• Title/Summary/Keyword: assisted

Search Result 4,970, Processing Time 0.034 seconds

A study on the solar assisted heating system with refrigerant as working fluid (냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구)

  • Kim, Ji-Young;Ko, Gawng-Soo;Park, Youn-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

Effects of Robot-Mediated Gait Training Combined with Virtual Reality System on Muscle Activity: A Case Series Research

  • Heo, Seoyoon;Kim, Mooki;Choi, Wansuk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2021-2027
    • /
    • 2020
  • Background: Previous robot-mediated gait training has been proven several limitations such as pointless repeated motion training, decreased presence, etc. In this research, adult stroke patients were participated in robot-mediated gait training accompanied with or without virtual reality program. Objectives: Exploring whether the results indicated virtual reality system has contribution to muscle strength and balance ability. Design: A case series research, cross-over trial. Methods: Eleven participants (male 4, female 7) with adults diagnosed as stroke from medical doctor ware engaged. The participants received 2 treatment sessions of identical duration, robot-assisted gait training with virtual reality and robot-assisted gait training with screen-off randomly crossed over include 1-day for each person of wash-out period. The parameter was muscle activity, the researchers assessed sEMG (surface electromyography). Results: The result showed less muscle activities during training in robot-assisted gait training with virtual reality circumstances, and these indicated muscles were gluteus medius muscle, vastus medialis muscle, vastus intermedius and vastus lateralis muscle, semimembranosus muscle, gastrocnemius-lateral head, and soleus muscle (P<.05). Conclusion: In this study, we analyzed the outcome of muscle activity for clinical inference of robot-assisted gait training with virtual reality (VR). Less muscle activity was measured in the treatment accompanied by VR, therefore, a more systematic, in-depth and well-founded level of follow-up research is needed.

Analysis on Acceptance and Use of Technology for Elementary School Teachers in Telepresence Robot-assisted Learning (원격 로봇보조학습에 대한 초등교사의 기술수용도 분석)

  • Lee, Hyewon;Han, JeongHye
    • Journal of The Korean Association of Information Education
    • /
    • v.23 no.6
    • /
    • pp.599-606
    • /
    • 2019
  • Telepresence robot-assisted learning can provide opportunities of education for students who are in vulnerable physical, intellectual, cultural or environmental conditions. It is to be applied in international virtual education for global citizenship education. To date, the study of acceptance model has been conducted only for preservice teachers, and post-intention for use is not considered. This paper identified whether there are significant differences by gender or years of experience from elementary school teachers on it and the basic factors that affect the acceptance intentions for it. Factors related to intention to use for a telepresence robot were investigated, and a questionnaire about post-intention for use was made after participants operated. The results showed that elementary school teachers did not have a significant difference in each factor by gender. The experienced teachers showed no difficulty in using it. It was shown that PU, ATT, PENJ, SI and Ttrust were all extremely significant factors to affect acceptance intentions. It will be possible to establish educational information policies based on the acceptance intentions of elementary school teachers on telepresence robot-assisted learning.

The effects of CAI adapting to the level of students' conceptual understanding in concept learning (개념 학습에서 학생들의 개념 이해 수준에 적응적인 CAI의 효과)

  • Kim, Kyung-sun;Kang, Yi-young;Kwon, Hyeok-soon;Wang, Hye-nam;Noh, Tae-hee
    • The Journal of Korean Association of Computer Education
    • /
    • v.9 no.2
    • /
    • pp.79-88
    • /
    • 2006
  • This study investigated the effects of computer-assisted instruction adapting to the level of students' conceptual understanding upon students' conceptual understanding, retention of conceptions, learning motivation, and perception about computer-assisted instruction in concept learning. 94 seventh grade students from a coed middle school in Seoul were randomly assigned to control, CAI, adaptive CAI groups, and were taught about 'motion of molecules' for 7 class periods. Two-way ANCOVA results revealed that the scores of a conception test and a learning motivation test for the adaptive CAI group were significantly higher than those for the control group. The scores of a retention test of conceptions for the adaptive CAI group were significantly higher than those for other two groups. There were no significant interactions between the instruction and the level of previous achievement in the scores of the conception test, the learning motivation test, and the retention test of conceptions. The perception about computer-assisted instruction for the students of the adaptive CAI group were more positive than those for the students of the CAI group.

  • PDF

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

Design and Implementation of CAPI System for PSED Using Blaise Software (Blaise 소프트웨어를 이용한 장애인고용패널조사 CAPI 시스템의 설계 및 구현)

  • Lee, Woo-Il
    • Survey Research
    • /
    • v.11 no.1
    • /
    • pp.107-121
    • /
    • 2010
  • The purpose of this paper is to design and implement a Computer Assisted Personal Interviewing (CAPI) system for Panel Survey of Employment for the Disabled (PSED) using Blaise software developed by Statistics Netherlands which is a powerful and flexible system used for computer-assisted survey processing. CAPI system for PSED is consisted of three parts, which are survey management program, electronic questionnaire program, and postprocessing program. These programs are constructed with modular approach and are integrated into CAPI system. The developed software is highlighted in its reusability which results in the improved efficiency and reduced cost of software maintenance. CAPI system for PSED proved its effectiveness in carrying out the survey by guaranteeing correctness of survey data, improved timeliness of survey, easy reforming the questionnaires, easy control on the interviewers, and rapid data processing in spite of the complexity of PSED.

  • PDF

Implant assisted obturator in patient after maxillectomy: a case report (상악골 절제 환자에서 임플란트를 이용한 구개폐쇄장치 증례)

  • Seo, Yoon-Hee;Lee, Joon-Seok;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.322-329
    • /
    • 2016
  • Reconstruction of the maxillectomy with an obturator is to restore masticatory, swallowing, phonetic and esthetic problems. Stress created by lateral forces is minimized by the proper selection of an occlusal scheme, elimination of premature occlusal contacts, and wide distribution of supporting area. It should be considered that properly designed retainers reduce the stresses transmitted to the abutment while the obturator is in function. The following clinical report presents palatal obturator treatment with implant assisted removable partial denture (IARPD) design that restores normal function and esthetics in patients who experienced maxillectomy and dental implant failure.

Thrust Characteristics of a Laser-Assisted Pulsed Plasma Thruster

  • Masatoshi Kawakami;Hideyuki Horisawa;Kim, Itsuro ura
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.294-299
    • /
    • 2004
  • An assessment of a novel laser-electric hybrid propulsion system was conducted, in which a laser-induced plasma was induced through laser beam irradiation onto a solid target and accelerated by electrical means instead of direct acceleration only by using a laser beam. A fundamental study of newly developed rectangular laser-assisted pulsed-plasma thruster (PPT) was conducted. On discharge characteristics and thrust performances with increased peak current compared to our previous study to increase effects of electromagnetic forces on plasma acceleration. Maximum peak current increased for our early study by increasing electromagnetic effects in a laser assisted PPT. At 8.65 J discharge energy, the maximum current reached about 8000 A. Plasma behaviors emitted from a thruster in various cases were observed with an ICCD camera. It was shown that the plasma behaviors were almost identical between low and high voltage cases in initial several hundred nanoseconds, however, plasma emission with longer duration was observed in higher voltage cases. Canted current sheet structures were also observed in the higher voltage cases using a larger capacitor. With a newly developed torsion-balance type thrust stand, thrust performances of laser assisted PPT could be estimated. The impulse bit and specific impulse linearly increased. On the other hand, coupling coefficient and the thrust efficiency did not increase linearly. The coupling coefficient decreased with energy showing maximum value (20.8 ?Nsec/J) at 0 J, or in a pure laser ablation cases. Thrust efficiency first decreased with energy from 0 to 1.4 J and then increased linearly with energy from 1.4 J to 8.6 J. At 8.65 J operation, impulse bit of 38.1 ?Nsec, specific impulse of 3791 sec, thrust efficiency of 8 %, and coupling coefficient of 4.3 ?Nsec/J were obtained.

  • PDF

EFFECT OF CYCLIC STRAIN RATE AND SULFIDES ON ENVIRONMENTALLY ASSISTED CRACKING BEHAVIORS OF SA508 GR. 1A LOW ALLOY STEEL IN DEOXYGENATED WATER AT 310℃

  • Jang, Hun;Cho, Hyun-Chul;Jang, Chang-Heui;Kim, Tae-Soon;Moon, Chan-Kook
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.225-232
    • /
    • 2008
  • To understand the effect of the cyclic strain rate on the environmentally assisted cracking behaviors of SA508 Gr.1a low alloy steel in deoxygenated water at $310^{\circ}C$, the fatigue surface and a sectioned area of specimens were observed after low cycle fatigue tests. On the fatigue surface of the specimen tested at a strain rate of 0.008 %/s, unclear ductile striations and a blunt crack tip were observed. Therefore, metal dissolution could be the main cracking mechanism of the material at this strain rate. On the other hand, on the fatigue surfaces of the specimens tested at strain rates of 0.04 and 0.4 %/s, brittle cracks and flat facets, which are evidences of the hydrogen induced cracking, were observed. In addition, a tendency of linkage between the main crack and the micro-cracks was observed on the sectioned area. Therefore, at higher strain rates, the main cracking mechanism could be hydrogen induced cracking. Additionally, evidence of the dissolved MnS inclusions was observed on the fatigue surface from energy dispersive x-ray spectrometer analyses. Thus, despite the low sulfur content of the test material, the sulfides seem to contribute to environmentally assisted cracking of SA508 Gr.1a low alloy steel in deoxygenated water at $310^{\circ}C$.

Ultrasonically Assisted Grinding for Mirror Surface Finishing of Dies with Electroplated Diamond Tools

  • Isobe, Hiromi;Hara, Keisuke;Kyusojin, Akira;Okada, Manabu;Yoshihara, Hideo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.38-43
    • /
    • 2007
  • This paper describes ultrasonically assisted grinding used to obtain a glossy surface quickly and precisely. High-quality surfaces are required for plastic injection molding dies used in the production of plastic parts such as dials for cellular phones. Traditionally, in order to finish the dies, manual polishing by a skilled worker has been required after the machining processes, such as electro discharge machining (EDM), which leaves an affected layer, and milling, which leaves tooling marks. However, manual polishing causes detrimental geometrical deviations of the die and consumes several days to finish a die surface. Therefore, a machining process for finishing dies without manual polishing to improve the surface roughness and form accuracy would be extremely valuable. In this study, a 3D positioning machine equipped with an ultrasonic spindle was used to conduct grinding experiments. An electroplated diamond tool was used for these experiments. Generally, diamond tools cannot grind steel because of excessive wear as a result of carbon atoms diffusing into bulk steel and chips. However, ultrasonically assisted grinding can achieve a fine surface (roughness Rz of $0.4{\mu}m$) on die steel without severe tool wear. The final aim of this study is to realize mirror surface grinding for injection molding dies without manual polishing. To do this, it is necessary to fabricate an electroplated diamond tool with high form accuracy and low run-out. This paper describes a tool-making method for high precision grinding and the grinding performance of a self-electroplated tool. The ground surface textures, tool performance and tool life were investigated A ground surface roughness Rz of 0.14 um was achieved Our results show that the spindle speed, feed rate and cross feed affected the surface texture. One tool could finish $5000mm^2$ of die steel surface without any deterioration of the ground surface roughness.