• 제목/요약/키워드: attenuation correction

검색결과 184건 처리시간 0.03초

VERTICAL OZONE DENSITY PROFILING BY UV RADIOMETER ONBOARD KSR-III

  • Hwang Seung-Hyun;Kim Jhoon;Lee Soo-Jin;Kim Kwang-Soo;Ji Ki-Man;Shin Myung-Ho;Chung Eui-Seung
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.372-375
    • /
    • 2004
  • The UV radiometer payload was launched successfully from the west coastal area of Korea Peninsula aboard KSR-III on 28, Nov 2002. KSR-III was the Korean third generation sounding rocket and was developed as intermediate step to larger space launch vehicle with liquid propulsion engine system. UV radiometer onboard KSR-III consists of UV and visible band optical phototubes to measure the direct solar attenuation during rocket ascending phase. For UV detection, 4 channel of sensors were installed in electronics payload section and each channel has 255, 290, 310nm center wavelengths, respectively. 450nm channel was used as reference for correction of the rocket attitude during the flight. Transmission characteristics of all channels were calibrated precisely prior to the flight test at the Optical Lab. in KARI (Korea Aerospace Research Institute). During a total of 231s flight time, the onboard data telemetered to the ground station in real time. The ozone column density was calculated by this telemetry raw data. From the calculated column density, the vertical ozone profile over Korea Peninsula was obtained with sensor calibration data. Our results had reasonable agreements compared with various observations such as ground Umkhr measurement at Yonsei site, ozonesonde at Pohang site, and satellite measurements of HALOE and POAM. The sensitivity analysis of retrieval algorithm for parameters was performed and it was provided that significant error sources of the retrieval algorithm.

  • PDF

BF 컨버터의 고조파 감쇠에 관한 연구 (A study on the haromnic attenuation of the BF Converter)

  • 최태섭;안인수;임승하;사공석진
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.8-15
    • /
    • 2000
  • 본 논문에서는 F 컨버터의 능동형 PFC 시스템을 구성하고, 진력 변환시 입력 전류를 전원 전압과 동장연 정현파로 제이하는 동시에 출력 전압에 포함되는 고조파 등의 잡음을 제거하고 직류 출력 전압을 제어하기 위한 PWM-PFM 제어 기법을 제시하였다. 부하단에서 필요한 전압과 높은 전력 효율을 얻기 위하여 인버터 단계애서 전류 성형 제어를 실행한 후, 순방­향(forward) 컨버터에 의해 다시 직류 전압으로 변환시켜 부하단으로 출력한다. 입력 전압이 30[V]이교 승압 (boost) 인덕터가 1.1[mH]일 때 정격 출력은 전압 50[V], 전류1[A], 듀티비 0.5 이상으로 하여 부하 처항에 따른 전압 변화를 PWM-PFM 제어 기법을 이용하며 제어하였고, 전류 성형 기법을 이용하여 0.93획 역률로 고조파를 감쇠 및 개선하였다.

  • PDF

저속 PLC 모뎀에서의 Chirp 신호 방식과 시스템 구현에 관한 연구 (A study for chirp signal method & system implementation in the PLC modem with low speed)

  • 정영화;이상건
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.37-45
    • /
    • 2004
  • 제어 목적으로 주로 사용되는 기존의 60bps 급 저속 전력선 통신 모뎀에 적용된 대표적인 통신 방식은 단일 캐리어 방식이다. 단일 캐리어 방식은 전력선 통신 채널 환경에 매우 민감하다. 특히 채널의 notch 필터 특성에 따른 송신 신호의 극심한 감쇄는 통신 에러의 주 원인이 된다. 국내 전력선 채널 환경은 이러한 특징이 매우 강하다. 본 논문에서는 notch 특성 및 잡음 특성에 강한 Chirp 신호 방식을 이용한 저속 전력선 통신 시스템을 구현하였다. 본 연구에서는 1 비트에 대해 1ms 내에 100${\mu}s$의 1 Unit 심볼 Chirp 신호 10개를 전소하는 방식을 제안하였다. 또한 오류 정정을 위한 Convolution 부호와 충돌 감지 및 에러 검출을 위한 맨체스터 부호를 적용하였으며, 수신부에서 신호 검출을 위해 비트 상관기를 이용한 방식을 사용하였다. 60bps급 저속 전력선 통신 시스템을 구현하여 실험한 결과 Chirp 방식의 통신 방식이 단일 캐리어 방식에 비해 뛰어난 성능을 가짐을 확인하였다.

  • PDF

The structural changes of pharyngeal airway contributing to snoring after orthognathic surgery in skeletal class III patients

  • Park, Jung-Eun;Bae, Seon-Hye;Choi, Young-Jun;Choi, Won-Cheul;Kim, Hye-Won;Lee, Ui-Lyong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.22.1-22.9
    • /
    • 2017
  • Background: Two-jaw surgery including mandibular and maxillary backward movement procedures are commonly performed to correct class III malocclusion. Bimaxillary surgery can reposition the maxillofacial bone together with soft tissue, such as the soft palate and the tongue base. We analyzed changes of pharyngeal airway narrowing to ascertain clinical correlations with the prevalence of snoring after two-jaw surgery. Methods: A prospective clinical study was designed including a survey on snoring and three-dimensional (3D) computed tomography (CT) in class III malocclusion subjects before and after bimaxillary surgery. We conducted an analysis on changes of the posterior pharyngeal space find out clinical correlations with the prevalence of snoring. Results: Among 67 subjects, 12 subjects complained about snoring 5 weeks after the surgical correction, and examining the 12 subjects after 6 months, 6 patients complained about the snoring. The current findings demonstrated the attenuation of the largest transverse width (LTW), anteroposterior length (APL), and cross-sectional area (CSA) following bimaxillary surgery given to class III malocclusion patients, particularly at the retropalatal level. The average distance of maxillary posterior movements were measured to be relatively higher (horizontal distance 3.9 mm, vertical distance 2.6 mm) in case of new snorers. Conclusions: This study found that bimaxillary surgery could lead to the narrowing of upper airway at the retropalatal or retroglossal level as well as triggering snoring in subjects with class III malocclusion. Based on the current clinical findings, we also found that upper airway narrowing at retropalatal level may contribute to increasing the probability of snoring and that polysonography may need to be performed before orthognathic surgery in subjects with class III malocclusion.

X밴드 선박용 레이더를 이용한 강우 추정 (Rainfall Estimation by X-band Marine Radar)

  • 김광호;권병혁;김민성;김박사;윤홍주
    • 한국전자통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.695-704
    • /
    • 2018
  • X밴드 선박용 레이더를 이용하여 개발한 강우 추정 기술로 강우 사례를 검증하였다. 디지털 신호 변환기를 사용하여 선박용 레이더로부터 수신된 신호를 디지털 반사 정보로 변환하였다. 반사도 정보에서 지형클러터 신호를 제거하고, 빔 감쇠와 빔 부피의 변화에 의해 발생하는 오류를 보정 처리하였다. 처리된 반사 정보는 우량계 강우량과 선형적인 관계를 보였다. 레이더 신호를 직교좌표계로 변환하여 정량적 강우를 추정하였다. 자동기상관측소 세 지점에서 $5mm\;hr^{-1}$ 이상의 강우가 기록된 사례에서 선박용 레이더의 강우 분포는 기상청 운용 기상 레이더의 결과와 일치하였다.

핵의학 융합영상의 표준섭취계수 차이에 관한 연구 (Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

Comparison of GAN Deep Learning Methods for Underwater Optical Image Enhancement

  • Kim, Hong-Gi;Seo, Jung-Min;Kim, Soo Mee
    • 한국해양공학회지
    • /
    • 제36권1호
    • /
    • pp.32-40
    • /
    • 2022
  • Underwater optical images face various limitations that degrade the image quality compared with optical images taken in our atmosphere. Attenuation according to the wavelength of light and reflection by very small floating objects cause low contrast, blurry clarity, and color degradation in underwater images. We constructed an image data of the Korean sea and enhanced it by learning the characteristics of underwater images using the deep learning techniques of CycleGAN (cycle-consistent adversarial network), UGAN (underwater GAN), FUnIE-GAN (fast underwater image enhancement GAN). In addition, the underwater optical image was enhanced using the image processing technique of Image Fusion. For a quantitative performance comparison, UIQM (underwater image quality measure), which evaluates the performance of the enhancement in terms of colorfulness, sharpness, and contrast, and UCIQE (underwater color image quality evaluation), which evaluates the performance in terms of chroma, luminance, and saturation were calculated. For 100 underwater images taken in Korean seas, the average UIQMs of CycleGAN, UGAN, and FUnIE-GAN were 3.91, 3.42, and 2.66, respectively, and the average UCIQEs were measured to be 29.9, 26.77, and 22.88, respectively. The average UIQM and UCIQE of Image Fusion were 3.63 and 23.59, respectively. CycleGAN and UGAN qualitatively and quantitatively improved the image quality in various underwater environments, and FUnIE-GAN had performance differences depending on the underwater environment. Image Fusion showed good performance in terms of color correction and sharpness enhancement. It is expected that this method can be used for monitoring underwater works and the autonomous operation of unmanned vehicles by improving the visibility of underwater situations more accurately.

PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화 (The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters)

  • 신규설;동경래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.373-379
    • /
    • 2007
  • 목 적: PET이 PET-CT로 오면서 가장 큰 차이를 보이고 있는 점은 감쇄보정을 위한 투과영상의 차이이다. PET CT에서는 CT영상을 감쇄보정에 이용하고 있으며, CT 요인들이 PET 영상의 감쇄보정시 영향을 줄 수 있을 것으로 예상된다. 본 연구에서는 CT의 관전압과 관전류의 변화에 따라 PET의 정량성 평가로 이용되는 SUV(standard uptake value)의 값이 변화가 있는지를 평가하였다. 재료 및 방법: Data spectrum's lung phantom을 이용하여 $^{18}F$-FDG 1.909 mCi(팬텀 1)와 $913\;{\mu}Ci$(팬텀 2) 각각 물과 함께 넣고 흔들어 균일한 상태를 만든 후, 관전압을 80 kVp, 100 kVp, 120 kVp, 140 kVp까지, 관전압변화 당 관전류 10 mA에서 100 mA까지 각각 10 mA씩 변화를 주어 CT 영상을 얻었다. PET 영상을 각각의 CT영상을 이용하여 재구성 하였으며, 같은 부위에서의 SUV값을 구하여 그 차이를 비교하였다. 결 과: 팬텀 1의 SUV는 관전압 80, 100, 120, 140 kVp CT영상을 이용했을 때, 각각 $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$, $12.27{\pm}0.009$로 나타났다. 팬텀 2에서는 관접압을 달리 하였을 때 각각 $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$, $4.52{\pm}0.005$의 SUV를 보였다. 이들은 모두 관전압을 달리 하였을 때 통계적으로 유의한 SUV 변화를 보이지 않았다. 또한 관전류의 변화에서도 팬텀 1, 2 모두에서 유의한 SUV 차이는 나타나지 않았다. 결 론: 본 연구 결과 CT 요인의 변화가 PET 영상에서 SUV에 유의한 영향을 미치지 않았다. 따라서 PET CT 이용 시 SUV에 유의한 영향 없이 임상적 조건에 맞게 CT 요인들을 변화 시키는 응용이 가능할 것으로 생각된다.

  • PDF

SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰 (Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality)

  • 윤석환;이성환;조성욱;김진의
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.33-38
    • /
    • 2014
  • SPECT의 기능적인 영상과 CT의 해부학적 영상을 융합하여 영상 진단의 시너지 효과를 창출하는 SPECT/CT는 부가적인 CT의 사용으로 환자의 피폭선량을 증가시킨다. SPECT/CT를 사용함으로서 불가피한 피폭선량에 대한 선량감소 효과를 위해 CT의 방사선 노출 시 선량이 환자의 크기와 모양에 따라 자동조절 되는 CT장비의 자동노출제어(Automatic exposure control, AEC)시스템을 SPECT/CT에 적용함으로써 피폭선량의 감소효과와 영상의 질의 변화를 비교 및 평가하고자 하였다. 실험에 사용된 SPECT/CT는 GE사의 Discovery 670이며, AEC 기법으로는 Smart mA를 선원은 $^{99m}Tc$을 사용하였다. CT선량 변화에 따른 SPECT영상과 CT영상의 질을 비교하기 위해 CT의 조건을 첫 번째 관전압 80, 100, 120, 140 kVp, 관전류 10, 30, 50, 100, 150, 200, 250 mA, 두 번째 AEC기법은 (10-250 mA)로 설정하여 실험하였으며, SPECT영상의 resolution과 contrast를 평가하기 위해 triple line phantom과 Flangeless Esser PET phantom을 사용하였으며, CT영상과 선량을 평가하기 위해서 anthropomorphic chest phantom을 이용하였다. Torso protocol (120 kVp, 150 mA)을 적용하였으며 AEC기법(120 kVp, 10-200 mA)으로 촬영하여 noise와 uniformity를 측정하였으며, CTDI (mGy), DLP (mGycm)값을 구하였다. 관전압, 관전류의 변화와 AEC 적용에 대한 감쇠보정 한 SPECT영상에서의 Resolution은 FWHM [mm] left 3.48 mm, center 3.65 mm, right 3.60 mm로 일정한 값을 보였다. Contrast의 결과 값은 cold spot에 대한 감쇠물질 정도에 따른 공기, 물에 대해서는 큰 차이를 나타내지 않았으며, 뼈에 대해서는 관전압이 증가할수록 감소하는 값을 보였다. Hot spot에 대해서는 관전압과 관전류의 변화 그리고 AEC를 적용 시 큰 차이를 보이지 않았다. CT영상에서의 noise값을 각각 비교한 결과 15.4, 18.5으로 AEC적용 시 noise 값은 증가하였지만 noise값의 coefficient variation (CV)값은 각각 33.8, 24.9으로 AEC 사용 시 노이즈 값의 변동이 작아 uniformity한 영상을 얻을 수 있었다. 선량평가를 위한 비교에서 DLP[mGy-cm]값은 426.78, AEC 적용 시 352.09의 값을 보여 AEC적용 시 피폭선량이 약 18% 감소함을 알 수 있었다. 본 실험을 통하여, SPECT/CT 영상에서 CT선량변화에 따른 SPECT 영상의 감쇠보정은 차이가 없음을 확인 할 수 있었으며, CT선량의 증가는 CT영상의 질은 향상되지만, 피폭선량이 증가하므로 피폭선량을 줄이기 위해 AEC기법을 적용하여 동일한 감쇠 보정된 SPECT영상과 noise가 균일한 CT영상을 획득할 수 있으며 피폭선량이 감소할 수 있을 것으로 기대된다.

  • PDF

FDG-PET을 이용한 악성과 양성 연부조직 병변의 감별: 반정량적 지표간의 비교 (The Differentiation of Benign from Maligant Soft Tissue Lesions using FDG-PET: Comparison between Semi-quantitative Indices)

  • 최준영;이경한;최용;최연성;김상은;서재곤;김병태
    • 대한핵의학회지
    • /
    • 제31권1호
    • /
    • pp.90-101
    • /
    • 1997
  • FDG-PET의 반정량적인 당대사지표인 pSUV, aSUV, $TBR_{51}$$TBR_{area}$는 비관혈적으로 악성과 양성 연부조직 병변을 감별하는 데 모두 높은 정확도를 나타내었다. FDG-PET은 연부조직 종양의 평가에서 MRI와 상호보완적인 역할을 할 수 있을 것이다. 또한 FDG-PET은 악성 연부조직 종양환자들의 전이의 발견과 치료 후 추적관찰에도 도움이 될 것으로 생각되며 이에 관한 연구가 계속되어야 할 것이다.

  • PDF