Stability limit state design of box sections supporting mining and process facilities

  • Bedair, Osama
    • Structural Engineering and Mechanics
    • /
    • v.39 no.5
    • /
    • pp.643-659
    • /
    • 2011
  • The design of box girders requires the determinations the buckling stress of the flange and the webs. Existing design equations available in codes of practice ignore the interactions between the box girder components. The paper illustrates the influence of the geometric interaction on the buckling stress of box girders. Generalized equations are first derived in terms of the web the flange geometric properties. Industrial examples are then presented showing the variation of the flange buckling stress for various stiffening configurations. The influence of the flange/web proportions on the buckling stress of box girder components is also highlighted. It is shown that buckling strength of the flange is largely affected by the restraints imposed by the webs or attached diaphragms. Graphs are presented showing various limiting states of box girders. These graphs are useful to use in practice in order to achieve economical and efficient design of box girders and rationally predict local buckling stress.

The research about being formed outside space around apartment house in Japan (일본의 공동주택 외부공간 형성에 관한 연구)

  • 김한수
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.173-183
    • /
    • 2001
  • The research was investigated and analysed to get basic data which was made outside environment at apartment house complex. The subject of research is housing complex in Japan. Result of research is as following. 1) The house environment is amenity, because they developed the space as green area and open space without developing outside space as a parking lot. 2) They have developed an apartment design variously. it has variety that the design of facets colors, roof forms, attached facilities etc. 3) Housing complex's center axis is needed to make a plan, that a pedestrian passage which is rich in green area is better than a road.

  • PDF

The Actual Conditions of Bathroom and their problems (아파트 욕실 공간의 사용실태와 문제점 검토)

  • HikyungLim
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1995.10a
    • /
    • pp.121-128
    • /
    • 1995
  • The object of this study is to analyze the actual use of and the problems of bathrooms in urban apartments which have two bathrooms. There are some problems with the present western style bathrooms which have three different facilities in the same room: a toilet, a bathtub, and a washstand. Twenty-five percent of the respondents use the bathtub as a water tank or a storage. A toil not combined with a bathtub as well as some dressing space are desired for the main bathroom. Many residents of young age satisfied with the bathroom attached to the badroom.

  • PDF

A Study on the Analysis of Architectural Environments in Medium and Small Scale Elderly Care Facilities (고령화에 따른 중소규모 노인요양원의 건축환경 분석에 관한 연구)

  • Kim, Heung-Gee;Kim, Yong-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.65-72
    • /
    • 2015
  • Recently the concerns of aging & care according to the aged Society were on the increase about Home for the elderly facility. In order to moment, the purpose of this study is to analyze planning direction and Architectural Environments in medium and small scale Elderly Care Facilities. This survey are used to investigate with latest building data, which is Long-term Care Insurance Code for the Elderly was started on July 2008 in Korea. The results of this paper are as follows. First, various type of home for the elderly and the elderly group homes are spread out, attached to day care center type, nursing home type, city region type, countryside rural type, near the university and remodeling type. Secondly, per capita room area-$6.32m^2$ are sufficient in regal comparison with $6.6m^2$. Thirdly, Sunlight environments is inappropriate condition as south direction proportion-41.95%. According to the present situation various facility type and model for our baby boomers generation should be more developed with preemptive systems of senior welfare concept.

A Study on the Location and Functional Arrangement Characteristics of the Neonatal Intensive Care Unit(NICU) in a Certified Tertiary General Hospital (상급종합병원의 신생아 집중치료실(NICU) 설치 위치 및 기능 배치 특성 연구)

  • Lee, Kee hwan;Park, Seo won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.3
    • /
    • pp.35-44
    • /
    • 2024
  • Purpose: The purpose of this study is to present basic data on installation location, functional connection, and arrangement to be considered when planning a neonatal intensive care unit in a certified tertiary general hospital. Method: Review the facility standards related to the neonatal intensive care unit, such as laws and guidelines, and select a Certified Tertiary General Hospital as a case hospital among the Neonatal Intensive Care Regional Centers designated by the Ministry of Health and Welfare to analyze the placement characteristics of major NICU components such as the location of the NICU installation, the connection of movement between adjacent facilities and functions, and the treatment room and accessory room. Results and Implications: NICU is a facility for critically ill babies among newborns and needs to consider more about infection and patient management compared to adult intensive care units, which not only install close to delivery-related facilities to enable immediate action after childbirth, but also divide the treatment room into open rooms and allow access to the attached rooms through dedicated corridors to minimize movement in the treatment room.

A Study on the Change of Distance between the Cemetery and the City caused by Modernization - Through Comparative Analysis between Paris and Seoul - (근대화로 인한 묘지와 도시 사이의 거리 변화에 관한 연구 - 파리와 서울의 비교를 통해 -)

  • Kee, Se-Ho
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.97-108
    • /
    • 2018
  • "Death is the side of life which is turned away from us." The life of people in Seoul, however, is disconnected from death. Why? This article compares the historical changes in the cemetery disposition of Paris and Seoul to answer this question. The cemetery is always a meeting place between the living and the dead. In pre-modern cities, the cemetery was close to the people's daily life. However, the fundamental change of urban structure due to modernization has a great influence on the cemetery. With the advent of the train, the world has shrunk and the city has expanded unprecedentedly. In such a situation, the cemetery is expelled to the outside of the city. However, while Paris and Seoul share the same overall flow, they responded differently to the plans for the establishment of large-scale remote cemeteries. In Paris, the plan was canceled by citizens who value their relationship with the dead. On the other hand, Seoul was unable to manage the cemetery due to social confusion in 20th century. All cemeteries were expelled as industrialization began. As a result, there is no public cemetery or ossuary at present in Seoul. In Seoul, about 20 years ago however, a new kind of place for the dead began to appear. It is an ossuary attached to religious facilities. In other words, the current cemetery of Seoul is divided into two forms : the public cemetery, which is expelled from the city, and the private ossuary, which is attached to religious facilities built in the city.

A Study on the Educational Interactive Globe System using Physical Computing (피지컬 컴퓨팅을 이용한 교육용 인터렉티브 지구본 시스템에 관한 연구)

  • Kim, Gi-Bong;Yang, Hwang-Kyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.4
    • /
    • pp.511-516
    • /
    • 2011
  • Recently, the development of computing technology and experiential content for the increased interest in education and cultural facilities to target children and young people experience learning and experiential entertainment systems require a high propensity to invest and are. In this paper, for the 13.56MHz band RFID Reader and Tag RFID technology using the proposed interactive educational globe. Active tags attached to sensors attached to the globe were presented in the RFID reader, arduino and sensors in conjunction with Google Earth COM API was constructed through the physical computing educational system.

A Method for monitoring air pollution using base stations (이동통신 기지국을 이용한 대기환경 모니터링)

  • Oh, Hyun-Jung;Lee, Jae-Wook;Baik, Song-Hoon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.205-208
    • /
    • 2008
  • This article presents a methodology for the monitoring of air pollution. All over the world, the interest in the environment has been continuously increasing. Unfortunately, much of this interest is due to emerging problems, such as the greenhouse effect and climate change. For this reason, research into carbon dioxide, which causes the greenhouse effect, is progressing rapidly. This article presents a method of measuring the level of carbon dioxide and other substances in the air through the utilization of mobile-networking base stations and measured data. First of all, sensors are attached at the appropriate position of the mobile-networking base stations. These sensors will measure the air quality in their respective positions, and send sensor data to an urban management center via network gateways and data-collecting systems. The measured data can be used for various purposes. In general, it can be used to measure the air quality, which can then be used as a basis for urban planning. The method described herein utilizes airpollution sensors that are attached to the base stations in different locations and at varying heights. The data obtained hereby will be applicable in many fields. At this time this is simply a methodology, however we hope that it will lead to a practical application.

  • PDF

Performance of Decompression Orifices Attached to Indoor Hydrant Discharge Outlets (옥내소화전 방수구에 부착되는 감압오리피스의 감압성능에 관한 연구)

  • Park, Bong-Rae;Lee, Meng-Ro;Jang, Kyung-Nam;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.6-12
    • /
    • 2015
  • Indoor hydrant facilities are used to fight initial fires before more intense fire extinguishing activities. Fire extinguishing facilities should ensure good fire extinguishing performance and the safety of users. Indoor hydrant facilities are mostly installed in buildings and facilities, and users must manipulate valves, hoses, and nozzles manually. When the discharge pressure is higher than 0.70 MPa, there is a high possibility that problems with manipulation and hose breakdown can occur. To prevent these problems, a method to attach orifice-type decompression valves to the angle valves of indoor hydrant discharge outlets has frequently been used for decompression methods. However, the decompression performance was reduced due to structural problems of the decompression valves over time. Accordingly, based on three-stage initial pressures, applicable pressure ranges were selected by measuring the decompression performance according to the diameter of the decompression orifices. Based on the data, stable decompression valve models are proposed. These models have the lowest decrease in decompression performance, regardless of time.

Physical and Biological Performance Evaluation of Disinfection Systems for Transportation Vehicles against AI Virus

  • Chung, Hansung;Choi, Kwanghoon;Kim, Sungkwan;Kim, Sukwon;Lee, Kyungwoo;Choe, Nonghoon
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.7
    • /
    • pp.956-966
    • /
    • 2021
  • To prevent the outbreak of infectious diseases that inflict huge economic and social losses, domestic livestock farms and related facilities have introduced automatic and semiautomatic disinfectant solution-spraying systems for vehicles. However, the facility standards and specifications vary by manufacturer, and no scientific performance evaluation has been conducted. The puropose of this study is to develop physical and biological evaluation methods. Physical and biological appraisals were conducted using two types of disinfection facilities (tunnel- and U-type) and two types of vehicles (passenger car, truck). Water-sensitive paper was used to evaluate the physical performance values for the disinfection facilities. In addition, to assess their biological performance, carriers containing low-pathogenic avian influenza virus were attached to vehicles, and the viral reduction was measured after the vehicles moved through the facility. The tunnel-type had rates of coverage in the range of 70-90% for the passenger car and 60-90% for the truck. At least 4-log virus reduction after spraying for 1-5 min was shown for both vehicles. For the U-type facility evaluation, the coverage rates were in the range of 60-90% for the passenger car and at least 90% for the truck. More than 4-log viral reduction was estimated within a spraying time of 5 min. To reduce viruses on the surface of vehicles by at least 4 log within a short period, the disinfectant solution should cover at least 71% of the pathogens. In conclusion, we were able to assess the physical and biological performance criteria for disinfection facilities aboard transportation vehicles.