• Title/Summary/Keyword: attachment level

Search Result 500, Processing Time 0.031 seconds

Analysis of functional load on the dentated skull with unilateral molar loss during simulated bilateral clenching clenching (이악물기 치아접촉시 편측 구치 상실을 지닌 두개골의 부하분석)

  • Jeong, SeogJo;Jeong, SeungMi;Kang, DongWan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.245-256
    • /
    • 2001
  • The purpose of this study is to analyze the mechanical stress and displacement on the jaws during the simulated bilateral clenching task on the three-dimensional finite element model of the dentated skull with unilateral molar loss. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 2.0mm intervals. The fully assembled finite element model consists of the articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The FE model was used to simulate the bilateral clenching in intercuspal position. The loading condition was the force of the masseter muscle exerted on the mandible as reported by Korioth et al. degrees of freedom of the zygomatic region where the masseter muscle is attached were fixed as restraints. In order to reflect the actual action of the muscles force, the displacement of the region was attached where the muscle is connected to the temporal bone and restraint conditions were given values identical to values at the attachment region of the masticatory muscle but with the opposite direction of the reaction from when the muscle force is acted on the mandible. Although the mandible generally has higher displacement and von Mises stress than the maxilla, its mandibular corpus on the molar-loss side has a higher stress and displacement than the molar-presence side. Because the displacement and von Mises Stress was the highest on the lateral surface of mandibular corpus with molar loss, the stress level of the condyle on the molar-loss side is greater than that of the molar-presence side, which in turn caused the symphysis of the mandible to bend. In conclusion, the unilateral posterior bite collapse with molar loss under para-functional activities such as bruxism and clenching can affect the stress concentration on the condyle and mandibular corpus. It is therefore necessary to consider the biomechanical function of dento-skeleton under masticatory force while designing the occlusal scheme of restoration on alveolar bone with the posterior collapse.

  • PDF

Response of osteoblast-like cells cultured on zirconia to bone morphogenetic protein-2

  • Han, Seung-Hee;Kim, Kyoung-Hwa;Han, Jung-Seok;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.227-233
    • /
    • 2011
  • Purpose: The aim of this study was to compare osteoblast behavior on zirconia and titanium under conditions cultured with bone morphogenetic protein-2. Methods: MC3T3-E1 cells were cultured on sandblasted zirconia and sandblasted/etched titanium discs. At 24 hours after seeding MC3T3-E1, the demineralized bone matrix (DBM) gel alone and the DBM gel with bone morphogenetic protein-2 (BMP-2) were added to the culture medium. The surface topography was examined by confocal laser scanning microscopy. Cellular proliferation was measured at 1, 4, and 7 days after gel loading. Alkaline phosphatase activity was measured at 7 days after gel loading. The mRNA expression of ALPase, bone sialoprotein, type I collagen, runt-related transcription factor 2 (Runx-2), osteocalcin, and osterix were evaluated by real-time polymerase chain reaction at 4 days and 7 days. Results: At 1, 4, and 7 days after loading the DBM gel alone and the DBM gel with BMP-2, cellular proliferation on the zirconia and titanium discs was similar and that of the groups cultured with the DBM gel alone and the DBM gel with BMP-2 was not significantly different, except for titanium with BMP-2 gel. ALPase activity was higher in the cells cultured with BMP-2 than in the other groups, but there was no difference between the zirconia and titanium. In ALPase, bone sialoprotein, osteocalcin, Runx-2 and osterix gene expression, that of cells on zirconia or titanium with BMP-2 gel was much more highly increased than titanium without gel at day 7. The gene expression level of cells cultured on zirconia with BMP-2 was higher than that on titanium with BMP-2 at day 7. Conclusions: The data in this study demonstrate that the osteoblastic cell attachment and proliferation of zirconia were comparable to those of titanium. With the stimulation of BMP-2, zirconia has a more pronounced effect on the proliferation and differentiation of the osteoblastic cells compared with titanium.

The effects of ozone therapy as an adjunct to the surgical treatment of peri-implantitis

  • Isler, Sila Cagri;Unsal, Berrin;Soysal, Fatma;Ozcan, Gonen;Peker, Elif;Karaca, Inci Rana
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.136-151
    • /
    • 2018
  • Purpose: The decontamination procedure is a challenging aspect of surgical regenerative therapy (SRT) of peri-implantitis that affects its success. The purpose of the present study was to determine the impact of additional topical gaseous ozone therapy on the decontamination of implant surfaces in SRT of peri-implantitis. Methods: A total of 41 patients (22 males, 19 females; mean age, $53.55{\pm}8.98years$) with moderate or advanced peri-implantitis were randomly allocated to the test group (ozone group) with the use of sterile saline with additional ozone therapy or the control group with sterile saline alone for decontamination of the implant surfaces in SRT of peri-implantitis. Clinical and radiographic outcomes were evaluated over a period of 12 months. Results: At the 12-month follow-up, the plaque and gingival index values were significantly better in the ozone group (P<0.05). Probing depth decreased from $6.27{\pm}1.42mm$ and $5.73{\pm}1.11mm$ at baseline to $2.75{\pm}0.7mm$ and $3.34{\pm}0.85mm$ at the end of the 12-month observation period in the ozone and control groups, respectively. Similarly, the clinical attachment level values changed from $6.39{\pm}1.23mm$ and $5.89{\pm}1.23mm$ at baseline to $3.23{\pm}1.24mm$ and $3.91{\pm}1.36mm$ at the 12-month follow-up in the ozone and control groups, respectively. According to the radiographic evidence, the defect fill between baseline and 12 months postoperatively was $2.32{\pm}1.28mm$ in the ozone group and $1.17{\pm}0.77mm$ in the control group, which was a statistically significant between-group difference (P<0.05). Conclusions: Implant surface decontamination with the additional use of ozone therapy in SRT of peri-implantitis showed clinically and radiographically significant. Trial registry at ClinicalTrials.gov, NCT03018795.

Design and Implementation of 8b/10b Encoder/Decoder for Serial ATA (직렬 ATA용 8b/10b 인코더와 디코더 설계 및 구현)

  • Heo Jung-Hwa;Park Nho-Kyung;Park Sang-Bong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1A
    • /
    • pp.93-98
    • /
    • 2004
  • Serial ATA interface Is inexpensive comparatively and performance is superior. So it is suitable technology in demand that now require data transmission and throughput of high speed. This paper describes a design and implementation of Serial ATA Link layer about error detection and 8b/10b encoder/decoder for DC balance in frequency 150MHz. The 8b/10b Encoder is partitioned into a 5b/6b plus a 3b/4b coder. The logical model of the block is described by using Verilog HDL at register transistor level and the verified HDL is synthesized using standard cell libraries. And it is fabricated with $0.35{\mu}m$ Standard CMOS Cell library and the chip size is about $1500{\mu}m\;*\;1500{\mu}m$. The function of this chip has been verified and tested using testboard with FPGA equipment and IDEC ATS2 test equipment. It is used to frequency of 100MHz in verification processes and supply voltage 3.3V. The result of testing is well on the system clock 100MHz. The designed and verified each blocks may be used IP in the field of high speed serial data communication.

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

Early Growth Changes in Juvenile Abalone Haliotis discus discus Produced by Irradiation with Low-dose 60Co Gamma Rays (저선량 60Co감마선 조사 후 생산된 둥근전복(Haliotis discus discus)치패의 초기성장 변화에 관한 연구)

  • Jwa, Min Seok;Yeo, In-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.2
    • /
    • pp.193-199
    • /
    • 2015
  • We observed that the growth and physiological change in Haliotis discus discus by low-dose irradiation with gamma ray.Irradiation with gamma ray was undertaken by using the low-level irradiation facility ($^{60}CO$) in cooperation with the Institute of Nuclear Science and Technology at Jeju National University. The parent abalones were attached one by one and then fixed by using the rubber band to the front side of the fabricated case for irradiation with gamma ray. The experimental plots of irradiation with gamma ray were set as 10, 15, 20 and 25 Gy and the 25 female abalones and 10 male abalones were utilized for each experimental plot. The sperms and eggs were fertilized by setting an interval for each dose to prevent mixing with other experimental plots when fertilizing the sperms and eggs for each dose of irradiation with gamma ray. As for the fertility, it was confirmed to be 85% the control and 10 Gy groups, whereas it was found to be 80%, 65% and 50% in the 15 Gy, 20 Gy and 25 Gy groups, respectively. As a conclusion, the hatching rate and attachment rate were higher at 10 and 15 Gy than the other experimental plots, and the growth rate was higher at 20 Gy than the other experimental plots. Also the changes in lysozyme activity in accordance with the stress of water temperature were found to have a significant increase in the other experimental plots as compared with the control plot at the end of 0 h. The changes in lysozyme activity have remained constant in all the experimental plots at the end of 12 h. These results allowed us to confirm that lysozyme was undertaking the biodefense action by reacting sensitively to the stress of water temperature in the control experimental plot. As for the other experimental plots, they are believed to avoid the biodefense mechanism due to the high degree of anti-parasite mechanism and anti-viral mechanism. Thus, it is believed that it would be imperative to conduct development and research on breeds that were potent for environmental tolerance by applying the method of irradiation with gamma ray to other marine animals and plants.

A study in Mack-Gyung(脈經) on taking pulse of relative weight to five Viscera attachment system in Nan-Gyung(難經) (난경(難經)에서 안맥(按脈)의 경중(輕重)에 따른 오장배속방법(五臟配屬方法)에 대(對)한 맥경(脈經)과의 비교(比較) 연구(硏究))

  • Nam, Doo-Yeul;Kim, Tae-Hee
    • The Journal of Internal Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.61-69
    • /
    • 1992
  • In Nan-Gyung, showed that could know the lung condition taking pulse with the weight of three beans, the heart condition taking pulse with the weight of six beans, the spleen condition taking pulse with the weight of nine beans, the liver condition taking pulse with the weight of twelve beans, the kidney condition pressing to bone(骨). This theory is first suggested in Nan-Gyung(難經). In those case, the weight of three, six, nine, twelve beans and pressing to bone don't mean not the real weight but the relative weight(輕重) of taking pulse(按脈). In other words, those represent Boo Jung Chin(浮中沈), which are the conception of the upper, the meddle, the lower part(上中下). So, we could take pulse of the heart and the lung condition in Boo(浮), the spleen condition in Jung(中), and the liver and the kidney condition in Chim(沈). The heart and the lung pulse showed in the Boo(float level) must be seen with Boo-Mack(부맥 : float pulse), the liver and the kidney pulse showed in Chim (sinklevel) must be seen also with Chin-Mack(沈脈 : sink pulse). The result of the method of taking pulse of viscera with relative weight focused on the as pect of mornal pulse(平脈) and disease pulse(病脈) of five viscera in Mack-Gyung publeshed later than Nan-Gyung and special works which made a comprehensive survey the result is as follow. 1. In normal pulse of five viscera, the heart and the lunk pulse were shown with Boo-Mack(浮脈:float pulse) as the central figure, the liver's and the kidney's pulse were shown centering around Chim-Mack(沈脈: sink pulse) and the spleen's pulse was shown with Wan-Mack(緩脈) which is vital force of stomach(胃氣) and seen in only middle part. 2. In disease pulse of five viscera, frequently, the heart and the lung pulse was shown as Chim-Mack(sink pulse), the liver and the kidney pulse was seen as Boo-Mack (float pulse). 3. In the case of normal pulse. the method of taking pulse with relative weight in Nan-Gyung agree with the normal pulse of five viscera in Mack-Gyung. But in the case of disease pulse, they didn't correspond with the other. 4. So the method of taking pulse with relative weight in Nan-Gyung is not the exam pulse which ca be used in the clinical diagnosis but one of the feeling pulse way to bring in the conception of location of the visceras. 5. From now on, the method of taking pulse rdlated to relative weight need to be looked into minutely compared with later physician's theory than Mack-Gyung.

  • PDF

Discussion about the Self Disposal Guideline of Medical Radioactive Waste (의료용 방사성폐기물 자체처분 가이드라인에 관한 고찰)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Lee, In-Won;Park, Young-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.13-27
    • /
    • 2017
  • Purpose In the procedure of domestic medical radioactive self-disposal, there are many requests of supplementation and difficulties on the screening process. In this regard, presentation of basic guideline will improve the work processing efficiency of medical institution radioactive waste. From 2015 to 2016, We reviewed and compared a supplementary requests of domestic fifteen medical institution radioactive self-disposal Plan & Procedure manual. In connection with this, we derive the details of the radioactive waste document based on the relative regulation of nuclear safety Act. The representative supplementary requests of Korea Institute of Nuclear Safety are disposal method of non-flammability radioactive waste, storage method of scheduled self-disposal waste, the legitimacy of self-disposal and pre-treatment of self-disposal, reference radioactivity of disused filter and output of storage period, attachment the evidential matter of measurement efficiency when using a gamma counter. Through establishing a medical radioactive waste guideline, we can clearly suggest a classification standard of radioactive nuclide and the type of occurrence. As a result, we can confirm the reduction of examination processing period while preparing a self-disposal document and there is no spending expenses for business agency. Also, the storage efficiency of facility will better and reduce the economic expenses. On the basis of this guideline, we will expect a contribution to the improvement of work efficiency for officials who has a working-level difficulty of radioactive waste self-disposal.

  • PDF

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

Effectiveness of alendronate as an adjunct to scaling and root planing in the treatment of periodontitis: a meta-analysis of randomized controlled clinical trials

  • Chen, Jin;Chen, Qian;Hu, Bo;Wang, Yunji;Song, Jinlin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.382-395
    • /
    • 2016
  • Purpose: Alendronate has been proposed as a local and systemic drug treatment used as an adjunct to scaling and root planing (SRP) for the treatment of periodontitis. However, its effectiveness has yet to be conclusively established. The purpose of the present meta-analysis was to assess the effectiveness of SRP with alendronate on periodontitis compared to SRP alone. Methods: Five electronic databases were used by 2 independent reviewers to identify relevant articles from the earliest records up to September 2016. Randomized controlled trials (RCTs) comparing SRP with alendronate to SRP with placebo in the treatment of periodontitis were included. The outcome measures were changes in bone defect fill, probing depth (PD), and clinical attachment level (CAL) from baseline to 6 months. A fixed-effect or random-effect model was used to pool the extracted data, as appropriate. Mean differences (MDs) with 95% confidence intervals (CIs) were calculated. Heterogeneity was assessed using the Cochrane ${\chi}^2$ and $I^2$ tests. Results: After the selection process, 8 articles were included in the meta-analysis. Compared with SRP alone, the adjunctive mean benefits of locally delivered alendronate were 38.25% for bone defect fill increase (95% CI=33.05%-43.45%; P<0.001; $I^2=94.0%$), 2.29 mm for PD reduction (95% CI=2.07-2.52 mm; P<0.001; $I^2=0.0%$) and 1.92 mm for CAL gain (95% CI=1.55-2.30 mm; P<0.001; $I^2=66.0%$). In addition, systemically administered alendronate with SRP significantly reduced PD by 0.36 mm (95% CI=0.18-0.55 mm; P<0.001; $I^2=0.0%$) and increased CAL by 0.39 mm (95% CI=0.11-0.68 mm; P=0.006; $I^2=6.0%$). Conclusions: The collective evidence regarding the adjunctive use of alendronate locally and systemically with SRP indicates that the combined treatment can improve the efficacy of non-surgical periodontal therapy on increasing CAL and bone defect fill and reducing PD. However, precautions must be exercised in interpreting these results, and multicenter studies evaluating this specific application should be carried out.