• 제목/요약/키워드: artificial resin teeth

검색결과 69건 처리시간 0.025초

Utility of intraoral scanner imaging for dental plaque detection

  • Chihiro Yoshiga;Kazuya Doi;Hiroshi Oue;Reiko Kobatake;Maiko Kawagoe;Hanako Umehara;Kazuhiro Tsuga
    • Imaging Science in Dentistry
    • /
    • 제54권1호
    • /
    • pp.43-48
    • /
    • 2024
  • Purpose: Oral hygiene, maintained through plaque control, helps prevent periodontal disease and dental caries. This study was conducted to examine the accuracy of plaque detection with an intraoral scanner(IOS) compared to images captured with an optical camera. Materials and Methods: To examine the effect of color tone, artificial tooth resin samples were stained red, blue, and green, after which images were acquired with a digital single-lens reflex (DSLR) camera and an IOS device. Stained surface ratios were then determined and compared. Additionally, the deviation rate of the IOS relative to the DSLR camera was computed for each color. In the clinical study, following plaque staining with red disclosing solution, the staining was captured by the DSLR and IOS devices, and the stained area on each image was measured. Results: The stained surface ratios did not differ significantly between DSLR and IOS images for any color group. Additionally, the deviation rate did not vary significantly across colors. In the clinical test, the stained plaque appeared slightly lighter in color, and the delineation of the stained areas less distinct, on the IOS compared to the DSLR images. However, the stained surface ratio was significantly higher in the IOS than in the DSLR group. Conclusion: When employing IOS with dental plaque staining, the impact of color was minimal, suggesting that the traditional red stain remains suitable for plaque detection. IOS images appeared relatively blurred and enlarged relative to the true state of the teeth, due to inferior sharpness compared to camera images.

CPP-ACP 함유 크림과 불소가 초기 인공우식 법랑질에 미치는 재광화 효과에 대한 비교 연구 (COMPARATIVE STUDY OF THE REMINERALIZATION EFFECTS USING CPP-ACP AND FLUORIDE ON THE ARTIFICIAL ENAMEL LESION)

  • 김기백;최남기;김선미;양규호
    • 대한소아치과학회지
    • /
    • 제36권1호
    • /
    • pp.38-45
    • /
    • 2009
  • 본 연구는 상품화된 10% CPP-ACP 크림 (Tooth mousse, GC Co., Japan)이 0.05 % NaF 불소 용액 매일 양치법을 대체할 수 있는지 알아보기 위하여, 인공 탈회 병소를 가진 우치 법랑질에 대해 10일간 위 두 가지 방법 단독 혹은 복합 사용의 재광화 효과를 비교하였다. 0.1% thymol 용액에 냉장 보관한 소의 치아를 교정용 레진 (Orthodotic resin, Dentsply international Inc., USA)에매몰한 후 탈회 용액에 96시간 보관하였고, 총 60개의 시편을 5개의 군으로 나누었다; 비처치군 (1군), 0.05% NaF 용액 1분 (2군), Tooth mousse 3분 (3군), 0.05% NaF 용액 1분 처리 후 Tooth mousse 3분 (4군), Tooth mousse 3분 처리 후 0.05% NaF 용액 1분(5군). 재광화 정도는 10일간의 시편 처리 전 후의 Vickers hardness number를 측정하여 비교하였으며, 연구 결과는 다음과 같다. 1. 각 군에서 시편 처리 전후의 표면경도를 paired t-test를 이용하여 비교분석한 결과, 3, 4, 5 군에서만 유의할만한 표면 경도 증가가 나타났다(P < 0.05). 2. 각 군별로 평균 표면 경도 증가량은 5 > 4 > 3 > 2 > 1 군 순이었고, 각 군의 표면경도 증가량을 one-way ANOVA test로 비교분석한 후 Duncan test로 사후 검정한 결과, 4, 5 군은 1, 2, 3 군과 유의할만한 표면경도 증가를 보였으며 (P < 0.05), 다른 군들 간에는 유의할만한 차이를 보이지 않았다. 3. Tooth mousse를 우치에 10일간 적용시킨 결과 0.05% NaF 용액보다 더 많은 표면경도 변화량을 나타냈지만, 통계학적으로 유의할만한 차이는 없었다. 이상의 결과에서 Tooth mousse 사용은 불소 양치가 용이하지 않은 환자들에게 양호한 대체 방안이 될 것으로 사료되며, 또한 불소 적용시 Tooth mousse를 복합 사용하는 것이 추천될 수 있으리라 사료된다.

  • PDF

BIOMECHANICS OF ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES UNDER UNILATERAL LOADING

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Jeong-Taek;Roh, Hyun-Ki;Kim, Hyo-Jin;Lee, Seok-Hyung;Lee, Joo-Hee
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.753-759
    • /
    • 2007
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge. Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm dose to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. Results. The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load in increased from 30N to 100N (p<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 100N loading in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.

QLF(Quantitative light-induced fluorescence)를 이용한 글라스 아이오노머 수복물의 인접면 우식 재광화 효과에 관한 연구 (REMINERALIZATION EFFECT OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: IN VITRO STUDY USING QLF)

  • 이혁상;현홍근;장기택
    • 대한소아치과학회지
    • /
    • 제38권3호
    • /
    • pp.244-249
    • /
    • 2011
  • 글라스 아이오노머 시멘트는 초기 우식 치질에 재광화 효과가 있다고 알려져 있다. 본 연구에서는 시판되고 있는 세 가지 종류의 글라스 아이오노머 시멘트(Fuji IX $GP^{TM}$, $Vitremer^{TM}$, $F2000^{TM}$)를 실험군으로, 복합 레진(Filtek $Z250^{TM}$)을 대조군으로 사용하여 3개월간 인접면 우식증에 대한 재광화 효과를 시편의 파괴 없이 1개월 간격으로 QLF로 시편의 상을 얻고, 이렇게 얻은 상의 무기질 소실량(${\Delta}Q$)을 측정하여 ${\Delta}Q$의 변화량을 계산하여 시편의 재광화 정도를 평가하였다. 인접면 수복물은 인공 우식 병소가 있는 치아 시편과 수복재료(세 가지 글라스 아이오노머 및 복합 레진)를 접촉시켜 재현하였고, 이것을 인공 타액에 완전히 잠기도록 하여 pH 7.0, $37^{\circ}C$를 유지하였다. 치아 시편들은 실험 시작 후 30, 60, 90일 뒤에 꺼내어 QLF로 촬영하였다. 얻어진 영상을 QLF를 이용하여 시편 각각의 무기질 소실량(${\Delta}Q$)을 측정하였고, ${\Delta}Q$의 변화량(${\Delta}{\Delta}Q$), 즉 무기질 소실 변화량을 계산하여 얻어진 값을 ANOVA로 분석하고, Dunnett C multiple comparison test로 사후 검정을 시행하여 다음과 같은 결과를 얻었다. 1. 모든 군에서 병소의 무기질 소실량(${\Delta}Q$)이 증가하였다. 2. 무기질 소실량(${\Delta}Q$)의 변화량인 무기실 소실 변화량(${\Delta}{\Delta}Q$)은, 1 개월 후에는 글라스 아이오노머 시멘트가 복합레진에 비해 유의하게 컸으며(p<0.05), 글라스 아이오노머 중에서는 Fuji IX $GP^{TM}$$Vitremer^{TM}$, $F2000^{TM}$에 비해 유의하게 컸다(p<0.05). 2 개월 후에는 Fuji IX $GP^{TM}$가 나머지 군에 비해 ${\Delta}{\Delta}Q$가 유의하게 컸으며(p<0.05), 3 개월 후에는 모든 군간에 ${\Delta}{\Delta}Q$의 유의한 차이가 없었다. 3. 세 가지 글라스 아이오노머 시멘트에서 무기실 소실 변화량(${\Delta}{\Delta}Q$), 즉 재광화 정도는 시간이 지날수록 점차 감소하였다. 4. 대조군인 복합 레진 군에서도 무기실 소실 변화량(${\Delta}{\Delta}Q$)은 증가하였다.

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

Fuji VII 글래스 아이오노머 시멘트의 재광화 효과 (REMINERALIZATION EFFECT OF FUJI VII GLASS IONOMER CEMENT)

  • 김영진;이주현;서현우;박호원
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.653-660
    • /
    • 2006
  • Fuji VII은 제 1, 2대구치의 조기보호를 목적으로 소개되었으며 기존의 글래스 아이오노머 시멘트보다 많은 양의 불소를 유리하면서도 점도가 낮아 흐름성이 우수하고 부가적인 산부식 과정이 필요 없는 특징 때문에 치은판개가 일부 덮인 제 1, 2대구치의 교합면이나 일부만 노출된 대구치 협면구의 우식 예방과 재광화에 유용하다고 하였다. 본 연구의 목적은 Fuji VII의 재광화 효과를 알아보고 기존의 글래스 아이오노머 시멘트, 레진 강화형 글래스 아이오노머 시멘트, 콤포머와 복합레진의 재광화 효과를 비교하고자 하였다. 이에 인공적으로 형성한 우식을 가진 42개의 치아에 Fuji VII, Fuji II, Fuji II LC improved F2000, $Filtek^{TM}$ Z250의 재료를 충전하고 편광현미경 상에서 충전 직후와 4주 후 탈회 면적을 측정하였으며 두 면적의 차이를 비교하여 다음의 결과를 얻었다. 1. 재광화 정도는 Fuji VII, Fuji II, Fuji II LC improved, F2000, 대조군, $Filtek^{TM}$ Z250 순으로 크게 나타났으며, 글래스 아이오노머 계통의 Fuji VII, Fuji II, Fuji II LC improved에서 F2000, $Filtek^{TM}$ Z250, 대조군에 비해 유의한 재광화가 나타났다(p<0.05). 2. Fuji VII과 Fuji II Fuji II LC improved 간에는 유의한 재광화 정도의 차이는 관찰되지 않았다(p>0.05).

  • PDF

파손된 치면열구전색제의 수리 방법에 따른 미세누출 비교 (COMPARISON OF MICROLEAKAGE IN SEALANT REPAIRED WITH DIFFERENT SURFACE TREATMENT)

  • 강명봉;현홍근;김영재;김정욱;장기택;이상훈;한세현;김종철
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.204-214
    • /
    • 2007
  • 치면열구전색은 수 십년간 교합면 우식의 예방에 가장 효과적인 방법 중 한가지로 알려져 왔다. 하지만 치면열구전색제의 마모와 파절 때문에 치면열구전색제의 재시술 또는 수리를 필요로 하게 되었다. 본 연구의 목적은 파손된 치면열구전색제를 수리할 때 치질과 잔여 전색제의 표면처리 방법에 따른 미세누출 차이를 알아보고자 하는 것이다. 120개의 영구 대구치에 치면열구전색제를 적용하고 인위적인 파손을 만든 뒤 인공타액에 4주동안 보관하였다. 4주 후 근심 또는 원심의 치면열구전색제가 완전히 파손 양상을 나타내는 치아 60개를 선택하여 각각 15개씩 4개 군으로 나누어 실험에 사용하였다. 각 군을 산부식만 시행한 경우(1군), air-abrasion만 시행한 경우(2군), 산부식 후 결합제를 적용한 경우(3군), air-abrasion 후 결합제를 적용한 경우(4군)로 나눠 각각의 치아를 표면처리한 후 치면열구전색제를 도포하였다. 고온$(55^{\circ}C)$과 저온$(5^{\circ}C)$에서 각각 30초씩 500회의 열순환을 시행한 뒤 미세누출도를 검사하여 다음과 같은 결과를 얻었다. 1. 치면열구전색제/치면열구전색제 경계면에서 미세누출도는 결합제 사용 유무에 관계없이 air-abrasion을 처리한 2군, 4군에서 산부식을 사용한 1군, 3군보다 낮은 값을 보였고(p<0.05) 1군과 2군, 3군과 4군 사이에는 통계적 유의차가 없었다(p>0.05). 2. 치면열구전색제/치아 경계면에서 미세누출도는 결합제를 사용한 3군, 4군에서 결합제를 사용하지 않은 1군, 2군보다 낮은 값을 보였고(p<0.05) 산부식을 사용한 1, 3군과 air-abrasion을 사용한 2, 4군 사이에는 통계적 유의차가 없었다(p>0.05). 3. SEM 상에서 치면열구전색제를 산부식 처리하였을 때 표면거칠기의 증가가 적었으나 air-abrasion 하였을 경우 표면거칠기가 현저하게 증가하는 것을 관찰하였다.

  • PDF

인접면 초기 우식 병소의 깊이에 따른 therapeutic sealing의 유효성 평가 (EVALUATION OF THE EFFECTIVENESS OF THERAPEUTIC SEALING ACCORDING TO THE LESION DEPTHS OF PROXIMAL EARLY CARIES)

  • 이금랑;안명기;정태성;김신
    • 대한소아치과학회지
    • /
    • 제36권3호
    • /
    • pp.394-403
    • /
    • 2009
  • 인접면 초기 우식병소에 대하여 레진 접착제를 도포하는 최소 침습적 개념의 therapeutic sealing은 치질 삭제가 불필요하다는 점에서 의미있는 술식으로 인정된다. 그러나 이 방법이 초기 우식병소의 법랑질 내 침투 깊이와 무관하게 여전히 유효할 것인지에 대해 의문이 들어 이번 연구는 그 유효성을 평가해 보기 위해 시도되었다. 인접면에 초기 우식병소를 보이는 발거된 소구치 21개를 대상으로 하고, micro-CT 촬영을 통해 병소의 깊이에 따라 분류하였다. 전체 시편을 병소가 법랑질 외층에 국한된 시편의 표면 절반에 접착제를 도포한 1군과 하지 않은 2군, 병소가 법랑질 내층까지 진행된 시편의 표면 절반에 접착제를 도포한 3군과 하지 않은 4군, 비와동성 초기 병소가 법랑-상아 경계까지 진행된 시편의 표면 절반에 접착제를 도포한 5군과 하지 않은 6군으로 분류하였다. 열순환 후 2주간 인공 우식을 유발하고 분류과정과 동일한 평면을 찾아 micro-CT를 촬영하고 병소의 방사선 밀도 변화를 관찰하여 다음과 같은 결과를 얻었다. 1. 인접면 초기 우식병소의 침투 깊이가 증가할수록 병소 본체의 방사선 밀도는 낮아지는 것이 관찰되었다. 2. 병소의 깊이에 무관하게, 레진 접착제를 도포한 모든 실험군에서 처리하지 않은 대조군에 비하여 인공 우식 처리 전후의 방사선 밀도 변화 가 작게 나타났다(p<0.05). 3. 병소가 법랑-상아 경계에 도달한 5군에서도 레진 접착제를 도포하고 인공 우식 처리시, 실험 전후의 유의한 방사선 밀도 변화가 나타나지 않았다(p<0.05).

  • PDF

Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향 (The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive)

  • 김유신;이형순;이현정;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제34권5호
    • /
    • pp.439-447
    • /
    • 2004
  • 이 연구는 self-etching primer와 adhesive를 사용하여 법랑질 표면에 교정용 브라켓을 접착할 때 수분과 타액, 그리고 혈액에 의한 오염이 브라켓의 전단결합강도에 어떤 영향을 미치는지 알아보고자 시행되었다. 96개의 발거된 치아를 4개의 군으로 나누어서 self-etching primer와 adhesive를 사용하여 다음의 4가지 방법에 따라 교정용 브라켓을 접착하였다 첫 번째 군은 치면을 건조시킨 상태에서 부착하였고 두 번째, 세 번째, 네 번째 군은 각각 증류수, 인공타액. 혈액을 적용한 후 브라켓을 접착하였다 각 시편의 전단결합강도를 측정하였고 debonding 후에 브라켓과 치아 표면은 stereomicroscope을 사용하여 관찰하였다. 각 군에서 4개씩의 시편을 선택하여 표면처리된 법랑질 표면과 접착계면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 건조군과 증류수군의 전단결합강도는 각각 $15.22{\pm}2.86$ MPa과 $160.20{\pm}3.85MPa$로 혈액군의 전단결합강도$(12.50{\pm}2.94MPa)$보다 높았다.(P<0.05). 건조군과 증류수군, 그리고 인공타액군간에는 전단결합강도에 통계적 차이가 없었다(p>0.05). 혈액군은 다른군에 비해서 debonding 후 법랑질 표면에 잔류한 레진의 양이 더 적었다.(p<0.06). self-etching primer로 처리된 치면의 주사전자현미경 소견에서 건조군과 증류수군의 치면에서는 인공타액군과 혈액군에 비해서 더욱 뚜렷한 산부식 구조를 볼 수 있었다. 이상의 결과로서 self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 수분이나 타액의 오염은 결합력에 거의 영향을 미치지 않음을 알 수 있으며. 혈액으로 오염시에는 결합력에 영향을 미치지만. 임상적으로 유용한 최소 결합강도(5.9-7.8 MPa) 이상을 보이고 있음을 알 수 있었다.