• 제목/요약/키워드: attenuation measurement

검색결과 390건 처리시간 0.024초

철도교통소음의 특성에 관한연구 (A Study on the Characteristics of Railroad Traffic Noise)

  • 최형일;박상일;염동익
    • 한국환경과학회지
    • /
    • 제16권7호
    • /
    • pp.771-778
    • /
    • 2007
  • This study has been conducted to achieve the following objectives: First, in order to understand the horizontal propagation and attenuation characteristics for the railroad traffic noise, we selected areas within 100 meters away from the railroad and then selected Saemaul-ho and Mugoongwha-ho as the subjects for our experiment. In this way, we analyzed the horizontal propagation and attenuation characteristics for the traffic noise occurring in diversified areas. Second, in order to understand the vertical propagation and attenuation characteristics for the railroad traffic noise, we measured and analyzed the distributional characteristics of vertical sound pressure levels on each floor of multi-storied apartment buildings according to changes of traffic load and types, and the existence or nonexistence of soundproof walls. For the case of the railroad traffic noise, we also selected Samaul-ho and Mugoongwha-ho as the subjects for our experiment, and we measured and analyzed the different noise levels on each floor of multi-storied apartment buildings from the soundproof wall. The results of Horizontal propagation and attenuation characteristics for the railroad traffic noise are as follows: In cases of the flat land, cutting land, and bridge area, as distance increases, the sound pressure level steadily decreases. The sound pressure level for the bridge area is higher than that of the flat land with a measurement of $5.5{\sim}10.2\;dB(A)$. Vertical propagation and attenuation characteristics for the railroad traffic noise are as follows: The amount of sound pressure level decrease is $14.2{\sim}14.8\;dB(A)$ for Samaul-ho and $13.5{\sim}14.3\;dB(A)$ for Mugoongwha-ho when measuring the vertical sound pressure levels at heights lower than 4.5 m, which indicates a fairly large decrease. At 6 m, the amount of decrease is 8.6 dB(A) for Samaul-ho and 8.2 dB(A) for Mugoongwha-ho, which indicates a small decrease.

2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구 (A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel)

  • 박익근;박은수;김정석;김현묵;권숙인;변재원
    • 비파괴검사학회지
    • /
    • 제21권4호
    • /
    • pp.439-445
    • /
    • 2001
  • 재료나 설비의 고온 장시간 사용으로 인하여 발생되는 재질열화 평가에는 파괴적인 방법이 널리 사용되고 있으며, 신뢰도가 높다. 그러나, 시험편의 채취가 어렵고 많은 경비와 시간이 소요된다. 전기저항법, 레프리카법, 바크하우젠 노이즈법, 전기화학적방법, 초음파법 등과 같은 비파괴적인 열화손상 평가 방법이 주목을 받고 있다. 본 연구에서는 2.25Cr-1Mo 강을 $630^{\circ}C$에서 장시간 등온열처리로 모의 열화시험편을 제작하고, 고온설비부재에서 발생되는 미세조직의 변화와 고주파 초음파의 전파특성(감쇠계수)과의 일대일 상관관계를 규명하여 초음파 비파괴평가에 의한 열화도 평가의 유용성 유모를 실험적으로 검증하였다. 그 결과 2.25Cr-1Mo 인공열화재의 경우 열화가 진행됨에 따라 탄화물의 석출 및 조대화가 일어나며 초음파 감쇠계수는 증가하는 경향을 나타내었으며, 그 정도는 침상의 탄화물이 거의 소멸되는 1,000시간 이후에 초음파 감쇠계수가 급격히 증가하는 매우 좋은 상관성을 나타내었다.

  • PDF

REVIEW OF GROUNDWATER CONTAMINANT MASS FLUX MEASUREMENT

  • Goltz, Mark N.;Kim, Seh-Jong;Yoon, Hyouk;Park, Jun-Boum
    • Environmental Engineering Research
    • /
    • 제12권4호
    • /
    • pp.176-193
    • /
    • 2007
  • The ability to measure groundwater contaminant flux is increasingly being recognized as crucial in order to prioritize contaminated site cleanups, estimate the efficiency of remediation technologies, measure rates of natural attenuation, and apply proper source terms to model groundwater contaminant transport. Recently, a number of methods have been developed and subsequently applied to measure contaminant mass flux in groundwater in the field. Flux measurement methods can be categorized as either point methods or integral methods. As the name suggests, point methods measure flux at a specific point or points in the subsurface. To increase confidence in the accuracy of the measurement, it is necessary to increase the number of points (and therefore, the cost) of the sampling network. Integral methods avoid this disadvantage by using pumping wells to interrogate large volumes of the subsurface. Unfortunately, integral methods are expensive because they require that large volumes of contaminated water be extracted and managed. Recent work has investigated the development of an integral method that does not require extraction of contaminated water from the subsurface. We begin with a review of the significance and importance of measuring groundwater contaminant mass flux. We then review groundwater contaminant flux measurement methods that are either currently in use or under development. Finally, we conclude with a qualitative comparison of the various flux measurement methods.

부유물 농도 변화에 따른 초음파 신호의 감쇠계수 측정 (Measurements of Ultrasound Attenuation Coefficient at Various Suspended Sediment Concentrations)

  • 이찬길;최지웅
    • 한국음향학회지
    • /
    • 제33권1호
    • /
    • pp.1-9
    • /
    • 2014
  • 하구와 연안은 육지와의 근접성으로 인해 강이나 하천 등에 의한 퇴적물 공급이 외해에 비해 활발하게 이루어지는 지역으로서 때로는 고농도의 부유퇴적물이 조성되기도 한다. 부유퇴적물은 외부 작용으로부터 쉽게 환경이 변하는 특성을 가지기 때문에 부유물층 탐지 및 연구를 위해 주로 음향 장비를 이용하지만 고농도 부유물 환경에서는 음파감쇠가 심하고, 이로 인해 음파의 이동 거리가 크게 감소한다. 따라서 부유물 환경에 대한 연구를 하기 위해서는 부유물 환경 특성과 주파수 변화에 따른 감쇠계수 특성을 파악하는 것이 매우 중요하다. 본 논문에서는 간이수조 내에서 고령토 가루를 이용하여 다양한 농도의 부유물을 조성한 후, 초음파 대역 (3.5, 5, 7.5 MHz)에 대한 감쇠계수를 측정하였으며, 감쇠계수 모델과 비교하였다. 감쇠계수 모델의 입력인자인 부유물의 평균입자 크기를 다양하게 변화시키며 실측값과 비교한 결과 평균 입자크기 (D50)을 기준으로 약 ${\pm}20%$ 범위 내에서 비교적 일치하였다. 이러한 오차 발생 원인은 부유물은 다양한 크기의 입자들로 구성되어 있으며, 음파 감쇠는 특정주파수에 우세한 영향을 미치는 크기의 입자분포에 영향을 받기 때문으로 판단된다.

전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구 (Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance)

  • 허태훈;조승현;안봉영;임종수
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.7-13
    • /
    • 2013
  • 철강 생산 제품 중 강선 (steel wire rod)은 제조 과정 중 종방향으로 미세한 표면 결함이 매우 빈번하게 발생하는데 이중 깊이가 수 십 마이크로미터 이상인 결함들은 최종 생산품의 불량을 유발하는 심각한 원인이 되고 있다. 이와 같은 이유로 강선의 제조 단계에서 표면의 미세 결함의 깊이를 평가하는 방법의 개발이 절실히 요구된다. 표면 미세 결함을 평가할 수 있는 여러 가지 방법 중에서, 본 연구에서는, 전자기 음향공진법의 적용 가능성을 고찰하고자 한다. 전자기 음향 공진 (electromagnetic acoustic resonance, EMAR)은 전자기 음향 트랜스듀서 (electromagnetic acoustic transducer, EMAT)을 이용하여 시편의 공진 특성을 측정하는 방법으로서, 대상의 작은 변화에도 민감하게 반응하고 비접촉 측정이 가능하여 현장 적용에 용이하다는 장점이 있다. 전자기 음향 공진 실험을 통하여 표면 미세결함과 잔향특성의 변화를 관찰하여 깊이 약 100 마이크로미터 내외의 결함은 탐상 가능함을 확인하였다.

Measurement Allocation by Shapley Value in Wireless Sensor Networks

  • Byun, Sang-Seon
    • Journal of information and communication convergence engineering
    • /
    • 제16권1호
    • /
    • pp.38-42
    • /
    • 2018
  • In this paper, we consider measurement allocation problem in a spatially correlated sensor field. Our goal is to determine the probability of each sensor's being measured based on its contribution to the estimation reliability; it is desirable that a sensor improving the estimation reliability is measured more frequently. We consider a spatial correlation model of a sensor field reflecting transmission power limit, noise in measurement and transmission channel, and channel attenuation. Then the estimation reliability is defined distortion error between event source and its estimation at sink. Motivated by the correlation nature, we model the measurement allocation problem into a cooperative game, and then quantify each sensor's contribution using Shapley value. Against the intractability in the computation of exact Shapley value, we deploy a randomized method that enables to compute the approximate Shapley value within a reasonable time. Besides, we envisage a measurement scheduling achieving the balance between network lifetime and estimation reliability.

초음파탐상(超音波探傷)에서의 감도차(感度差) 측정(測定) 연구(硏究) (Study on the Sensivivity Difference Measurement by Ultrasonic Testing)

  • 정용무;안희성;이연필
    • 비파괴검사학회지
    • /
    • 제2권1호
    • /
    • pp.5-9
    • /
    • 1982
  • Experiments were performed according to ultrasonic attenuation measurement and comparison method of DAC curve to analyze the difference between PSI and 2nd ISI ultrasonic testing results. Smaller error was found by comparison method of DAC curve, and that method was more useful practically.

  • PDF

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가 (Development of the IRIS Collimator for the Portable Radiation Detector and Its Performance Evaluation Using the MCNP Code)

  • 지영용;정근호;이완로;최상도;김창종;강문자;박상태
    • 방사성폐기물학회지
    • /
    • 제13권1호
    • /
    • pp.55-61
    • /
    • 2015
  • 방사선검출기를 이용한 고방사성물질의 측정이나 방사선사고 등의 신속한 대응을 위하여 주위의 선량률 준위에 따라 크기별로 여러 종류의 콜리메이터들을 구비해야 하며, 이는 무거운 콜리메이터의 특성상 효율적인 현장 측정에 심각한 장애가 될 수 있다. 본 연구에서는 콜리메이터의 모양을 카메라의 렌즈 조리개 형식으로 제작하여 사용자가 직접 카메라 렌즈를 돌려 초점을 맞추듯이 콜리메이터의 내경을 조절하고 방사선의 감쇄율을 쉽게 알아볼 수 있도록 IRIS형 콜리메이터를 제작하였다. 먼저, 콜리메이터를 위상을 달리한 2 중의 텅스텐 셔터 구조로 제작하여 기계적 공차에 의한 방사선의 침투를 차단하고자 하였다. 그리고 셔터의 재질별로 콜리메이터 내경에 따른 방사선 감쇄율을 MCNP 코드를 이용하여 계산함으로써 이론적인 성능평가를 수행하였다. 계산된 내경의 크기별 감쇄율을 콜리메이터 외부 눈금링에 표시함으로써, 카메라 렌즈에 표시된 배율과 같은 방법으로 사용자가 해당 표시지점으로 콜리메이터 내경을 조절하였을 때, 방사선의 세기가 얼마만 큼 감소되는지 쉽게 알아볼 수 있도록 구현하였다. 끝으로 개발된 IRIS형 콜리메이터를 장착한 소형 방사선검출기를 현장 측정에 활용할 경우, 콜리메이터의 교체 없이 주위 방사선의 세기에 따라 콜리메이터 내경을 적절한 크기로 신속히 교체가 가능하며, 방사선 세기의 감쇄 정도를 쉽게 알아보게 함으로써 신속하고 정확한 대처가 가능할 것으로 판단된다.

GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이 (Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT)

  • 김진수;이재성;이동수;박은경;김종효;김재일;이홍재;정준기;이명철
    • 대한핵의학회지
    • /
    • 제39권3호
    • /
    • pp.182-190
    • /
    • 2005
  • 목적: CT기반 감쇠보정 영상의 표준섭취계수(Standard Uptake Value:SUV)가 $^{137}Cs$ 기반 감쇠보정 영상의 SUV보다 높다. 이 연구에서는 이러한 오차가 생기는 원인을 밝히고자 감쇠계수가 정확하게 변환되었는지 여부를 관심영역 분석을 통하여 평가하였다. 대상 및 방법: Philips GEMINI PET/CT는 X-ray CT (평균 40 keV) 혹은 $^{137}Cs$ (662 keV) 투과영상을 감쇠보정에 이용하는데 GEMINI PET/CT에서 사용하는 각각 선원의 에너지는 511 keV에서 얻은 감쇠계수와 틀리기 때문에 스캐너 내부에 장착된 감쇠계수 변환 알고리즘을 이용하여 511 keV에 해당하는 감쇠계수 값으로 변환된 감쇠지도를 사용하므로 감쇠계수의 변환이 정확하게 이루어졌는지 평가하는 것이 중요하다. 각각의 실험과정은 다음과 같다. 먼저 시스템 성능평가 팬텀 CT 투과 영상을 사용하여 Hounsfield units (HU)값을 측정하였다. 다음으로 NEMA 타원형 ECT 팬텀의 CT, $^{137}Cs$ 투과영상을 얻어 $^{68}Ge$ 투과선원을 장착한 Siemens ECAT EXACT 47 PET 스캐너에서 얻은 팬텀 투과 영상과 비교하여 감쇠계수가 511 keV에 해당하는 감쇠계수로 잘 변환되었는지 측정하였고 Gammex 467 electron density CT 팬텀의 CT, $^{137}Cs$ 투과영상에서 관심영역 분석을 하여 다양한 전자밀도 값에 대한 감쇠계수 변환의 정확성을 평가하였다. 또, 재구성한 영상에 미치는 영향을 평가하기 위하여 정상 및 병적 조직에서 CT, $^{137}Cs$ 기반 감쇠계수와 표준섭취계수를 비교하였다. 결과: CT에서 측정한 HU는 신뢰할 수 있는 값임을 확인하였으나 전자밀도와 원자번호가 큰 영역에서 CT 기반 감쇠계수에 오차가 있었는데 NEMA 타원형 ECT 팬텀 실험결과에 의하면 뼈 영역에서 오차는 11%이었다. 임상데이터에서도 마찬가지로 CT를 이용하여 얻은 감쇠계수가 $^{137}Cs$을 이용하여 얻은 감쇠계수보다 낮았고 전자밀도와 원자번호가 큰 영역에서 오차가 컸다. 그러나, 표준섭취계수는 $^{137}Cs$를 사용하여 감쇠보정을 한 영상의 값이 CT를 이용하여 감쇠보정을 한 값보다 오히려 낮았고 표준섭취계수의 백분율 차이는 $6.6{\sim}52.7%$이었다. 결론: CT의 HU가 정확함에도 불구하고 뼈 영역에서 CT 투과영상을 기반으로 한 감쇠계수의 변환이 부정확하고 CT 및 $^{137}Cs$ 투과영상을 기반으로 얻은 표준 섭취계수에 차이가 있으므로 이에 관한 추가적인 연구가 필요할 것으로 생각한다.