• Title/Summary/Keyword: attenuation measurement

Search Result 390, Processing Time 0.03 seconds

Study on enhancing the ultrasonic image for bone densitometry (골밀도 측정을 위한 초음파 영상 개선에 관한 연구)

  • Shin, Jung-Sik;Ahn, Jung-Hwan;Kim, Hyung-Joon;Kim, Hwa-Young;Han, Seung-Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.182-191
    • /
    • 2005
  • It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.

A Characteristics of Impedance Propagation by the Unsteady Flow in a Hydraulic Pipeline (유압관로의 비정상유동에 따른 임피던스 전달특성)

  • Mo Yang-Woo;Yoo Young-Tae;Na Gee-Dae;Kim Ji-Hwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.48-55
    • /
    • 2004
  • Design for quite operation of fluid power system requires the understanding of noise and vibration characteristics of the system. This paper presents a dynamic response of design of hydraulic circuit. Experimental investigations on the attenuation of pressure ripple in automotive power steering hydraulic pipe line is examined. Also, a mathematical model of hydraulic pipe is p개posed to support a design of the hydraulic circuit. and the impedance characteristics of pressure ripple is analyzed. It is experimentally shown that power steering hydraulic pipe attenuates pressure ripple with high frequency.

Acoustic and Flow-filed Analysis of Suction Muffler in Compressor (압축기용 흡입머플러의 음향 및 유동해석)

  • 주재만;이학준;오상경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1162-1167
    • /
    • 2001
  • Suction valve fluttering is generated by reciprocating motions of the piston inhaling and discharging process of gas in the hermetic compressor. A reactive type suction muffler, which produces high pressure-drop because of its complicated flow path, controls the impulsive noise radiated from the flutter of suction valve. The high-pressure drop in the muffler increases the transmission loss, but reduces the EER(Energy Efficiency Ratio) of the compressor. We consider how to design the high acoustic attenuation and low pressure-drop performance to take account of the acoustic and flow performances of the suction muffler. In this study, we identified the suction noise source of compressor from the measurement of the acoustic pulsation and flutter of suction valve. We analyzed the acoustic characteristics of muffler using the finite element method, and compared the experimental and analytical characteristics of flow path of suction muffler. Theoretical predictions and experimental results are compared from the viewpoint of the acoustic performance and energy efficiency of the compressor.

  • PDF

Design of reflection type low phase shift attenuator (반사형 저위상 변화 감쇠기의 설계)

  • 강민수;강원태;장익수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.9
    • /
    • pp.1-6
    • /
    • 1997
  • A transmission type phase shift attenuator has a poor reflection characteristics at an output port. And that is controlled by the current, its dynamic rnage decreases due to the current limitation. In this paper, to avoid such disadvantages, a reflection type low phase shift attenuator has been designed and measured. As a result, at a center frequency (1855MHz), the sreflection type low pahse shift attenuator has an attenuation of 30dB, within the limit of 3 phase shift and less than -17dB reflection characteristics at both input and output ports. And it demonstrates the peformance of the reflection type low phase shift attenuator is better than the transmission type phase shift attenuator with the same measurement specifications.

  • PDF

The Evaluation of Work Noise in Tunnel under Construction (터널 내 작업소음 평가)

  • Yun, Chang-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.3
    • /
    • pp.103-107
    • /
    • 2014
  • To assess a various of workplace noise environment in the tunnel construction site, the measurement is performed while tunnel constructing work. This study focuses on the sound attenuation according to the sound frequency characteristics and the distance from various works in the tunnel. Also, the noise distribution while blasting work is measured according to distance in this study. In addition, the boring processing, muck treatment, and tunnel lining by distance are measured for the noise distributions.

Development of Self-compensated Technique for Evaluation of Surface-breaking Crack by Using Laser Based Ultrasound

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.3
    • /
    • pp.215-221
    • /
    • 2005
  • It is required to evaluate nondestructively depth of surface-breaking cracks in structures. In this paper, the self-compensated technique by laser-based ultrasound is used to measure the depth of surface-breaking defect. Optical generation of ultrasound produces a well defined pulse with reliable frequency content. It is broad banded and suitable for measurement of attenuation and scattering over a wide frequency range. The self-calibrated signal transmission data of surface wave shows good sensitivity as a practical tool far assessment of surface-breaking defect depth. It is suggested that the relationship between the signal transmission and crack depth can be used to predict the surface-breaking crack depths in structures.

A novel transversal filter with improved spurious characteristics (스퓨리어스 특성이 개선된 새로운 구조의 트랜스버살 필터)

  • Jee, Ki-Mann
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.611-621
    • /
    • 2003
  • A spurious-suppressed transversal filter using the multiple-coupled line is proposed. The frequency characteristics of the multiple-coupled line are analyzed in detail. In order to compare the performances, the novel spurious-suppressed transversal filter using triple-coupled half-wavelength directional couplers is designed at 5 GHz. The spurious-suppression characteristics of the proposed transversal filter are verified by the full wave analysis and the measurement. The spurious response of the fabricated filter is effectively suppressed up to 13 GHz and the large attenuation is attained in the stopband.

  • PDF

Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE (가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF

The Effect of Insertion Loss on the Element of Exhaust Muffler (배기 소음기 구조가 삽입손실에 미치는 영향)

  • 강동림;김영호;전현부기;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.42-51
    • /
    • 2000
  • The performances of the simple expansion, perforated tube, and conical-connector type as an exhaust muffler are shown in this study. Applying a model in which the method of four-pole parameter is used makes theoretical estimation of the insertion loss. Experiment is performed for the measurement of the insertion loss under four cases according to the variation of the tail pipe length. By comparing the theoretical prediction with the experimental results, the validity of the modeling using the method of four-pole parameter is verified. The personal computer simulation programs for the above mentioned theory on the muffler design have been developed and exhaust sound level measurements have been carried out for simple expansion muffler, conical-connector muffler, perforated tube mufflers and the combined type of conical-connector and simple expansion muffler. The measured results for attenuation characteristics of noise for each muffler are compared with the computed theoretical results to verity the confidence and applicable limits of the theoretical equation derived.

  • PDF

An Experimental Study on the Light Transmission Characteristics with Oil Contamination (윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • Changes in light transmission characteristics caused by various types of oil contaminations were experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon duct, two kinds of solutions and grease were used for the test contaminants in this work. Light intensity of the transmitted light was measured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and poly-meric fibers in terms of the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change in lubricating oils.