• Title/Summary/Keyword: arthroscopic surgery

Search Result 856, Processing Time 0.02 seconds

Ultrasonographic Utility for Arthroscopic Examination of Knee (슬관절 관절경 검사 시 초음파 검사의 유용성)

  • Byun, Ki-Yong;Rhee, Kwang-Jin;Kim, Kyung-Cheon;Kim, Dong-Kyu;Kim, Bo-Kun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • Purpose: To evaluate the relationship between the real pathology & abnormal finding found by ultrasonography. Without an MRI test being done beforehand, an arthroscopy is done after an ultrasonography to show abnormal lesions during a knee abnormality. Materials and Methods: The subjects were 42 patients out of 49 cases, excluding those with rheumatoid arthritis, septic arthritis and patients suspected with a ligament tear, which were examined by ultrasonography alone before receiving a knee arthroscopy in our hospital from July 2007 to July 2008. In every case, a physical examination, simple X-ray and knee ultrasonography was done. An arthroscopy was performed when there was ultrasonographic abnormal finding. Before the procedure, a MRI test was not performed and when abnormal findings were found by an arthroscopy, an appropriate surgery was done. Results: During the ultrasonographic examination, there were various sized effusions in the suprapatellar pouch. Also, in addition there were eleven cases of medial meniscus abnormalities, sixteen cases of lateral meniscus abnormalities, and two cases of cystic lesions. Throughout the arthroscopic examination, there were 14 cases of medial meniscus abnormalities, 20 cases of lateral meniscus abnormalities, 15 cases of cartilage damages, 9 cases of medial pathologic plica, 2 cases of intra-articular loose bodies, 5 cases of chondromalacia, 2 cases of cyst, and 2 cases of synovitis. When an effusion abnormality was found by the ultrasonography in a suprapatellar pouch, there was a 100% probability of knee pathology. When a medial meniscus abnormality was found with an ultrasonography, there was a 90.9% probability of a real pathology. When a lateral meniscus abnormality was found there was 81.2% probability of a real pathology. Ultrasonography was 100% accurate when it came to cystic lesions. Conclusion: Knee ultrasonography performed before an arthroscopy seems to be a very useful examination method when suspecting intra-articular lesions.

  • PDF

Is the UU Stitch Really Alternative to Modified MA (Mason-Allen) Stitch for Rotator Cuff Repair? - Biomechanical Comparative Study of UU to Modified MA Stitch - (회전근 개 파열의 봉합에서 UU 봉합법은 변형된 MA(Mason-Allen) 봉합법을 대치할 수 있는가? - UU 봉합법과 변형된 MA 봉합법의 생역학적 비교-)

  • Friedman, Darren J;Ko, Sang-Hun;Park, Ki-Bong;Jun, Hyung-Min;Kim, Tae-Won;Lim, Hyun-Woo;Yum, Young-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • Purpose: In arthroscopic rotator cuff repairs there are generally weak link in tendon suture interface, arthroscopic rotator cuff repairs can have higher retear rates than open repairs. The purpose of this study was to compare the strength of UU (Ulsan University) suture than open modified MA (Mason-Allen) suture when suture anchored into bone. Materials and Methods: The human supraspinatus tendons were harvested from the shoulder of the cadaver and split in 2 times, producing four tendons per one shoulder, for a total of 24 specimens. Two suture configurations (UU, MA) were randomized and checked on each set of tendons. Specimens were cyclically loaded under force control between 5 and 30 N at 0.25 Hz for fifty cycles. Each specimen was loaded to failure under displacement control at 1 mm/sec. Cyclic elongation, peak to peak displacement, stiffness, ultimate tensile load, mode of failure were checked. Results: No significant difference was found between two suture configuration with respect to peak to peak displacement, cyclic elongation, and stiffness. With regard to ultimate failure load, there were no significant difference statistically between the UU suture and modified MA suture (109.4 N, 110.6 N). The most common mode of failure between both sutures was suture pull-out through the tendon. Conclusion: The UU suture and modified MA suture produced similar biomechanical properties.

Treatment of Lateral Meniscus Injury (외측 반월상 연골손상의 치료)

  • Bae, Dae-Kyung;Kwon, Oh-Soo;Lim, Chan-Teak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.92-98
    • /
    • 2001
  • Purpose : To analyze the clinical results of isolated lateral meniscus injury according to discoid versus non-discoid, athletes versus non-athletes and repaired cases versus cases treated with meniscectomy. Materials and Methods : Between January 1997 and June 2000, arthroscopic lateral meniscus surgery was performed in 329 cases. We reviewed 80 cases of isolated lateral meniscus injury without associated ligament injury or other pathologic condition retrospectively. The study population was composed of 54 males and 26 females with average age of 30.2 years(range, $17\~40$ years). Average follow up period was 15 months(range, $12\~39$ months). Eighty cases were classified into three categories; discoid group versus non-discoid group, athletes versus non-athletes, repaired cases versus cases treated with meniscectomy. Clinical evaluation was performed using Lysholm knee score and Tegner activity. Results : Non-discoid group had higher incidence of longitudinal tear than discoid group. Athletes group had higher incidence of repaired cases than non-athletes group. The repaired group had better clinical result than patient treated with meniscectomy group. Conclusion : Although lateral meniscus has some special features including anatomic mobility which can cause instability after meniscectomy and technical difficulties in repairing, it is recommended repairing meniscus tear not only longitudinal but also horizontal and complex tear to obtain better clinical results.

  • PDF

Outcome in Impingement Syndrome of the Shoulder According to Presence of Stiffness (견관절 충돌 증후군 환자에서 강직 여부에 따른 치료 결과)

  • Moon, Gi-Hyuk;Lee, Jae-Wook;Yoo, Moon-Jib;Park, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.45-50
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the outcome of operative results in the impingement syndrome of the shoulder with and without the stiffness. Material and Method: Seventy-six patients who had the impingement syndrome without stiffness were evaluated, and treated with the subacromial decompression and 24 patients who had the impingement syndrome with stiffness, were treated with the subacromial decompression and the manipulation. The average follow-up period was 32 months. Result: The impingement syndrome of the shoulder with stiffness was more severe in the preoperative pain and worse in ASES score than without stiffness. The postoperative pain and ASES score improved in the both group. The satisfactory groups were 67% in the group with stiffness and 80% without stiffness. The satisfactory rate was 83% in the group with stiffness and 93% without stiffness. The satisfactory groups with diabetes were 47% in the group with stiffness and 81% without stiffness. Forward elevation, exeternal rotation at the side and internal rotation improved in both groups postoperatively and there were no statistically significant differences postoperatively External rotation was restricted statistically in the group with stiffness. Conclusion: Although patients may not regain the full range of motion, the technique of manipulation followed by arthroscopic subacromial decompression offers good pain relief and satisfactory functional recovery for the impingement syndrome with stiffness. However preoperative counseling is necessary for the impingement syndrome combined with diabetes and stiffness due to poor out come.

  • PDF

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

Technical Note of Meniscal Allograft Transplantation using Minimal Incision (최소 절개술에 의한 반월상 연골 동종이식 수술기법)

  • Min, Byoung-Hyun;Kim, Ho Sung;Jang, Dong Wok;Kang, Shin Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The current treatment of extensive meniscal injuries has resulted in numerous investigations and clinical trials to restore normal meniscal functions. A cryopreserved meniscal allograft transplantation is one of the successful methods available to restore the meniscus. All the procedures of 26 cases were performed in an minimal open fashion, though initial four cases were done with the aid of arthroscope. In all of the grafts, we used a bone bridge which was attached to meniscus for better stability and healing. Anterior cruciate ligament reconstructions were also performed simultaneously with the meniscal procedures. We attempted to minimize articular cartilage by employing so called the "Key-hole technique" for the medial meniscus transplantation. First, the meniscal cartilage bone bridge was shaped into a cylinder and a bone tunnel was made just beside the medial border of the anterior criciate ligament insertion of the recipient knee joint, and the bone bridge of the meniscal cartilage was push to press-fit. The inserted meniscal cartilage was sutured by the usually employed technique under arthroscopic control. The lateral meniscus was shaped different to the medial meniscus in that the bone bridge was semicylindrical and the bone trough was made beside the lateral border of the anterior criciate ligament insertion of the recipient knee joint. The meniscus was put into the bone trough and the leading suture was extracted anterior to the tibia and tied the knot. The inserted meniscus was sutured in the same manner as the medial meniscus transplantation. By the above described method, the authors were able to minimize the articular cartilage invasion and transplant the meniscus with relative accuracy.

  • PDF

Clinical Results after ACL Reconstruction using Tibialis Anterior Tendon Allograft and Hamstring Tendon Autograft (동종 전경골건과 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술의 결과 비교)

  • Yoon, Kyoung-Ho;Bae, Dae-Kyung;So, Dong-Hyuk;Lee, Jeong-Hwan;Kim, Jeong-Weon;Park, Soo-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.85-91
    • /
    • 2007
  • Purpose: To analyze the clinical results and second look arthroscopic findings of anterior cruciate ligament(ACL) reconstruction with a tibialis anterior tendon allograft and a hamstring tendon autograft. Materials and Methods: We reviewed the cases of athroscopic ACL reconstructions using allogenous tibialis anterior(TA) tendon and autogenous hamstring tendon done from March, 2002 to August, 2005 and followed-up more than 1 year. The 250 cases were included in this study and allogenous TA tendon was used in 150 cases and autogenous hamstring tendon in 100 cases. The mean follow-up period was 15 months and 14 months, respectively. The clinical evaluation was done by Lachman test, Pivot shift test, KT-1000 arthrometer and International Knee Documentation Committee(IKDC) knee score. Graft tension, synovial coverage were observed in cases of second look arthroscopy. Results: At final follow-up, there was no significance between the two groups in clinical examination. On second look arthroscopy, synovial coverage was better in autogenous hamstring tendon group than allogenous TA tendon group(p=0.005). But no difference was found in graft tension(p>0.05). Conclusion: There were no significant differences between the two groups in the clinical results. But autogenous hamstring tendon group had better synovial coverage than allogenous TA tendon group in second look arthroscopy.

  • PDF

Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Park, Han-Chang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.

  • PDF

Using the Arthroscopic Remplissage of Anterior Shoulder Instability with Hill-Sachs Lesion (전방 견관절 불안정성에서 Hill-sachs 병변의 관절경적 Remplissage)

  • Ko, Sang-Hun;Jung, Kwang-Hwan;Shin, Seung-Myeong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: We evaluated the minimal 1 year follow-up results (shoulder stability and the clinical and functional results) for the Remplissage technique to fill a Hill-Sachs lesion. Materials and Methods: The subjects were 12 patients who could be followed up for more than 12 months after the "Remplissage" procedures in our hospital from December 2008 to November 2009. Their mean age was 27.9 years old and the mean follow-up was 19 months. The evaluations included the ROM, the ASES score, the KSSI score, the ROWE score and postoperative MRI. Results: On the postoperative functional evaluation after an average of 16 months, the ASES score improved from 50.8 preoperatively to 78.3 postoperatively, the KSSI score improved form 44.5 preoperatively to 81.0 postoperatively and the ROWE score improved from 40.2 preoperatively to 84.3 postoperatively. After an average 14 months for all the cases, the range of movement was nearly in the normal range, which is 178.6${\pm}$18.6 (165~180) degrees for forward flexion and 49.3${\pm}$10 (43~60) degrees for external rotation. Conclusion: For recurrent shoulder instability with a large Hill-Sachs lesion, the Remplissage technique has a good outcome after more than 1 year follow-up in terms of the shoulder stability and the clinical and functional results.

Clinical and Radiographical Follow-up for Residual Displacement of Fracture Fragments after Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서 교합성 골수강 내 금속정 고정 후 잔존한 골절편 전위에 대한 임상적, 방사선학적 추시)

  • Yum, Jae-Kwang;Lim, Dong-Ju;Jung, Eui-Yub;Sohn, Su-Een
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.107-114
    • /
    • 2013
  • Purpose: This study is designed to evaluate the clinical and radiographical results for the displacement of fracture fragments after interlocking intramedullary nailing in humeral shaft fractures. Materials and Methods: We retrospectively reviewed the results of 8 cases of humeral shaft fractures that have displacements of over 10 mm and under 20 mm after interlocking intramedullary nailing between July 2004 and August 2011. The mean age was 54.1 years (range, 43 to 70 years) and there were 3 male and 5 female patients. Radiographically, the time to bony union, change of displacement and angulation of the fracture site, and degree of improvement of these two factors were measured. Clinically, the range of motion of shoulder and elbow joints, postoperative pain and complications were evaluated. Results: All cases showed complete bony union in last follow-up. The mean time to bony union was 16.1 weeks. At the last follow-up, almost all cases had normal range of motion of shoulder and elbow joints. But, one case had stiffness of shoulder joint. Therefore, arthroscopic capsular release and manipulation was performed. One case had transient shoulder pain and the other case had transient elbow pain. In the two cases, pull-out of proximal interlocking screw were noted, but they finally had bony union. Conclusion: Although considerable displacement of fracture fragments after interlocking intramedullary nailing in humeral shaft fractures was present, we had excellent radiographical and clinical outcomes. Therefore, an additional procedure, such as open reduction or another fixation for the fracture site, was not necessary.