• Title/Summary/Keyword: assisted

Search Result 4,955, Processing Time 0.029 seconds

An Efficient Assisted-GPS Acquisition Method in Weak Signal Environment (약 신호 환경에서 효율적인 A-GPS 초기동기 방법)

  • 박상현;이상정
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.1
    • /
    • pp.96-102
    • /
    • 2004
  • For sensitivity enhancement, the general assisted-GPS acquisition method adopts not only the coherent accumulation technique but also the non-coherent accumulation technique since the long coherent accumulation period increases the number of frequency search cells. But the non-coherent accumulation technique causes tile squaring loss, which is a dominant factor among the acquisition losses of assisted GPS dealing with weak GPS signals. This paper derives the squaring loss of the previous assisted-GPS acquisition method and proposes an assisted-GPS acquisition method for solving the problem of squaring loss in weak signal environment. In this paper, it is explained that the proposed assisted-GPS acquisition method prevents the squaring loss using a coupled coherent accumulation technique and the number of search cells of the proposed assisted-GPS acquisition method is much smaller than that of the previous assisted-GPS acquisition method. Finally, through the simulation by the GPS simulator, the acquisition success rate of the proposed assisted-GPS acquisition method is compared with that of the previous assisted-GPS acquisition method and the acquisition improvements are shown in weak signal environment.

After Lasek Surgeried and TransPRK Surgeried for Myopia, Comparison of High-order Aberrations (근시에서의 라섹과 TransPRK라섹 수술 후 고위수차 비교)

  • Park, Jun-Sung
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.2
    • /
    • pp.372-377
    • /
    • 2015
  • Purpose: The aim of this study is to compare total high order aberrations between surgery which uses TransPRK and general laser assisted sub-epithelial keratomileusis. Methods: The patients who had general laser assisted sub-epithelial and TransPRK laser assisted sub-epithelial by visiting ophthalmic clinic in Ulsan from January 2014 to August 2014 was researched. Results: When comparing total high order aberrations before and after operation, it was found that total high order aberration in general laser assisted sub-epithelial group increased to $0.222{\pm}0.078{\mu}m$ from $0.074{\pm}0.019{\mu}m$ while that in TransPRK assisted sub-epithelial group increased to $0.179{\pm}0.045{\mu}m$ from $0.076{\pm}0.032{\mu}m$. When comparing the increment in total high order aberrations between two groups after surgery, it was found that the increments of TransPRK assisted sub-epithelial group were statistically smaller than that of general laser assisted sub-epithelial group (p<0.05). Conclusions: This study made a comparative analysis of total high order aberrations between general laser assisted sub-epithelial and TransPRK assisted sub-epithelial which was introduced recently and the result showed a significant difference. The findings of this study suggest that TransPRK assisted sub-epithelial can be used widely in simply improving eye sight and quality of vision by reducing an increase in high order aberration caused by orthokeratology surgery. It is expected that TransPRK assisted sub-epithelial will be helpful for improving the understanding quality of eye sight which occurs by several methods of vision correction surgery.

Microwave-assisted Protein Digestion on Various Locations of a Microplate

  • Lee, Ji-Hye;Park, Se-Hwan;Lee, Sun-Young;Hong, Jang-Mi;Park, Kyu-Hwan;Kim, Hyun-Sik;Kim, Jeong-Kwon
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.84-87
    • /
    • 2011
  • The effectiveness of microwave-assisted protein digestion in different well positions of a 96-well microplate was investigated where microwave-assisted protein digestion of bovine serum albumin was performed in 10 different wells of a 96-well microplate in a microwave oven. Similarly increased sequence coverages (~70%) were generally observed for the 10 microwave-assisted protein digestion samples compared to conventional overnight digestion (63%), which is possibly due to higher miscleavage ratios (~53%) of the samples from microwave-assisted protein digestion than conventional overnight digestion (42.1%). The reproducible results of microwave-assisted digestions from different well positions demonstrate the potential of high-throughput analysis of proteins using microwave-assisted protein digestion.

Analytical Study of the Determination of Distance between the Laser Heat Source and Tool for Laser-Assisted Machining (레이저보조가공에서 열원과 공구 사이의 거리선정을 위한 해석적 연구)

  • Baek, Jong-Tae;Lee, Choon-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.8
    • /
    • pp.699-704
    • /
    • 2015
  • Laser-assisted machining has shown its potential to significantly improve product quality and reduce manufacturing costs; additionally, laser-assisted turning (LAT) and laser-assisted milling (LAM) have been studied by numerous researchers. A research study on the determination of the distance between the laser heat source and the tool for laser-assisted machining, however, has not yet been attempted; we conducted such an analysis by using a finite-element method and heat-transfer equation. The results of this analysis can be used as a reference for the determination of the distance between the laser heat source and the tool for laser-assisted machining.

A Study on the Effect Degree of the Use of Computer Assisted Reporting on the User Satisfaction and Job Performance (컴퓨터활용취재(Computer Assisted Reporting)의 사용도가 만족도 및 직무성과에 미치는 영향 연구)

  • Park Hyun Soo;Yang Kyung Sik;Kim Hyun Soo
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.3
    • /
    • pp.117-135
    • /
    • 2004
  • The purpose of this research is to examination whether End-User Computing relative factors are ap-plied in Computer Assisted Reporting. Computer Assisted Reporting is closely related to End-User Computing, because IT and IS be used by reporting for data gathering and analysis. For the purpose, we've produced a survey, and then studied the effects of the use of Computer Assisted Reporting tools on the report's satisfaction and job performance. As a result, The degree of use of Computer Assisted Reporting significantly affects the degree of satisfaction and job performance. for this reason, this research can give an insight for the extension of End-User Computing relative research.

  • PDF

A Robot of Animal-Assisted-Therapy for the Psychotherapy of Handicapped Child (장애아동의 심리치료를 위한 동물매개치료용 로봇)

  • Choi, Chul-Hee;Choi, Byung-Jae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.4 no.3
    • /
    • pp.112-117
    • /
    • 2009
  • An animal assisted therapy (AAT) for handicapped child's psychotherapy has been reported by some researches. A robot can be substituted for the role of a real animal of the AAT. The robot for the AAT is called RAT (Robot Assisted Therapy). It consists of four parts: microprocessor-based MCU(Micro Control Unit), sensing part with various sensors, the movement part operated by some motors, and the exterior with soft feel. We will here introduce the RAT.

  • PDF

Utilization and Effects of Peer-Assisted Learning in Basic Medical Education (기본의학교육에서 동료지원학습의 활용과 효과)

  • Roh, HyeRin
    • Korean Medical Education Review
    • /
    • v.23 no.1
    • /
    • pp.11-22
    • /
    • 2021
  • This review of the literature explored the experiences and effects of peer-assisted learning in basic medical education. Peer-assisted learning is most commonly utilized to teach clinical skills (including technical skills) and medical knowledge (76.4%). It has also been used, albeit less frequently, to facilitate small-group discussions including problem-based learning, to promote students' personal and professional development, to provide mentoring for career development and adaptation to school, to give tutoring to at-risk students, and to implement work-based learning in clinical settings. Near-peer learning is a common type. The use of active learning techniques and digital technology has been increasingly reported. Students' leadership had frequently been described. Student tutor training, programs for teaching skills, institutional support, and assessments have been conducted for effective peer-assisted learning. There is considerable positive evidence that peer-assisted learning is effective in teaching simple clinical skills and medical knowledge for tutees. However, its effects on complex skills and knowledge, small-group discussions, personal and professional development, peer mentoring, and work-based learning have rarely been studied. Additionally, little evidence exists regarding whether peer-assisted learning is effective for student tutors. Further research is needed to develop peer-assisted learning programs and to investigate their learning effects on student tutors, small-group discussion facilitation, personal and professional development, peer mentoring, and peer-led work-based learning in the clinical setting in South Korea. Formal programs and system advancement for a student-led learning culture is needed for effective peer-assisted learning.

The effect of various assisted hatching techniques on the mouse early embryo development

  • Park, Sung Baek;Kim, Hye Jin;Choi, Young Bae;Ahn, Kwang Hwa;Lee, Kee Hwan;Yang, Jung Bo;Yu, Chang Seok;Seo, Byoung Boo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.41 no.2
    • /
    • pp.68-74
    • /
    • 2014
  • Objective: In search of an ideal method of assisted hatching (AH), we compared the effects of conventional micropipette-AH and laser-AH on the blastocyst formation rate (BFR) and blastocyst cell numbers. Methods: Four-to five-week-old ICR female mice were paired with male mice after superovulation using Pregnant mare's serum gonadotropin (PMSG) and hCG. The two-cell embryos were flushed from the oviducts of female mice. The retrieved two-cell embryos underwent one of five AH procedures: single mechanical assisted hatching (sMAH); cross mechanical assisted hatching (cMAH); single laser assisted hatching (sLAH); quarter laser assisted hatching (qLAH); and quarter laser zona thinning assisted hatching (qLZT-AH). After 72 hours incubation, double immunofluorescence staining was performed. Results: Following a 72 hours incubation, a higher hatching BFR was observed in the control, sMAH, cMAH, and sLAH groups, compared to those in the qLAH and qLZT-AH groups (p<0.05). The hatched BFR was significantly higher in the qLAH and qLZT-AH groups than in the others (p<0.05 for each group). The inner cell mass (ICM) was higher in the control and sMAH group (p<0.05). The trophectoderm cell number was higher in the cMAH and qLAH groups (p<0.05). Conclusion: Our results showed that the hatched BFR was higher in groups exposed the the qLAH and qLZT-AH methods compared to groups exposed to other AH methods. In the qLAH group, although the total cell number was significantly higher than in controls, the ICM ratio was significantly lower in than controls.

Design evaluation Items for Assisted Living Facilities for the Elderly (반의존 노인을 위한 시설주거의 디자인 평가요소 -미국 노인생활보조주택을 중심으로-)

  • 오찬옥
    • Korean Institute of Interior Design Journal
    • /
    • no.20
    • /
    • pp.40-47
    • /
    • 1999
  • The purpose of this study was to identify design evaluation items for assisted living facilities for the elderly. To achieve this purpose, the 23 design issues in assisted living facilities were examined through literature analysis. Then, the field studies were carried out by using these items and by asking open questions, or any other suggestions for unexpected, but important design issues in their facilities. The field studies were conducted through interviews with several residents and surveys with staff in six selected assisted living facilities in Cincinnati, Ohio. Finally, the 23 design evaluation items for assisted living facilities were identified. These items can be used as evaluation criteria or design guidelines for assisted living facilities.

  • PDF

A Study of Gas-Assisted Injection Molding of 17" Flat Monitor Front Cover (17" 평면 모니터 Front Cover의 가스사출성형에 관한 연구)

  • Kim, Hong-Seok;Son, Jung-Sik;Seo, Tae-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.766-771
    • /
    • 2001
  • Gas-assisted injection molding is an innovative low-pressure injection molding technique that can provide numerous benefits such as reduced part warpage, excellent surface quality without sink marks, low injection pressure, and greater design flexibility. However, the adoption of gas-assisted injection molding may cause unexpected defects if the gas channel design is not conducted properly. The objective of this paper is to broaden the understanding of gas-assisted injection molding by summarizing the design procedures and experimental results of the gas-assisted injection molding of a 17" flat monitor front cover. The gas channels were designed by using Moldflow(MF/GAS) simulations and a 450 ton injection molding machine with a 5 stage pressure control gas kit was used in the experiments.

  • PDF