• 제목/요약/키워드: artificial saliva

검색결과 156건 처리시간 0.026초

Effects of a new desensitizing paste containing 8% arginine and calcium carbonate on the shear bond strength of orthodontic brackets

  • Yagci, Ahmet;Uysal, Tancan;Akinci, Hatice;Uysal, Banu
    • 대한치과교정학회지
    • /
    • 제41권2호
    • /
    • pp.121-126
    • /
    • 2011
  • Objective: The purpose of this study was to evaluate shear bond strength (SBS) and failure site location of brackets bonded to enamel with or without desensitizer application. Methods: Sixty-six freshly extracted human premolar teeth were randomly divided into 3 groups of 22. Group 1 served as the control. Desensitizer was applied to the remaining teeth at two time intervals (Group 2, bonded immediately after Pro-$Relief^{TM}$ (Colgate-Palmolive Co., New York, NY, USA) application and Group 3, bonded 30 days after Pro-$Relief^{TM}$ application with the teeth stored in artificial saliva during the 30 days). Orthodontic brackets were bonded with a light cure composite resin and cured with a halogen light. After bonding, the SBS of the brackets was tested using a universal testing device. Adhesive remnant index (ARI) scores were determined after the brackets failed. Data were analyzed with analysis of variance, Tukey's HSD, and G tests. Results: The SBS was significantly lower in Group 2 than in Groups 1 (p = 0.024) and 3 (p = 0.017). Groups 1 and Group 3 did not differ (p = 0.991). ARI scores did not differ significantly among groups. Conclusions: The Pro-$Relief^{TM}$ desensitizer agent applied immediately before bonding significantly reduces bond strength, but the SBS values still exceed the minimum 5.9 - 7.8 MPa required for adequate clinical performance. Immersing the teeth in artificial saliva for 30 days after applying the Pro-$Relief^{TM}$ desensitizer agent and before bonding increased the SBS to control levels.

Does the time interval after bleaching influence the adhesion of orthodontic brackets?

  • Nascimento, Glaucia Cristina Rodrigues;Miranda, Cyndi Albuquerque De;Machado, Sissy Maria Mendes;Brandao, Gustavo Antonio Martins;Almeida, Haroldo Amorim De;Silva, Cecy Martins
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.242-247
    • /
    • 2013
  • Objective: To test the null hypothesis that no difference exists between the effects of at-home bleaching and in-office bleaching on shear bond strength (SBS) with bracket bonding at 4 different time intervals after dental bleaching. Methods: Ninety extracted human premolars were randomly divided into 9 groups (n = 10) according to the bleaching methods used (at-home bleaching and in-office bleaching) and the storage time in artificial saliva (30 min, 1 day, 2 weeks, and 3 weeks before bonding). The control group was stored in artificial saliva for 7 days. Brackets were bonded with the Transbond XT adhesive system, and SBS testing was performed. The adhesive remnant index (ARI) was used to assess the amount of resin remaining on the enamel surfaces after debonding. The SBS data were analyzed by analysis of variance (ANOVA) and the Tukey test. For the ARI, the Kruskal-Wallis test was performed. Significance for all statistical tests was predetermined to be p < 0.05. Results: The SBS of the unbleached group was significantly higher (p < 0.05) than that of the bleached groups (except for the group bonded 30 min after at-home bleaching). Conclusions: The null hypothesis was not totally rejected. All bleaching groups tested had decreased SBS of the brackets to the enamel, except for the group bonded 30 min after at-home bleaching. The SBS returned to values close to those of the unbleached enamel within 3 weeks following bleaching.

Significance of Hypovolemia in Feed Intake Control of Goats Fed on Dry Feed

  • Sunagawa, Katsunori;Prasetiyono, Bambang W.H.E.;Shinjo, Akihisa
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권9호
    • /
    • pp.1267-1271
    • /
    • 2001
  • The objective of this study was to examine the significance of feeding induced hypovolemia (decrease in plasma volume) in controlling the feed intake of goats fed on dry feed. In order to alleviate hypovolemia with feeding, a 2 h intravenous infusion (16-18 ml/min) of artificial saliva or mannitol solution was begun 1 h prior to feeding and continued until 1h after the start of the 2 h feeding period. In comparison with no infusion (NI), cumulative feed intake was increased by 41% with artificial saliva infusion (ASI) and by 45% with mannitol infusion (MI) by the completion of the 2 h feeding period. Both infusion treatments (ASI and MI) were significantly different (p<0.05) from the NI treatment in terms of the cumulative feed intake. The cumulative feed intake between the ASI and MI treatments was not significantly different (p>0.05). No infusion treatment (NI) had the lowest cumulative feed intake (929 g DM), whereas MI had the highest (1345 g DM), after completion of the 2 h feeding period. Generally, infusion treatments also increased the rate of eating at all time points after feeding was commenced. Following the first 30 mins of feeding, the rate of eating decreased sharply, and subsequently declined gradually in all treatments. Compared to the NI, both ASI and MI significantly (p<0.05) decreased thirst level (water intake for 30 mins after the completion of the 2 h feeding period) by approximately 13%. However, the thirst level caused by ASI and MI was not significantly different (p>0.05). Both ASI and MI decreased the plasma concentrations of osmolality and total protein, and hematocrit at 1 h after infusion. The results suggested that the thirst sensation in the brain could be produced by feeding induced hypovolemia. Moreover, the results indicate that hypovolemia is one of the factors controlling the feed intake of goats fed on dry feed.

열처리한 교정용 호선의 기계적 성질과 금속유리에 대한 연구 (THE EFFECTS OF HEAT TREATMENT ON MECHANICAL PROPERTIES AND METAL RELEASE FROM HEAT-TREATED ORTHODONTIC ARCHWIRES)

  • 최철민;이병태
    • 대한치과교정학회지
    • /
    • 제20권2호
    • /
    • pp.381-390
    • /
    • 1990
  • The purpose of this study was to evaluate the effects of heat treatment on mechanical properties in $0.016^{{\prime}{\prime}}{\times}0.022^{{\prime}{\prime}}$ blue Elgiloy wires and to measure the amounts of nickel and chromium released from the wires in artificial saliva. Ultimate tensile strength, yield strength and elongation were measured with universal testing machine (Instron). and the amounts of nickel and chromium released from the sample were measured with atomic absorption spectrophotometer after one week immersion in the artificial saliva. Ultimate tensile strength and yield strength were progressively increased below $1000^{\circ}F$, but elongation was decreased. And the results were reversed above $1100^{\circ}F$. After heat treatment of the sample for 9 minutes at $1000^{\circ}F$, the maximum tensile strength and yield strength were $213.6kg/mm^2$, $140.1kg/mm^2$, respectively. Both tensile strength and yield strength were decreased progressively above $1100^{\circ}F$. Elongation was appeared the minimum value (8.6%) after heat treatment for 9 minutes and 12 minutes at $1000^{\circ}F$. There was a pronounced increase in nickel and chromium liberation with increasing time and temperature. The maximum amounts of nickel and chromium released form the sample were $4.947{\mu}m/cm^2$, $3.088{\mu}g/cm^2$, respectively after heat treatment for 12 minutes at $1300^{\circ}F$. Heat treatment is applied to orthodontic wires, especially cobalt-chromium alloys, for the purpose of stress-relievning and hardening. When the heat-treatment of orthodontic wires, the heating procedure should be well controlled in order to have no effect on corrosion resistance and mechanical properties.

  • PDF

표백된 법랑질의 표면처리방법에 따른 복합레진과의 전단결합강도에 관한연구 (A STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN ACCORDING TO THE SURFACE TREATMENT OF THE BLAEACHED ENAMEL)

  • 김은희;조영곤;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.351-361
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength of the composite resin bonded on the bleached enamel surface according to its surface treatment. 90 extracted human premolars were divided into six groups. : enamel unbleached (control group) and enamel bleached with 15% carbamide peroxide for 2 weeks (experimental groups: 1, 2, 3, 4 and 5). The surface of bleached enamel in all experimental groups was treated by following manners. Experimental group 1 : catalase immersion for 3 mimutes. Experimental group 2 : catalase immersion for 15 mimutes. Experimental group 3 : artificial saliva immersion for 1 hour. Experimental group 4 : artificial saliva immersion for 48 hours. Experimental group 5: surface reduction of the bleached enamel about 0.5mm-1mm with superfine diamond bur. Composite resin molds(3mm height, 3mm diameter) were bonded to the untreated enamel and treated. The shear bond strengths of composite resin bonded to enamel of each specimen were tested with universal testing machine at a crosshead speed of 5mm/min and 500Kg in full scale and analyzed statistically. The following results were obtained : 1. Control group had the highest shear bond strength with $19.92{\pm}5.14$ MPa and experimental group 5 had the lowest shear bond strength with $11.15{\pm}4.23$ MPa. 2. Control group showed significant differences in shear bond strength with experimental group 1(P<0.05). 3. Control group showed significant differences in shear bond strength with experimental group 5(P<0.05). 4. Experimental group 4 showed significant differences in shear bond strength with experimental group 5(P<0.05). 5. Experimental group 3 showed no significant differences in shear bond strength with experimental group 4(P<0.05).

  • PDF

치약 종류에 따른 유치의 표면 변화 (Change in surface of primary tooth using different type of toothpaste)

  • 최정옥;남설희
    • 한국치위생학회지
    • /
    • 제14권2호
    • /
    • pp.281-286
    • /
    • 2014
  • Objectives : The aim of this study is to evaluate the surface changes of enamel specimen, tooth structure by toothpastes in child and adult. Methods : Experimental teeth were collected from extracted human primary teeth. 120 enamel specimens were prepared by cutting the teeth into $2{\times}3{\times}2mm$ blocks using diamond saw and the specimens were assigned to 3 groups. Group 1 was used as control with no treatment. Group 2 was treated with child toothpaste and Group 3 was treated with adult toothpaste on primary enamel surface for 3 minutes daily over 4 weeks. The specimens were immersed into individual container having artificial saliva and the artificial saliva was changed every day. The electron probe micro analyzer(EPMA) provided weight percent(wt%) of calcium(Ca) and phosphorous(P) on enamel surface. The morphology was analyzed by scanning electron microscopy(SEM). Data were analyzed by one-way analysis of variance(ANOVA) and Tukey's test post-hoc test using SPSS(Version 20, SPSS Inc., Chicago, USA). Level of significance was set at 0.05. Results : The surface changes of the primary teeth revealed a significant difference during 4 weeks. Calcium(Ca) and phosphorous(P) levels were found the weight percent difference and a rough enamel surface was seen on SEM after adult toothpaste application. Conclusions : The changes in Ca and P and the morphological surface were affected by the primary tooth treated with adult toothpaste. Enamel surface showed significant differences during 4 weeks.

지르코니아/알루미나 복합체의 In-vitro Hertzian 피로거동 (In-vitro Hertzian Fatigue Behavior of Zirconia/Alumina Composites)

  • 이득용;박일석;김대준;이세종
    • 한국세라믹학회지
    • /
    • 제41권1호
    • /
    • pp.69-75
    • /
    • 2004
  • 인공치아용 3Y-TZP와 (Y,Nb)-TZP/$Al_2O_3$ 복합체를 유사 구강분위기인 인공타액 하에서 500-3000N의 하중 조건으로 $10^6$ 횟수까지 헤르찌안 반복하중 피로특성을 조사하였다. 500N의 하중에서 $5{\times}10^5$까지 반복피로 실험결과, 강도 저하 및 균열 현상은 관찰되지 않았다. 피로특성은 SY-TZP가 (T,Nb)-TZP/$Al_2O_3$ 복합체보다 상전이에 의한 응역회복 때문에 우수하였다. 하중값이 증가함에 따라 링 균열에서 방사상 균열로 전이되었을 때 급격한 강도 저하 현상이 발생하였다. 강도 저하 현상은 유사 구강 분위기하에서 반복 하중 접촉 시 발생한 균열을 통해 침투한 인공타액의 화학적 침식으로 더욱 가속화 되었다.

5% 불화나트륨을 함유한 고분자 접착필름의 법랑질 재광화효과 (Effect of Polymer Adhesive Film Supplemented 5% NaF on Enamel Remineralization)

  • 지명관;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제41권3호
    • /
    • pp.218-224
    • /
    • 2014
  • 이 논문은 법랑질의 표면미세경도와 QLF의 ${\Delta}F$ 값의 변화를 분석하여 5% 불화나트륨을 함유한 고분자 접착 테잎(NaF-PVA)이 법랑질의 재광화에 미치는 영향을 평가하고자하였다. 시편을 탈회한 후 표면미세경도가 평균 50-100 KHN의 범위를 갖고 QLF의 ${\Delta}F$ 값이 -25에서 -15 범위를 갖는 60개의 시편들을 4그룹으로 나누었다 : 그룹1(대조군), 그룹2(NaF-PVA), 그룹3(불소바니쉬, FluoroDose$^{(R)}$ varnish), 그룹4(Casein phosphopeptide-amorphous calcium phosphate, Tooth mousse plus$^{TM}$). 시편들에 각 제제들을 적용하고 인공타액(artificial saliva)에 담근 후 표면미세경도계와 정량 광 형광기를 이용하여 재광화율을 측정하였다. 그 결과 불소를 함유한 고분자 접착 테잎(NaF-PVA)은 그룹1과 4보다 뛰어나며 그룹3과 견줄만한 재광화 효과를 나타냈다 (p<0.05).

Effects of different surface treatments on the shear bond strength of veneering ceramic materials to zirconia

  • Abdullah, Adil Othman;Hui, Yu;Sun, Xudong;Pollington, Sarah;Muhammed, Fenik Kaml;Liu, Yi
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.65-74
    • /
    • 2019
  • PURPOSE. To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS. 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS. Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions ($1.05{\pm}0.24{\mu}m$, $1.30{\pm}0.21{\mu}m$) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions ($30.97{\pm}3.12MPa$, $29.09{\pm}4.17MPa$), while group SLV recorded the lowest ($23.96{\pm}3.60MPa$, $22.95{\pm}3.68Mpa$) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION. GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns.

Oxide Nanolayers Grown on New Ternary Ti Based Alloy Surface by Galvanic Anodizing-Characteristics and Anticorrosive Properties

  • Calderon Moreno, J.M.;Drob, P.;Vasilescu, C.;Drob, S.I.;Popa, M.;Vasilescu, E.
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.257-264
    • /
    • 2017
  • Film of new Ti-15Zr-5Nb alloy formed during galvanic anodizing in orthophosphoric acid solution was characterized by optical microscope, scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), and Raman micro-spectroscopy. Its anticorrosive properties were determined by electrochemical techniques. The film had a layer with nanotube-like porosity with diameters in 500-1000 nm range. The nano layer contained significant amounts of P and O as well as alloying element. Additionally, Raman micro-spectroscopy identified oxygen as oxygen ion in $TiO_2$ anatase and phosphorous as $P_2O_7{^{4-}}$ ion in phosphotitanate compound. All potentiodynamic polarization curves in artificial Carter-Brugirard saliva with pH values (pH= 3.96, 7.84, and 9.11) depending on the addition of 0.05M NaF revealed nobler behavior of anodized alloy and higher polarization resistance indicating the film is thicker and more compact nanolayer. Lower corrosion rates of the anodized alloy reduced toxicity due to less released ions into saliva. Bigger curvature radii in Nyquist plot and higher phase angle in Bode plot for the anodized alloy ascertain a thicker, more protective, insulating nanolayer existing on the anodized alloy. Additionally, ESI results indicate anodized film consists of an inner, compact, barrier, layer and an outer, less protective, porous layer.