• Title/Summary/Keyword: artificial saliva

Search Result 156, Processing Time 0.025 seconds

The influence of saliva pH value on the retention and durability of bar-clip attachments

  • Silva, Antonio Sergio;Aroso, Carlos;Ustrell, Raul;Braga, Ana Cristina;Mendes, Jose Manuel;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.32-38
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS. Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at $37^{\circ}C$ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS. The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION. More acidic pH values were found to have a negative influence on the retention capacity of the attachments.

Plasma Osmolality Controls Dry Forage Intake in Large-type Goats

  • Thang, Tran Van;Sunagawa, Katsunori;Nagamine, Itsuki;Ogura, Go
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.8
    • /
    • pp.1069-1085
    • /
    • 2011
  • In large-type goats that were fed on dry forage twice daily, dry forage intake was markedly suppressed after 40 min of feeding had elapsed. The objective of this study was to clarify whether or not increases in plasma osmolality and subsequent thirst sensations produced by dry forage feeding suppress dry forage intake. Eight large-type male esophageal- and ruminal-fistulated goats (crossbred Japanese Saanen/Nubian, aged 3 to 6 years, weighing $72.3{\pm}2.74$ kg) were used in two experiments conducted under sham feeding conditions. The animals were fed ad libitum a diet of roughly crushed alfalfa hay cubes for 2 h from 10:00 to 12:00 h during two experiments. Water was withheld during feeding in both experiments but was available for a period of 30 min after completion of the 2 h feeding period. In experiment 1, an intraruminal infusion of artificial parotid saliva (RIAPS) in the control replenished saliva lost via the esophageal fistula and an intraruminal infusion of hypertonic solution (RIHS) in the treatment was carried out in order to reproduce the effects of changing salt content due to feed entering the rumen. In experiment 2, the RIHS control was conducted in the same manner as the RIHS treatment of experiment 1. The treatment group consisted of RIHS-with an intravenous infusion of artificial mixed saliva (VIAMS) treatment that was carried out for 3 h to prevent increases in plasma osmolality during feeding. The results of the RIHS treatment in experiment 1 showed that ruminal fluid osmolality increased and then an increase in plasma osmolality was observed. This resulted in the production of thirst sensations and the reduction of cumulative dry forage intake to 43.3% (p<0.05) of the RIAPS control. The results of the RIHS-VIAMS treatment in experiment 2 indicated that ruminal fluid osmolality was the same as the RIHS control but plasma osmolality significantly decreased, and thirst level was markedly reduced. This caused a significant increase of 31.4% (p<0.05) in cumulative dry forage intake in the RIHS-VIAMS treatment compared to the RIHS control. These results indicate that increases in ruminal fluid osmolality during dry forage feeding indirectly suppresses dry forage intake by causing an increase in plasma osmolality and subsequently inducing thirst sensations. The results of the present study suggest that marked decreases in dry forage intake after 40 min of feeding are caused by increases in plasma osmolality and subsequent thirst sensations produced by dry forage feeding.

Shear bond strength of orthodontic bracket with hydrophilic primer (친수성 프라이머를 이용한 교정용 브라켓 접착시의 전단결합강도에 관한 연구)

  • Park, Chul-Wan;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.293-300
    • /
    • 2002
  • The purpose of this study was to evaluate the clinical effectiveness of hydrophilic primer, which claim to retain adequate bond strength on moistened enamel resulting from moisture or saliva contamination, by comparing the shear bond strength and adhesive failure patterns of brackets bonded using hydrophilic primer and conventional hydrophobic primer. Brackets were bonded to human premolars embedded in metal cylinders utilizing light cured adhesive, primed with either a hydrophilic primer(Transbond fm primer) or a conventional hydrophobic primer(Transbond XT primer). Each sample was exposed to varying degrees of artificial saliva contamination during the priming process. The shear bond strength was measured using a universal testing machine, and the adhesive failure patterns after debonding were visually examined by strereomicroscope and assessed using the adhesive remnant index(ARI). The results were as follows 1. In dry conditions, no significant differences in shear bond strength between Transbond W and Transbond XT primers were found. 2. Transbond MIP primer exhibited a significantly higher shear bond strength than Transbond XT primer in saliva-contaminated conditions, regardless of the degree of contamination. 3. When contaminated with one coat of saliva, Transbond MIP primer did not exhibit significant differences in shear bond strength compared to the dry condition. When contaminated with two coats of saliva, Transbond MIP primer exhibited a singnificantly lower shear bond strength compared to the dry condition. 4. The adhesive remnant index of the adhesive failure pattern had a tendency to decrease, as the degree of saliva contamination increased. Bracket-adhesive interface failure was observed in more than half of the saliva contaminated samples utilizing Transbond MIP primer, whereas the bond failure sites of the Transbond XT primer samples occurred almost exclusively at the adhesive-enamel interface in saliva-contaminated conditions. The results of this study suggest that in cases where moisture control is difficult, Transbond MIP primer is an effective alternative to conventional hydrophobic primers.

THE ANALYSIS OF REMINERALIZATION EFFECT IN FLUORIDE VARNISH USING CONFOCAL LASER SCANNING MICROSCOPE (공초점 레이저 주사 현미경을 이용한 불소 바니쉬 재광화 효과의 분석)

  • Kwon, Ji-Hoon;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.57-64
    • /
    • 2008
  • It is well established that fluoride products play an important role in the prevention and remineralization of carious lesion. Fluoride varnish is a concentrated topical fluoride and varnishes adhere to tooth surface, permitting prolonged fluoride exposure and uptake. In this study, the artificial initial enamel caries was caused on the sound human enamel and divided 60 specimens into three groups. Group 1 and group 2 were treated with the topical application of fluoride varnish and stored in artificial saliva for 1 and 2 weeks. Group 3 was stored in artificial saliva for 2 weeks, which acted as control group. Changes in mineral contents were analysed with the confocal laser scanning microscope. The following results were obtained: 1. In group 1 and group 2, the total fluorescence of the lesion(TFL) was reduced in remineralized area compared to in demineralized area(p<0.05). 2. The total fluorescence of the lesion of remineralized area was more reduced in group 2 than in group 1(p<0.05). 3. The total fluorescence of the lesion was more reduced in group 2 than in control group(p<0.05). 4. Confocal laser scanning microscope can be used in quantitative analysis of remineralization by fluoride varnish.

  • PDF

A Study on Methods to Prevent the Spread of COVID-19 Based on Machine Learning

  • KWAK, Youngsang;KANG, Min Soo
    • Korean Journal of Artificial Intelligence
    • /
    • v.8 no.1
    • /
    • pp.7-9
    • /
    • 2020
  • In this paper, a study was conducted to find a self-diagnosis method to prevent the spread of COVID-19 based on machine learning. COVID-19 is an infectious disease caused by a newly discovered coronavirus. According to WHO(World Health Organization)'s situation report published on May 18th, 2020, COVID-19 has already affected 4,600,000 cases and 310,000 deaths globally and still increasing. The most severe problem of COVID-19 virus is that it spreads primarily through droplets of saliva or discharge from the nose when an infected person coughs or sneezes, which occurs in everyday life. And also, at this time, there are no specific vaccines or treatments for COVID-19. Because of the secure diffusion method and the absence of a vaccine, it is essential to self-diagnose or do a self-diagnosis questionnaire whenever possible. But self-diagnosing has too many questions, and ambiguous standards also take time. Therefore, in this study, using SVM(Support Vector Machine), Decision Tree and correlation analysis found two vital factors to predict the infection of the COVID-19 virus with an accuracy of 80%. Applying the result proposed in this paper, people can self-diagnose quickly to prevent COVID-19 and further prevent the spread of COVID-19.

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

Surface Characteristics of HA Coated Dental Implant Alloy by Sol-Gel Method (Sol-Gel법으로 HA코팅된 치과용 임플란트 합금의 표면특성)

  • Choe Han-Cheol;Ko Yeong-Mu
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.4
    • /
    • pp.167-173
    • /
    • 2005
  • Surface characteristics of HA(hydroxyapatite) coated dental implant alloy by Sol-Gel method were investigated using potentiostat, ICP, SEM, EDX, EPMA and surface roughness tester. Surface roughness of HA coated specimen by Sol-Gel showed higher than that of PVD coated specimen. Corrosion resistance increased in the order of $1\%$ lactic acid, artificial saliva, $0.5\%$ HCI and $0.9\%$ NaCl solution. Amount of Ca element release was higher than that of V and P in the $0.5\%$ HCI and $0.9\%$ NaCl solution.

Mechanisms Controlling Feed Intake in Large-type Goats Fed on Dry Forage

  • Sunagawa, K.;Ooshiro, T.;Murase, Y.;Hazama, R.;Nagamine, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.8
    • /
    • pp.1182-1189
    • /
    • 2007
  • An intracerebroventricular (ICV) infusion of somatostatin 1-28 (SRIF) was used as a thirst-controlling peptide antagonist to investigate whether or not thirst-controlling peptides are involved in the significant decrease in feed intake during the initial stages of feeding large-type goats on dry forage. A continuous ICV infusion of SRIF was conducted at a small dose of $4{\mu}g$ ml/h for 27 h from day 1 to day 2. Goats (n = 5) were fed roughly crushed alfalfa hay cubes for 2 h twice daily and water was given ad libitum. Feed intake was measured during ICV infusion of artificial cerebrospinal fluid (ACSF) and SRIF. The feed intake during SRIF infusion increased significantly compared to that during ACSF infusion. In comparison to the ACSF treatment, plasma osmolality during the SRIF treatment significantly decreased during the first half of the 2 h feeding period. The factor causing the decrease in plasma osmolality during the ICV infusion of SRIF was a decrease in plasma Na, K, Cl, and Mg concentrations. In comparison to the ACSF infusion treatment, parotid saliva secretion volumes during the 2 h feeding period in the SRIF infusion treatment were significantly larger. While there was no significant difference in cumulative water intake (thirst levels) between the SRIF and the ACSF treatments upon conclusion of the 2 h feeding period, based on the plasma osmolality results it is thought that thirst level increases brought about by alfalfa hay cube feeding in the first half of the feeding period were reduced. It is thought that the somatostatin-induced increases in feed intake during the 2 h feeding period in the present experiment were caused by decreases in plasma osmolality brought about by the somatostatin infusion. As a result, it is suggested that the significant decrease in feed intake during the initial stages of feeding in large-type goats given roughly crushed alfalfa hay cubes, was due to the actions of thirst-controlling peptides.

Effects of various toothpastes on remineralization of white spot lesions

  • Jo, Su-Yeon;Chong, Hyun-Jeong;Lee, Eon-Hwa;Chang, Na-Young;Chae, Jong-Moon;Cho, Jin-Hyoung;Kim, Sang-Cheol;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.44 no.3
    • /
    • pp.113-118
    • /
    • 2014
  • Objective: The purpose of this in vitro study was to examine the effects of fluoridated, casein phosphopeptide-amorphous calcium phosphate complex (CPP-ACP)-containing, and functionalized ${\beta}$-tricalcium phosphate (fTCP)-containing toothpastes on remineralization of white spot lesions (WSLs) by using Quantitative light-induced fluorescence (QLF-D) Biluminator$^{TM}$ 2. Methods: Forty-eight premolars, extracted for orthodontic reasons from 12 patients, with artificially induced WSLs were randomly and equally assigned to four treatment groups: fluoride (1,000 ppm), CPP-ACP, fTCP (with sodium fluoride), and control (deionized water) groups. Specimens were treated twice daily for 2 weeks and stored in saliva solution (1:1 mixture of artificial and human stimulated saliva) otherwise. QLF-D Biluminator$^{TM}$ 2 was used to measure changes in fluorescence, indicating alterations in the mineral contents of the WSLs, immediately before and after the 2 weeks of treatment. Results: Fluorescence greatly increased in the fTCP and CPP-ACP groups compared with the fluoride and control groups, which did not show significant differences. Conclusions: fTCP- and CPP-ACP-containing toothpastes seem to be more effective in reducing WSLs than 1,000-ppm fluoride-containing toothpastes.

EROSION OF TOOTH ENAMEL BY ACIDIC DRINKS AND REMINERALIZATION BY ARTIFICIAL SALIVA (산성 음료에 의한 법랑질의 침식과 인공타액에 의한 재광화)

  • Ahn, Ho-Young;Lee, Kwang-Hee;Kim, Dae-Eup
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 2002
  • The purpose of study was to assess the influence of acidic drinks on the erosion of tooth enamel and the effect of fluoridated saliva on the remineralization. Twenty five drinks were sampled. The erosive potential and remineralizing effect were measured by the tooth surface microhardness test. The pH of most drinks were below pH 5.5. Reduction rates of enamel surface hardness by the flavored carbonated drink were 16.90%, 25.11%, 35.10%, and 41.62% after 5, 10, 30, and 60 minutes of demineralization, and recovery rates by remineralizaing solution were 61.52%, 67.96%, 72.13% and 75.93% after 1, 24, 48, and 72 hours of remineralization, respectively. The results suggest that the most drinks in the markets have the potential to erode the teeth and that erosion occurs fast but remineralization proceeds slowly.

  • PDF