• 제목/요약/키워드: assessing integrity

검색결과 68건 처리시간 0.023초

수치해석과 실험에 의한 SINTAP 용접 구조물 균열 평가법의 검증 (Finite Element and Experimental Validation of SINTAP Defect Assessment Procedure for Welded Structure)

  • 김윤재;김진수
    • Journal of Welding and Joining
    • /
    • 제22권1호
    • /
    • pp.50-57
    • /
    • 2004
  • This paper provides FE and experimental validation of the defect assessment method for strength mismatched welded structures, resulting from the Brite Euram SINTAP (Structural Integrity Assessment Procedures for European Industry) project. This shows that the proposed method is conservative, and that the degree of conservatism is similar to that embedded in the methods for homogeneous structures. It provides confidence in the use of the proposed SINTAP method for assessing defective weld strength mismatched structures.

Assessing the Geometric Integrity of Cylindrical Storage Tanks: A Comparative Study Using Static Terrestrial Laser Scanning and Total Station

  • Mansour Alghamdi;Jinha Jung
    • 대한원격탐사학회지
    • /
    • 제40권3호
    • /
    • pp.243-255
    • /
    • 2024
  • This study compares Static Terrestrial Laser Scanning (STLS)with the conventional Total Station (TS) method for the geometric assessment of cylindrical storage tanks. With the crucial need for maintaining tank integrity in the oil and gas industry, STLS and TS methods are evaluated for their efficacy in assessing tank deformations. Using STLS and TS, the roundness and verticality of two cylindrical tanks were examined. A deformation analysis based on American Petroleum Institute (API) standards was then provided. Key objectives included comparing the two methods according to API standards, evaluating the workflow for STLS point cloud processing, and presenting the pros and cons of the STLS method for tank geometric assessment. The study found that STLS, with its detailed and high-resolution data acquisition, offers a substantial advantage in having a comprehensive structural assessment over TS. However, STLS requires more processing time and prior knowledge about the data to tune certain parameters and achieve accurate assessment. The project outcomes intend to enhance industry professionals' understanding of applying STLS and TS to tank assessments, helping them choose the best method for their specific requirements.

신뢰성해석에 의한 초기균열을 갖는 구조부재의 건전성 평가방법 (The Integrity Assessment Method of Initailly Cracked Structural Components by Reliability Analysis)

  • 임상전;변태욱
    • 대한조선학회논문집
    • /
    • 제30권2호
    • /
    • pp.161-176
    • /
    • 1993
  • 본 논문에서는 주어진 상황에 맞추어 적절한 수준에서 건전성평가를 수행하기 위하여, 개정된 BSI PD 6493의 3단계 평가방법에 균열성장효과를 고려한 건전성 평가방법과 균열의 안정성장을 엄밀히 고려할 수 있는 안정성 평가방법(stability assessment method:SAM)과 더불어 소성 붕괴를 평가하는 극한하중해석을 고려한 건전성 평가방법을 정식화하였다. 또한 신뢰성이론 중 2차 모멘트방법을 사용하여, center cracked panel(CCP) 시편과 관통균열을 갖는 파이프에 대하여, 신뢰성해석에 의한 건전성 평가를 수행하였다. 신뢰성해석을 수행하는데 필요한 확률변수들의 통계적 특성은 지금까지 보고된 그들 변수들의 실험자료와 통계해석의 결과들을 이용하였다. 또 기존의 신뢰성해석에서 정확한 파괴확률을 구할 수 있는 Monte Carlo 방법을 사용하여, 본 논문의 유용성을 검토하였다.

  • PDF

Information Security Activity of Analysis Phase in Information Security Model in Accordance with SDLC

  • Shin, Seong-Yoon;Lee, Tae-Wuk
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권11호
    • /
    • pp.79-83
    • /
    • 2016
  • In this paper, we define four levels of analysis, design, implementation, and testing of the configuration of the development phase by S/W development life cycle. In particular, it dealt with the stage of the analysis phase to prepare an information system developed intensively. Details of the derivation of the information security requirements, it can be seen that comes from the perspective of confidentiality, integrity, availability and accountability, etc. It dealt with from the first manifestations of the projects planning to final planning to establish information security in activities of the Information Security requirements. As an example exhibited by assessing the information security analysis phase activities of S corporations, it can be seen that the improved sales rise in information security activities.

다변량 로지스틱 회귀분석을 이용한 증기발생기 전열관 ODSCC의 POD곡면 분석 (Evaluation of the Probability of Detection Surface for ODSCC in Steam Generator Tubes Using Multivariate Logistic Regression)

  • 이재봉;박재학;김홍덕;정한섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.250-255
    • /
    • 2007
  • Steam generator tubes play an important role in safety because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. For this reason, the integrity of the tubes is essential in minimizing the leakage possibility of radioactive water. The integrity of the tubes is evaluated based on NDE (non-destructive evaluation) inspection results. Especially ECT (eddy current test) method is usually used for detecting the flaws in steam generator tubes. However, detection capacity of the NDE is not perfect and all of the "real flaws" which actually existing in steam generator tunes is not known by NDE results. Therefore reliability of NDE system is one of the essential parts in assessing the integrity of steam generators. In this study POD (probability of detection) of ECT system for ODSCC in steam generator tubes is evaluated using multivariate logistic regression. The cracked tube specimens are made using the withdrawn steam generator tubes. Therefore the cracks are not artificial but real. Using the multivariate logistic regression method, continuous POD surfaces are evaluated from hit (detection) and miss (no detection) binary data obtained from destructive and non-destructive evaluation of the cracked tubes. Length and depth of cracks are considered in multivariate logistic regression and their effects on detection capacity are evaluated.

  • PDF

국내 호소의 온전성 평가를 위한 저서성 대형무척추동물 다중계량지수(LBMMI)의 개발 (Development of Lakes Benthic Macroinvertebrate-based Multi-metric Index (LBMMI) for Biological Integrity Assessment of Korean Lake)

  • 박근용;김명철;공동수
    • 한국물환경학회지
    • /
    • 제40권5호
    • /
    • pp.243-257
    • /
    • 2024
  • Although lakes are an important part of freshwater, research on biological methods for assessing ecological integrity of Korean lakes is insufficient. Therefore, this study aimed to develop Lakes Benthic Macroinvertebrates Multi-Metric Index (LBMMI) to assess the ecological integrity of lakes in Korea to further understand Korean lake's ecosystem. We used biological data from 388 sampling units of national lake monitoring programs from 2022 to 2023 and water quality data from Water Environment Information System (WEIS). As a result, firstly, reference points and disturbed points were selected through Principal Component Analysis (PCA). Secondly, six core metric elements (Pielou's Evenness index (J), Total number of taxa (To.t), Percent of taxa in insecta (% I.t), Percent of individuals in Oligochaeta and chironomidae(tuble) (% OliCht.i), Percent of taxa in Predator (% Pe.t), and Percent of taxa in Clingers (% CL.t) were selected through discriminant analysis and relationship-test. Lastly, LBMMI was calculated for each sampling point by scoring using core metric elements and five grades were assigned for LBMMI scores using a Beta probability distribution model, with the suitability of LBMMI reviewed by comparing it with TSIKO. LBMMI developed in this study is expected to appropriately assess ecological integrity of Korean lakes and provide a basis for further research on lake environment conservation.

표면 마모결함을 고려한 증기발생기 세관의 구조건전성 평가 (Structural Integrity Evaluation of SG Tube with Surface Wear-type Defects)

  • 김종민;허남수;장윤석;황성식;김정수;김영진
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1618-1625
    • /
    • 2006
  • During the last two decades, several guidelines have been developed and used for assessing the integrity of a defective steam generator (SG) tube that is generally caused by stress corrosion cracking or wall-thinning phenomenon. However, as some of SG tubes are also failed due to fretting and so on, alternative failure estimation schemes are required for relevant defects. In this paper, parametric three-dimensional finite element (FE) analyses are carried out under internal pressure condition to simulate the failure behavior of SG tubes with different defect configurations; elliptical wear, tapered and flat wear type defects. Maximum pressures based on material strengths are obtained from more than a hundred FE results to predict the failure of SG tube. After investigating the effect of key parameters such as defect depth, defect length and wrap angle, simplified failure estimation equations are proposed in relation to the equivalent stress at the deepest point in wear region. Comparison of failure pressures predicted by the proposed estimation scheme with corresponding burst test data showed a good agreement.

Performance evaluation of in-service open web girder steel railway bridge through full scale experimental investigations

  • Sundaram, B. Arun;Kesavan, K.;Parivallal, S.
    • Structural Monitoring and Maintenance
    • /
    • 제6권3호
    • /
    • pp.255-268
    • /
    • 2019
  • Civil infrastructures, such as bridges and tunnels are most important assets and their failure during service will have significant economic and social impact in any country. Behavior of a bridge can be evaluated only through actual monitoring/measurements of bridge members under the loads of interest. Theoretical analysis alone is not a good predictor of the ability of a bridge. In some cases, theoretical analyses can give less effect than actual since theoretical analyses do not consider the actual condition of the bridge, support conditions, level of corrosion and damage in members and connections etc. Hence actual measurements of bridge response should be considered in making decisions on structural integrity, especially in cases of high value bridges (large spans and major crossings). This paper describes in detail the experimental investigations carried out on an open web type steel railway bridge. Strain gages and displacement transducers were installed at critical locations and responses were measured during passage of locomotives. Stresses were evaluated and extrapolated to maximum design loading. The responses measured from the bridge were within the permissible limits. The methodology adopted shall be used for assessing the structural integrity of the bridge for the design loads.

Dynamic Material Testing of Aged Concrete Cores From the Outer Wall of the High-Flux Advanced Neutron Application Reactor

  • JaeHoon Lim;Byoungsun Park;Jongmin Lim;Yun-Young Yang;Sung-Hyo Lee;Sang Soon Cho
    • 방사성폐기물학회지
    • /
    • 제22권2호
    • /
    • pp.139-144
    • /
    • 2024
  • Concrete structures must maintain their shielding abilities and structural integrity over extended operational periods. Despite the widespread use of dry storage systems for spent nuclear fuel, research on the properties of deteriorated concrete and their impact on structural performance remains limited. To address this significant research gap, static and dynamic material testing was conducted on concrete specimens carefully extracted from the outer wall of the High-flux Advanced Neutron Application ReactOr (HANARO), constructed approximately 30 years ago. Despite its age, the results reveal that the concrete maintains its structural integrity impressively well, with static compression tests indicating an average compressive strength exceeding the original design standards. Further dynamic property testing using advanced high-speed material test equipment supported these findings, showing the consistency of dynamic increase factors with those reported in previous studies. These results highlight the importance of monitoring and assessing concrete structures in nuclear facilities for long-term safety and reliability.