• 제목/요약/키워드: automated system

검색결과 3,086건 처리시간 0.026초

도심지 근접시공의 자동계측응용 (Application of Automated Measuring System for the Underground Construction in Urban Area)

  • 남순성;정상용
    • 화약ㆍ발파
    • /
    • 제15권2호
    • /
    • pp.53-72
    • /
    • 1997
  • It is impossible to precat the behavior of ground soil and structure accurately during underground construction in urban area or excavation in soft ground area because of difference between the assumed design condition and the actual site condition. Therefore, it must be managed by measuring system and correct the difference by real data. Large scale under ground construction in urban area like a seoul subway project has needed for Intelligent Construction technique, a field of the Engineering Contractor. The automated measuring system is developed for the technique. It is described that the procedure and the method of measuring work with application of the automated measuring system.

  • PDF

배전계통 운영에 대한 자동화 알고리즘 (Automated algorithm on the operation of the power distribution system)

  • 현덕화;강영석;문홍석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.258-261
    • /
    • 1989
  • This paper presents a new algorithm of the operation on power distribution system by automated distribution system (ADS). A performance of this automated algorithm is established to operate the distribution system faster than earlier. We reduced the time and area of power failure by using automation algorithm on ADS.

  • PDF

의료영상 반자동화 영상처리 시스템 (Semi-Automated Image Processing System for Medical Images)

  • 최우영;서명환;유돈식;윤재훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.225-228
    • /
    • 2003
  • The purpose of this paper is to develop a semi -automated system for medical image processing with which tissues or organs from medical images can be segmented and classified by people who have basic knowledge of image processing. In addition, the proposed medical image processing system is independent on types of human tissues or images. In this paper, a new semi-automated image processing system with essential image processing functions for medical images is introduced

  • PDF

인프라-차량(I2V) 통신 기반 서비스 시나리오에 따른 자율협력주행 도로시스템 성능평가 방안 연구 (A Study on the Performance Evaluation of C-ARS(Cooperative Automated Roadway System) in Infrastructure to Vehicle (I2V) Communication Based Service Scenario)

  • 배명환;권오용;김정민;정홍종
    • 한국ITS학회 논문지
    • /
    • 제17권4호
    • /
    • pp.112-123
    • /
    • 2018
  • 자율협력주행 도로시스템은 자율주행차와 V2X 통신으로 연결되어 상호정보를 주고받으며 자율주행차의 안전주행을 지원하는 도로인프라 시스템을 말합니다. 본 연구는 자율협력주행 도로시스템 서비스의 성능평가 방안 제시를 목적으로 하며, 도로인프라에서 자율주행차에 정보를 제공하는 I2V 서비스 중 '작업구간 정보제공 서비스'를 예를 들어, 먼저 서비스에 대한 Use Case 분석과 서비스 성능을 확인하기 위해 필요한 요구사항 및 서비스 범위를 정의하고, 이러한 서비스의 성능평가 수행을 위한 평가시스템을 제안하였다. 또한, 본 연구에서 제안한 평가시스템을 활용하여 '작업구간 정보제공 서비스'의 현장시험을 통해 평가 가능여부를 검증하였다.

응급의료센터 자동약품분배 캐비닛시스템 운영으로 인한 야간 약국업무개선 (Improvement of Night Pharmacy Service by Automated Dispensing Cabinet System Implementation in Emergency Medical Center)

  • 김경희;김선아;이정연
    • 한국임상약학회지
    • /
    • 제28권1호
    • /
    • pp.51-56
    • /
    • 2018
  • Objective: An automated process for medication preparation and dispensing is essential to improve the quality of work. To reduce night pharmacy workload, a new automated dispensing cabinet system was implemented in a hospital emergency medical center. The purpose of this study is to verify that implementation of an automated dispensing cabinet system will influence the efficiency of night pharmacy work. Methods: To evaluate the new system implementation, a retrospective study and survey was performed in the Ewha Womans University medical center. We compared the dispensing and near-miss error rates between the automated dispensing cabinet system and a night pharmacy. The degree of satisfaction of night shift workers with the new system was surveyed. Results: This study showed significantly reduced dispensing rates of night medications (56.1% and 37.3%; p < 0.01) and near-miss night medications (0.27% and 0.17%; p<0.01). Thirty-two persons responded to the survey, and the satisfaction score for the new system was 4.0 (${\pm}0.8$). The scores were high in order of efficiency, management, and convenience. Time requirement was also reduced because of the simple step of only reviewing in the pharmacy with the new system. Conclusion: Due to system implementation, workload was reduced and time was saved for not only night shift workers but also patients receiving emergency discharge medicine. It was suggested that this will have a positive effect on pharmacist medical service and patient safety.

배관 용접부 자동 초음파 결함 영상 보정 시스템 구현 (Implementation of An Automated Ultrasonic Flaw Imaging System for the Inspection of Pipe Welding)

  • 김한종;박종훈;김철원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.556-559
    • /
    • 2008
  • 용접부 내에 존재하는 결함의 형태, 위치, 크기 등의 정보를 정량적으로 파악하기 위하여 초음파 탐상 검사가 많이 활용되는데, 최근 들어 용접부의 결함 탐상을 위해, 검사과정을 기계적 스캐너로 자동화한 자동 초음파 탐상 시스템이 많은 산업분야에서 활용되고 있고, 특히 배관 용접부의 건전성 평가를 위한 비 파괴안전진단에서 그 활용 폭이 커지고 있다. 배관 용접부 건전성 제고를 위해 본 연구를 통해 용접부 결함 영상화 프로그램을 구현하였다.

  • PDF

Development of an AutoFlat program for the acquisition of effective flat images in the automated observation system

  • Yoon, Joh-Na;Kim, Yonggi;Kim, Dong-Heun;Yim, Hong-Suh
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.327-334
    • /
    • 2013
  • The purpose of this study is to develop an observation program for obtaining effective flat images that are necessary for photometric observation. The development of the program was achieved by improving the existing method for obtaining twilight flat images. The existing method for obtaining twilight flat images acquires flat images by observing the sky light after sunset or light before sunrise. The decision of when to observe flat images at each night is solely dependent on the judgment of an observer, and thus the obtained flat images for particular nights may not be clean. Especially, in the case of the observatories where an automated observation system is in operation, there is a difficulty that an observer should pay attention during sunrise and sunset in order to obtain flat images. In this study, a computer program is developed to improve this inconvenience and to efficiently perform photometric observation in the observatories where an automated observation system is applied. This program can obtain flat images by calculating the time for obtaining flat images automatically and the exposure time using a numerically calculated function. When obtaining twilight flat images at dusk and at dawn, the developed program performs automated observation and provides effective flat images by acquiring appropriate exposure time considering the sunrise and sunset times that vary depending on the day of observation. The code for performing this task was added to Obs Tool II (Yoon et al. 2006), which is the automated observation system of the Chungbuk National University Observatory, and the usefulness of the developed program was examined by performing an actual automated observation. If this program is applied to other observatories where automated observation is in operation, it is expected that stable and high-quality flat images could be obtained, which can be used for the pre-processing of photometric observation data.

돼지의 자동 비접촉 체중계측 시스템 개발 (Development of a Automated Noncontact Weighing System for Pigs)

  • 임영일
    • 한국축산시설환경학회지
    • /
    • 제6권1호
    • /
    • pp.23-30
    • /
    • 2000
  • A automated noncontact weight system for pigs consisted of a CCD-type video camera and 10 photo sensors connected to a computer. In the experiment 20 pigs(Large Yorkshire $\times$ Landrace breed) weighing from 95kg to 115kg were used. Pig's original image data was transformed to a binary image an image excluding head and tail portion from the whole binary image and the area of pig was calculated. Then pig's volume was calculated by multiplying the area by the body hight measured with photo sensors. The correlation equation between the above volume(x) and pig's weight was y=0.0007 x -9.2152($R^2$=0.9965) Performance of a automated noncontact weighing system for pigs was tested with this equation. The results showed $\pm$0.65kg average error and 1.63kg maximum error. It was concluded that performance of a automated noncontact weighing system is excellent.

  • PDF

A Constraint Programming-based Automated Course Timetabling System

  • Hwang, Junha
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권4호
    • /
    • pp.27-34
    • /
    • 2019
  • The course timetabling problem is a kind of very complex combinatorial optimization problems, which is known as an NP-complete problem. Sometimes a given course timetabling problem can be accompanied by many constraints. At this time, even if only one constraint is violated, it can be an infeasible timetable. Therefore, it is very difficult to make an automated course timetabling system for a complex real-world course timetabling problem. This paper introduces an automated course timetabling system using constraint programming. The target problem has 26 constraints in total, and they are expressed as 24 constraints and an objective function in constraint programming. Currently, we are making a timetable through this system and applying the result to the actual class. Members' satisfaction is also much higher than manual results. We expect this paper can be a guide for making an automated course timetabling system.

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.