliminary test for the newly developed an automatic liquid feeder using 19 days of age weaning piglets showed that the unit was successfully operated without any major problems. Piglets raised on a liquid diet through the unit developed grew less during the first three weeks, but their growth and feed intake were greatly improved thereafter, indicating the developed automatic liquid feeder may be practically used in swine industry.

  • PDF

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

Construction of On-line Partial Discharge Monitoring System for 380kV XLPE Cable in Saudi Arabia (사우디아라비아 380kV XLPE Cable의 신뢰성 확보를 위한 온라인 부분방전 모니터링 시스템 구축)

  • Seo, In-Jin;Lee, Jeon-Seon;Kim, Han-Joong;Kim, Jong-Cheol;Kim, Jung-Yoon;Lee, Hyun-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.95-96
    • /
    • 2008
  • We constructed an on-line PD monitoring system for the 380kV U/G Cable project at the Riyad 9012 substation in Saudi-arabia. The system will be monitoring the termination of the two 380kV XLPE Cables to prevent unexpected failure of the cable insulation. The system had been tested in the laboratory and on-site for detection of various PD signals and reliability of operation. The system distinguish the existence and nonexistence of the partial discharge and then judge the source of partial discharge using automatic PD pattern recognition software.

  • PDF