Effects of Histamine Pretreatment on the subsequent Noradrenaline-induced Contraction and $K^+-Contracture$ in Rabbit Renal Artery (가토 신동맥의 고농도 Histamine에 의한 노아드레날린 유발 수축 및 K-경축 약화 기전)

  • Lee, Sung-Woo;Kim, Se-Hoon;Chang, Seok-Jong;Park, Hae-Kun
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.351-361
    • /
    • 1989
  • The contraction of renal arterial strip by no.epineph.me (NE) or 40 mM $K^+$ were Significantly attenuated after histamine $(10^{-5}\;M)-induced$ contraction. The mechanisms of this phenomenon were investigated in the helical strips of isolated renal artery with the measurement of isometric tension. The arterial strip was immersed in the tris-buffered Tyrode's solution which was equilibrated with 100% $O_2\;at\;35^{\circ}C$. The contraction was induced by NE or 40 mM $K^+$ during the recovery from the histamine-induced contraction which lasted for 15 minutes. The contraction by NE was also attenuated in the $Ca^{2+}-free$ Tyrode's solution and the increase of contraction by addition of 2 mM $Ca^{2+}$ was attenuated as well. This attenuation phenomenon was not observed in the presence of low concentration $(3{\times}10^{-7}\;M)$ of histamine. This attenuation was not affected by destruction of endothelium, pretreatment with papaverine or propranolol. This attenuation was partially inhibited by pretreatment of ouabain or in low $K^+(0.5 mM)$ Tyrode's solution. But the attenuation in the $Ca^{2+}-free$ Tyrode's solution was not inhibited. Furthermore this attenuation was completely blocked by pretreatment of djphenhydramine $(H_1-receptor blocker)$ and potentiated by pretreatment of cimetidine $(H_2-receptor\;blocker)$. This attenuation Phenomenon was disappeared after recovery of 1 hour. From the above results, it is suggested that the attenuation phenomenon may be resulted partially from the activation of $Na^+-K^+$ exchange pump and partially from the depletion of intracellular $Ca^{2+}$ pool after the histamine-induced contraction mediated through $H_1-receptor$ function.

  • PDF

Half Wavelength Partial H-Plane Filter with Inverters having Attenuation Poles (감쇄극 인버터를 이용한 반파장 Partial H-Plane 여파기)

  • Kim, Dong-Jin;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • This paper presents half wavelength partial H-plane filters with multiple attenuation poles using narrow H-plane slot of evanescent waveguide. The narrow H-plane slot operates as an admittance inverter o( the bandpass filter and, simultaneously, generates an attenuation pole at particular frequency. Therefore, proposed filters with attenuation poles are simply implemented without any additional coupling and extra modification of the structure. The number of attenuation poles of the filters equals to that of the H-plane slots. Moreover, proposed filters are compact waveguide filter since ones are embodied by partial H-plane waveguide which has 1/4 cross section of conventional waveguide. The third and fourth-order half wavelength filters having 4 and 5 attenuation poles, respectively, are designed in H-band and their frequency responses are confirmed by simulation and measurement.

Noise Measurement by Percentage of Effective Linear Attenuation Coefficient of Water in CT Image of AAPM CT Performance Phantom (AAPM CT 성능 팬텀의 CT영상에서 물 유효선감쇠계수의 백분율에 의한 노이즈 측정)

  • Jong-Eon, Kim;Sang-Hun, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.771-778
    • /
    • 2022
  • The purpose of this study is to present a method of measuring noise by the percentage of effective line attenuation coefficient of water that can be used for quality control of CT image noise using AAPM CT performance phantom in clinical practice. In the CT images obtained by scanning the AAPM CT performance phantom with a 120 kVp CT X-ray beam, the mean CT number was measured for each pin and water in the CT number linearity insert part. The effective energy was determined as the photon energy with the largest correlation coefficient from the correlation coefficients of the linear regression analysis of the measured mean CT number for each pin and water and the linear attenuation coefficient for each photon energy. And for water and acrylic, the contrast scale was calculated as 0.000188 cm-1 · HU-1 from the measured mean CT number and effective line attenuation coefficient. Using the calculated contrast scale, the effective line attenuation coefficient of water, and the standard deviation measured in the water of the alignment pin part of the AAPM CT performance phantom, The noise measurement value by the percentage of effective line attenuation coefficient of water obtained 0.31 ~ 0.52% in the range of 100 ~ 300 mAs.

Seismic attenuation from VSP data in methane hydrate-bearing sediments (메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠)

  • Matsushima, Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recent seismic surveys have shown that the presence of methane hydrate (MH) in sediments has significant influence on seismic attenuation. I have used vertical seismic profile (VSP) data from a Nankai Trough exploratory well, offshore Tokai in central Japan, to estimate compressional attenuation in MH-bearing sediments at seismic frequencies of 30-110 Hz. The use of two different measurement methods (spectral ratio and centroid frequency shift methods) provides an opportunity to validate the attenuation measurements. The sensitivity of attenuation analyses to different depth intervals, borehole irregularities, and different frequency ranges was also examined to validate the stability of attenuation estimation. I found no significant compressional attenuation in MH-bearing sediments at seismic frequencies. Macroscopically, the peaks of highest attenuation in the seismic frequency range correspond to low-saturation gas zones. In contrast, high compressional attenuation zones in the sonic frequency range (10-20 kHz) are associated with the presence of methane hydrates at the same well locations. Thus, this study demonstrated the frequency-dependence of attenuation in MH-bearing sediments; MH-bearing sediments cause attenuation in the sonic frequency range rather than the seismic frequency range As a possible reason why seismic frequencies in the 30-110 Hz range were not affected in MH-bearing sediments, I point out the effect of thin layering of MH-bearing zones.

The Study on the Head and Neck Phantom for Quality Assurance of Intensity Modulated Radiotherapy (세기변조방사선치료의 정도관리를 위한 두경부 팬톰 제작에 관한 연구)

  • Shin Dongho;Park Sung-Yong;Kim Joo Young;Lee Se Byeong;Cho Jung Keun;Kim Dae Yong;Cho Kwan Ho
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.39-46
    • /
    • 2005
  • For the QA of IMRT treatment of head and neck cancer by using M3 (BrainLAB Inc. Germany), it is not easy to measure delivery dose exactly because the dose attenuation appears by the couch according to the position of table and gantry. In order to solve this problem, we fabricated head and neck phantom which would be implemented on the couch mount of Brain Lab Inc. We investigated dose attenuation by the couch and found the difference of dose distribution by the couch, in the applying this phantom to the clinic. After measurement, we found that point dose attenuation was 35% at maximum and dose difference was 5.4% for a point dose measurement of actual patient quality assurance plan.

  • PDF

Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals (2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정)

  • 정종수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images (초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석)

  • Hye-Ri, Chun;Hyon-Chol, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2022
  • This study attempted to find out the degree of agreement between ultrasound image findings along with analysis of attenuation index and scatter distribution index values within tissues through quantitative measurement analysis using liver ultrasound images. From August 2022 to October 2022, liver ultrasound was performed on 45 patients who were suspected of having fatty liver and who received a prescription for liver ultrasound. As a result of the study, as a result of analyzing the agreement between the ultrasound image findings and the tissue attenuation index, the Kappa value was 0.82 (p<0.05), showing a very high agreement between the two examination methods. In addition, as a result of the agreement analysis between the ultrasound image findings and the scatter distribution index in the tissue, the Kappa value was 0.642 (p<0.05), showing high agreement between the two examination methods. At the time of fat liver prediction, the use of liver ultrasound findings and quantitative ultrasonography techniques, such as intra-tissue attenuation index and intra-tissue scatter distribution index, may be helpful in determining the degree of progression of fatty liver patients.

Measurement of DS-CDMA Propagation Distance in Underwater Acoustic Communication Considering Attenuation and Noise

  • Lee, Young-Pil;Moon, Yong Seon;Ko, Nak Yong;Choi, Hyun-Taek;Huang, Linyun;Bae, Youngchul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.20-26
    • /
    • 2015
  • It is very difficult to design an underwater communication system because of multipath, Doppler effects, noise, and attenuation. These factors lead to errors in the communication performance and maximum propagation distance. In this study, we calculate the distance that can be realized using the direct-sequence code division multiple access (DS-CDMA) technique with direct-sequence spread spectrum (DSSS) in an underwater communication system considering only the attenuation and noise. We also compare the estimated and calculated propagation distances obtained for several different scenarios.

ULTRASONIC PROPERTY OF RADISH UNDER COMPRESSION LOAD

  • Lu, F.M.;Huang, W.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.543-550
    • /
    • 2000
  • The objective of this research was to study the effect of contact force of ultrasonic probe on the ultrasonic attenuation measurement of radish. The relationship between ultrasonic attenuation (y) and contact force (x) for radish can be expressed as equation y=a+bLn(x), where a=8.7194+2.l68x(porosity) and b =-9.9188+0.0075 ${\times}$ (volume). The relationship between ultrasonic power spectrum (y) and contact force (x) for radish is also represented by equation y=a+bLn(x), where a= 60.l965-1.47l4${\times}$(porosity). The coefficient b has no significant relation with radish properties.

  • PDF

Ultrasonic Wave Attenuation Measurement for Damage Characterization of Concrete (콘크리트의 손상 평가를 위한 초음파 감쇠량 측정법)

  • Kwak, Hyo-Gyoung;Yim, Hong-Jae;Kim, Jae-Hong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.85-86
    • /
    • 2009
  • A nondestructive test method based on the self-compensating frequency response function is proposed in this paper to quantitatively measure the attenuation in concrete materials. Since the proposed technique measures inherent attenuation of material itself, more stable experimental results can be expected. In advance, comparison of the experimental results to those obtained by other methods shows the repeatability and accuracy of the proposed technique.

  • PDF