• Title/Summary/Keyword: assurance system

Search Result 948, Processing Time 0.028 seconds

A Dynamic Management Technique for Weighted Testcases in Software Testing (가중치를 이용한 소프트웨어 테스트케이스 동적 관리 기법)

  • Han, Sang-Hyuck;Jung, Jung-Su;Jin, Seung-Il;Kim, Young-Kuk
    • The KIPS Transactions:PartD
    • /
    • v.17D no.6
    • /
    • pp.423-430
    • /
    • 2010
  • As software becomes large-scale and complicated, the need for Quality Assurance and management is increased and software testing is becoming more important. The main aims of software testing are not only detecting and handling the defects in the system but also investigating and managing the present system. But automatic testing tools require lots of time and efforts to detect and manage the risk in the system because test-cases used in the general automatic testing tools have the simply static information. In this thesis, the dynamic management technique for weighted testcases is designed to test the high-risk testcases preferentially by giving the testcases dynamic weight.

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System (방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가)

  • Cho Kwang Hwan;Choi Jinho;Shin Dong Oh;Kwon Soo Il;Choi Doo Ho;Kim Yong Ho;Lee Sang Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.186-191
    • /
    • 2004
  • The periodic Quality Assurance (QA) of each radiation treatment related equipments is important one, but quality assurance of the radiation treatment planning system (RTPS) is still not sufficient rather than other related equipments in clinics. Therefore, this study will present and test the periodic QA program to compare, evaluation the efficiency of the treatment planning systems. This QA program is divided to terms for the input, output devices and dosimetric data and categorized to the weekly, monthly, yearly and non-periodically with respect to the job time, frequency of error, priority of importance. CT images of the water equivalent solid phantom with a heterogeneity condition are input into the RTPS to proceed the test. The actual measurement data are obtained by using the ion chamber for the 6 MV, 10 MV photon beam, then compared a calculation data with a measurement data to evaluate the accuracy of the RTPS. Most of results for the accuracy of geometry and beam data are agreed within the error criteria which is recommended from the various advanced country and related societies. This result can be applied to the periodic QA program to improve the treatment outcome as a proper model in Korea and used to evaluate the accuracy of the RTPS.

  • PDF

Analysis of Perceptions on Accreditation System of Vocational Training Providers and Measures to Improve the Accreditation System (직업훈련기관 인증평가에 대한 인식 및 개선방안 연구)

  • Ko, Hye-Won;Lee, Chul-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.694-704
    • /
    • 2021
  • To improve the quality of government-funded vocational training, an accreditation system of vocational training providers has been implemented since 2015. The purpose of this study was to suggest improvement measures by analyzing the accreditation system and the perceptions surrounding it. To this end, accreditation systems from European countries, such as Germany and the UK, as well as related domestic systems, were reviewed. Two surveys were administered to 131 appraisers and 370 vocational training providers. The study results showed that changes to the standard and accreditation processes are not needed at this point. In the long term, however, it will be necessary to request that vocational training providers adopt their quality assurance system. In addition, both appraisers and vocational training providers responded that the accreditation system is being established to increase the quality assurance system within vocational training providers. Based on the study results, several implications for improving the accreditation system were suggested as follows: a vocational training enhancement centered on outstanding vocational training providers; an accreditation system simplification for short-term vocational training providers; a stronger monitoring system during the accreditation period; and an operation of outcome-based accreditation.

Application and Analysis of the Paradigm of Software Safety Assurance for a Digital Reactor Protection System in Nuclear Power Plants (원전 디지털 원자로보호계통 소프트웨어 안전보증 패러다임 적용 및 분석)

  • Kwon, Kee-Choon;Lee, Jang-Soo;Jee, Eunkyoung
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.6
    • /
    • pp.335-342
    • /
    • 2017
  • In the verification and validation procedures regarding the safety-critical software of nuclear power plants for the attainment of the requisite license from the regulatory body, it is difficult to judge the safety and dependability of the development, implementation, and validation activities through a simple reading and review of the documentation. Therefore, these activities, especially safety assurance activities, require systematic evaluation techniques to determine that software faults are acceptable level. In this study, a safety case methodology is applied in an assessment of the level and depth of the results of the development and validation of a manufacturer in its targeting of the bistable processor of a digital reactor protection system, and the evaluation results are analyzed. This study confirms the possibility of an effective supplementation of the existing safety demonstration method through the application of the employed safety case methodology.

A Study on the Microbial Measurement for Cosmetics Using Automated Methods (자동화 장비를 사용한 화장품중의 미생물 검출에 대한 연구)

  • Kim Eun-Young;Jang Seok-Tae;Choung Soung-Oun;Hong Tae-Won
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.4 s.48
    • /
    • pp.549-553
    • /
    • 2004
  • ATP bioluminescence system and impedance system were evaluated with the objective of reducing the time for microbial analysis of cosmetics formulations from 72 to 24 h. The meaningful correlation (at least $95\%$) was achieved when emulsion were artificially contaminated with low levels of different organisms, including Pseudomonas aeruinosa, Staphylococcus aureus, Escherichia coli and Ralstonia mannitolilytica. The standard agar plate method, ATP bioluminescence and impedance method were used for in this study. Successful evaluation and validation of automated systems has enabled the introduction of ATP bioluminescence and impedance method into routine use within the microbiology laboratory. This has provided a rapid assessment of product quality, resulting in faster throughput and resource maximization.

Analysis of Quality Audit Points by the comparison of ISO/CD 9000-3 : 1995 and ISO 9001 : Quality System - Life Cycle Activities (ISO/CD 9000-3:1995와 ISO 9001의 비교를 통한 품질감사 점검사항 분석 :품질시스뎀 -생명주기 활동을 중심으로)

  • 이종무
    • Journal of the Korea Society of Computer and Information
    • /
    • v.1 no.1
    • /
    • pp.65-82
    • /
    • 1996
  • The assurance of software product. which Is different to other products. is very complex because of Its characteristics. The use of objective development standards or guidelines and the confirmation to meet user's requirements are Important to achieve the software quality system. Moreover correct understanding of qualitv standards and continuous applications of check-points for qualify audit are necessary. ISO 9000 series. which are International standards. were made for the qualify assurance. Among them. ISO 9000-3 is the quality management and quality assurance standards for applying ISO 9001 to the design. development. supply. installation and maintenance of software. The newly revised ISO/CD 9000-3:1995 contains a lot of enforced changes within ISO 9001 framework - quality standards for manufactured products. This paper analyses the revised ISO 9000-3 by comparing it to ISO 9001. and derives quality audit points to use for qualify audit In future.

  • PDF

The Verification Method for Missing Software Standardization in Weapon System - Focused on Firmware (무기체계 소프트웨어 규격화 누락여부 검증 방안 - 펌웨어 중심으로)

  • Song, Chi-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.310-315
    • /
    • 2021
  • In the case of weapon systems used by the military, defense standards are applied for economical and efficient procurement, management, and maintenance. Defense specifications are documents describing procedures and methods for determining whether technical requirements for products and services are consistent and apply to the production of weapon systems, quality assurance, and configuration management. Software is also subject to defense specifications, and is documented and managed in the same way as other defense specifications. Sometimes it happened to be standardized without some(or all) software. In this case, a competitive contract is impossible and it may affect the quality of weapon systems because the manufacturer arbitrarily changes the software without prior approval. So, software standardization is required, but it is very difficult to verify for firmware installed in hardware. This paper proposed a verification method for g software standardization, and we expect it will contribute to the efficient production and quality assurance of weapon systems.

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study

  • Oh, Se An;Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.2
    • /
    • pp.108-115
    • /
    • 2022
  • Background: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and Brain-LAB) between June 2019 and March 2021. We analyzed the multileaf collimator DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1% (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). Conclusion: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.

Security Evaluation Criteria of Electronic Payment System (전자 지불 시스템의 보안 평가 기준)

  • 신장균;황재준
    • Proceedings of the CALSEC Conference
    • /
    • 1999.07b
    • /
    • pp.491-500
    • /
    • 1999
  • Recent increase of commercial network Integration to World Wide Web(WWW) shifts an ordinary commerce to electronic environment. This draws more people to examine re-assurance of their secure transaction. This study investigates current status of security methodology for Electronic Payment System and extracts important axis of security level for electronic payment. Using these axis as security evaluation criteria, the research proposes a security matrix which consists of four different level of security granularity, hence allowing evaluation of a nation-wide credit card based payment system. Feasible usage of this matrix contributes to security analysis of the electronic system as whole, hence providing better secured electronic environment.

  • PDF