• Title/Summary/Keyword: attenuation measurement

Search Result 390, Processing Time 0.032 seconds

Thickness Control of Cold-Rolling Mills with Roll Eccentricity (롤편심을 포함한 냉간 압연시스템의 두께제어)

  • 김승수;김종식;황이철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.248-254
    • /
    • 1996
  • A disturbance rejection controller using eccentricity filtering and LQ control techniques is proposed to alleviate significantly the effect of roll eccentricity in multivariable cold-rolling processes. Fundamental problems such as process time delay inherent in exit thickness measurement and non-stationary characteristics of roll eccentricity signals can be overcome by the proposed control method. The filtered instantaneous estimate of roll eccentricity may be exploited to improve instantaneous estimate of the exit thickness variation based on roll force and roll gap mearsurements, and a feedforward compensator is augmented as a reference for a gaugemeter thickness estimator. And, LQ feedback controller is combined with eccentricity filter for the attenuation of the exit thickness variation due to the entry thickness variation. The simulation results show that eccentricity components have been significantly eliminated and simultaneously other distrubances also have been attenuated.

  • PDF

Measurement and Assessment of Hand-arm Vibration due to Grinders (그라인딩 작업에 의한 수완계 진동 계측 및 평가)

  • 이종문;박진화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1032-1037
    • /
    • 2003
  • This work measured the hand-transmitted vibration due to shipyard worker's grinding and assessed the vibration exposure for predicted 10% prevalence of vibration-induced white finger in a group of exposed persons according to test procedure of ISO 5349-1. And also the transmissibility performance of resilient material, mainly applied to anti-vibration gloves in present market was measured on the basis of ISO 13753 and confirmed that the material would Probably not provide greater attenuation below 30㎐, the dominant frequency range of hand-transmitted vibration due to grinder.

  • PDF

Analysis in Measurements of Gastric Emptying Time (위 배출시간 측정의 분석방범에 대한 연구)

  • Lee, Choon-Ho;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.35-38
    • /
    • 1997
  • Scintigraphic measurement of gastric emptying time has been reported to be influenced by the variation in depth of radionuclide within the stomach. This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between anterior image, the total anteroposterior Image and the tissue attenuation correction(geometric mean). A dual-head scintillation camera(ADAC, USA) was used to investigate effect of such changes. We were performed 16 normal subject gastric emptying studies with $^{99m}TC$ labelled scramble egg, milk and solid meal(610 Kcal, 300 g) The results are as follows; On anterior Image, $T_{1/2}$ emptying time was delayed by 5 min, 6.5%(range $3{\sim}18\;min,\;5{\sim}31.4%$) compared with the geometric mean. But there was no different gastric emptying time between the total anteroposterior image and geometric mean. Therefore, if will be useful to use the method of geometric mean or the total anteroposterior image to evaluate the gastric emptying time accurately.

  • PDF

Field Trial of the Korean-Made 45Mb/s Optical Fiber Communication System (45Mb/s 국산 광직유 통신 시스템의 현장 시험)

  • 강민호;이용택;이상호;이만섭;유강희;박희갑;이성은;추흥로
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.2
    • /
    • pp.50-58
    • /
    • 1983
  • In this paper, a field trial of the Korean-made optical fiber communication system is described. This system was installed between Gu-Ro and Ann-Yang telephone offices on November 1981, and carries a 44.7Mb/s NRZ signal(672 voice channel equivalent). For this trial, optical fiber cable, optical terminal equipment, optical repeater, fusion splicer and measurement equipment have been developed. Employing graded index optical fiber at a wave length of $0.85\;\mu\textrm{m}$, average optical attenuation and splicing losses of 3.6 dB/km and 0.4 dB, resectively, were realized. With link margins of 8~20dB and bit error rate of less than $10^{-10}$, this system has been carrying live traffic between Seoul and Ann Yang telephone offices.

RF Channel Characteristics of the Medium-voltage Power Line for PLC (전력선통신을 위한 중 전압용 전력선의 RF채널 특성)

  • Kim, Seon-Hyo;Kim, Gwan-Ho;Lee, Hyeong-Cheol;Sin, Cheol-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

A study on underwater optical wireless communication link capability in the Bay of Bengal

  • Sathyaram, V.;Prince, Shanthi;Vedachalam, N.
    • Ocean Systems Engineering
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • The paper presents a numerical underwater channel model developed in MATLAB for estimating the optical link budget between a light emitting diode (LED) based optical transmitter and a photo diode (PD) receiver when operated in the harbor, coastal and deep waters locations in the Bay of Bengal. The water samples are collected at different locations in the Bay of Bengal using a water sampler during an offshore research cruise. The optical attenuation, the main inherent parameter determining the range of the optical communication link is identified for the different waters using an underwater irradiance measurement system in the laboratory. The identified parameters are applied to the numerical model and found that a 10 W LED and a photo diode based system can provide the optical budget required for a horizontal underwater communication range of about 0.5, 14 and 35 m in the harbor, coastal and deep waters locations respectively. By increasing the transmitter power to 50 W, the operating range of the communication link could be increased up to 53 m in deep water locations in the Bay of Bengal.

Characterization of Elastic, Dielectric and Piezoelectric Properties of piezoelectric Materials

  • Cao, Wenwu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.13-22
    • /
    • 1999
  • Both the resonance and ultrasonic techniques are standard methods far characterizing the physical properties of piezoelectric materials. However, we found that each technique can only offer a few reliable measurements while the rest often have errors or impossible to implement because of the sample requirements. This paper show that one can use the combination of both techniques to achieve much better accuracy and be able to get the complete set of elastic, dielectric and piezoelectric coefficients using fewer samples. Using an ultrasonic spectroscopy we have also measure the dispersion of the ultrasonic velocity and the attenuation up to 65 MHz. Pb(Zr,Ti)O$_3$[PZT] ceramics were used as examples fur both studies.

  • PDF

A Finite Element Investigation of the Permittivity of Particulates (유전체 상수의 유한요소 시뮬레이션)

  • Braunstein, Jeffrey;Kwak, Yong-Soo;Kim, Hyeong-Seok;Park, Jun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2297-2299
    • /
    • 2005
  • In this paper, a finite element (FEM) investigation of composite materials is studied. A pemittivity profile of the material is implemented to correspond to the Packing fraction of the physical composite. Curve fitting is applied to the standing wave pattern to determine the effective attenuation coefficient and propagation constant in the composite. The complex permittivity as a function of packing density is then determined. A comparison between the two dimensional and three dimensional measurement simulations is presented. An adaptive scheme is implemented to improve resolution of the finite element particulates.

  • PDF

A Study on the Partial Discharge Wave Propagation along Stator Winding (회전기 권선의 펄스 전송특성 연구)

  • Kang, Dong-Sik;Sim, Woo-Yong;Hwang, Don-Ha;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

Assessment of Materials Degradation in a Hydrogen Environment (수소환경에서의 재료 열화도 평가)

  • Won, Sun-Ho;Hyeon, Yang-Gi;Lee, Jong-O;Lee, Jae-Do;Jo, Gyeong-Sik
    • 연구논문집
    • /
    • s.31
    • /
    • pp.149-156
    • /
    • 2001
  • Hydrogen damage affects carbon steel tubes in many fossil-fuel-fired boilers, often causing large tube ruptures that necessitate an immediate shutdown. Therefore, equipment handling high-temperature, high-pressure hydrogen must undergo careful periodic inspection because of its susceptibility to hydrogen attack. This paper describes the application of an ultrasonic technique for detecting the presence of hydrogen damage in utility boiler tubes. The accuracy of the technique has been shown in laboratory tests. However, it is difficult to evaluate hydrogen attack quantitatively by this technique, because ultrasonic wave is influenced by the test conditions and the material itself.

  • PDF