• Title/Summary/Keyword: arterial blood pressure

Search Result 606, Processing Time 0.03 seconds

Effects of Hypovolemic Hypotension on Cardiopulmonary Functions and Acid-Base Balance (출혈성 쇼크가 심폐기능 및 산.염기평형에 미치는 영향)

  • Sou, Won-Young;Lee, Sung-Haing
    • Journal of Chest Surgery
    • /
    • v.6 no.2
    • /
    • pp.131-142
    • /
    • 1973
  • Studies of cardiopulmonary function and acid-base balance were performed on 29 dogs during control period, during oligemic hypotension and following return of blood to the animals. Intravenous morphine and local anesthesia were used. Fifteen of the 29 animals survived the complete experiment. The 14 animals that failed to survive the experimental period died between 15 to 90 minutes after the onset of bleeding. The results were as follows. 1. The heart rate increased after the onset of bleeding and failed to return to control level following reinfusion. Stroke volume decreased markedly after bleeding and failed to recover after return of blood from the reservoir. Cardiac output also decreased during oligemic hypotension and was maintained at this level after re-infusion. Total peripheral resistance decreased significantly immediately after bleeding, however it increased soon over the pre-bleeding level. Central venous pressure decreased after the onset of bleeding and remained at lower level for the rest of the experimental period. Arterial blood pressure, clown to 40-45 mmHg by acute hemorrhage, was elevated near to control level. Left ventricular work decreased tremendously during oligemic hypotension and failed to return to control level with the re-infusion of blood. Hematocrit value showed no significant decrease after bleeding and increased after re-infusion. Hemoglobin decreased after the onset of bleeding and recovered to control value after re-infusion. 2. The respiratory rate fell rapidly after bleeding from 124 to 29 and remained at this lower level for the remainder of the experiment. The tidal volume increased after bleeding and was maintained at this level for the remainder of the experiment. The respiratory minute volume showed no significant changes throughout the experimental period. Oxygen consumption fell lightly in all animals during oligemic hypotension and returned to normal levels following re-infusion. Arterial oxygen content and arterial oxygen saturation decreased following bleeding and the values returned to normal levels after the return of blood from the reservoir The arterio-venous oxygen difference increased after the onset of bleeding. It failed to return to normal values following re-infusion. Arterial $Pco_2$ decreased in all animals after the beginning of the bleeding. Partial pressure of $Co_2$ continued to fall until re-infusion, after which the values returned toward normal. Animals became acidotic. The pH fell to lower level following bleeding. Lactic acid and lactate: pyruvate ratio also increased during same period. Arterial pH and lactic acid failed to return to control value and lactate: pyruvate ratio increased more after re-infusion. Sodium bicarbonate decreased after bleeding and returned to control value following re-infusion.

  • PDF

Hemodynamic Analysis of Pig's Left Common Coronary Artery (I) (좌주간부 관상동맥에 관한 혈류역학적 분석 (I))

  • Park, Jung-Su;Chang, Ju-Hee;Moon, Su-Yeon;Shin, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1923-1929
    • /
    • 2003
  • The present study investigated the microcirculation of blood in the left common artery (LCCA). In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary conditions. In this study, the statistical distribution of blood pressure, blood flow, and blood volume in the LCCA were determined based on the anatomical branching pattern of the coronary arterial tree and the statistical data of blood vessel dimensions. Our calculations were in good agreement with the previous studies. The present results showed that the mean longitudinal pressure drop profile was function of the vessel order numbers. It was found that the normalized pressure drop was a logarithmic function of the compliance.

  • PDF

Effects of Head-down Tilt $(-6^{\circ})$ on Peripheral Blood Flow in Dogs (두부하위$(-6^{\circ})$로의 체위변동이 말초혈류에 미치는 영향)

  • Chae, E-Up;Yang, Seon-Young;Bae, Jae-Hoon;Song, Dae-Kyu
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.51-65
    • /
    • 1990
  • The purpose of the present study was to examine the hemodynamic responses, especially in arterial and skin blood flows, in conjunction with the changes of plasma catecholamine levels as an indirect marker of adrenergic tone during the early stage of head-down tilt (HDT), and to evaluate the early physiological regulatory mechanism in simulated weightlessness. Ten mongrel dogs, weighing8\;{\sim}\;14\;kg, were intravenously anesthetized with nembutal, and postural changes were performed by using the tilting table. The postural changes were performed in the following order: supine, prone, HDT $(-6^{\circ}C)$ and lastly recovery prone position. The duration of each position was 30 minutes. The measurements were made before, during and after each postural change. The arterial blood flow $({\.{Q}})$ at the left common carotid and right brachial arteries was measured by the electromagnetic flowmeter. Blood pressure (BP) was directly measured by pressure transducer in the left brachial artery. To evaluate the peripheral blood flow, skin blood flow $({\.{Q}})$ was calculated by the percent changes of photoelectric pulse amplitude on the forepaw, and skin temperature was recorded. The peripheral vascular resistance (PR) was calculated by dividing respective mean BP values by ${\.{Q}}$ of both sides of common carotid and brachial arteries. Heart rate (HR), respiratory rate (f) and PH, $Po_{2},\;Pco_{2}$ and hematocrit of arterial and venous blood were also measured. The concentration of plasma epinephrine and norepinephrine was measured by radioenzymatic method. The results are summarized as follows: Tilting to head-down position from prone position, HR was initially increased (p<0.05) and BP was not significantly changed. While ${\.{Q}}$ of the common carotid artery was decreased (p<0.05) and PR through the head was increased, ${\.{Q}}$ of the brachial artery was increased (p<0.05) and PR through forelimbs was decreased. ${\.{Q}}$ of the forepaw was initially increased (p<0.05) and then slightly decreased, on the whole revealing an increasing trend. Plasma norepinephrine was slightly decreased and the epinephrine was slightly increased. f was increased and arterial pH was increased (p<0.05). In conclusion, the central blood pooling during HDT shows an increased HR via Bainbridge reflex and an increased ${\.{Q}}$ of the forepaw and brachial ${\.{Q}}$, due to decreased PR which may be originated from the depressor reflex of cardiopulmonary baroreceptors. It is suggested that the blood flow to the brain was adequately regulated throughout HDT $(-6^{\circ}C)$ in spite of central blood pooling. And it is apparent that the changes of plasma norepinephrine level are inversely proportional to those of ${\.{Q}}$ of the forepaw, and the changes of epinephrine level are paralleled with those of the brachial ${\.{Q}}$.

  • PDF

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

Experimental Study on Distally Based Free Flap Using Retrograde Arterial Flow (역행성 동맥 혈류를 이용한 원위 유리피판술의 실험적 연구)

  • Lee, Min-Goo;Minn, Kyung-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.15-19
    • /
    • 1998
  • Microsurgical free-tissue transfer has allowed surgeons to salvage injured limbs but choosing appropriate healthy recipient vessels has proved to be a difficult problem. Retrograde flow flaps are established in island flaps. Retrograde flow anastomosis could prevent the possible kinking and twisting of the arterial anastomosis. By not interrupting the proximal blood flow to the fracture or soft tissue defect site, the compromise of fracture or wound healing might be prevented. We wished to estabilish an animal model in rat for a retrograde arterial flow based free flap. Nembutal-anesthetized male rats; weighing 250 to 300 gm, were used. The femoral artery and common carotid artery were exposed and divided. The systemic and retrograde arterial pressure were quantified by utilizing a parallel tubing system connected with peripheral arterial line. In this study, the retrograde flow was not pulsatile and the retrograde arterial pressure was 64-65mmHg, with a mean arterial pressure of 106-109mmHg. An epigastiic skin flap, measuring $3{\times}3cm$, was raised with its vascular pedicle. The epigastric free flap was transfered in the same rat from femoral vessels to carotid vessels in end to end fashion. We anastomosed the donor arteries to the distal parts of the divided recipient arteries and the donor veins to the proximal parts of the recipient veins. Twelve experiments were performed and the transplantations succeeded in 75 percent of them. In the remaining 25 percent, the experiments failed due to thrombosis at the site of anastpmosis, or other causes. This animal model represents an excellent example of retrograde arterial flow free flap transfer that is reliable.

  • PDF

Experimental Study of Patholobi Caulis on the Transient Cerebral Ischemia in Rats (계혈등(鷄血藤) 추출물이 뇌허혈에 미치는 실험적 연구)

  • Lee, Sang-Lok;Choi, Chan-Hun;Baek, Jin-Ung;Youn, Dae-Hwan;Jeong, Sang-Hun;Han, Ung;Jeong, Hyun-Woo;Kim, Gye-Yeop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.1127-1134
    • /
    • 2007
  • The study was designed to investigate the mechanism of Patholoobi Caulis freeze dried powder (PCF) on the regional cerebral blood flow (rCBF) and mean arterial blood pressure (MABP) in normal rats and cytokines production ($IL-1{\beta}$, $TNF-{\alpha}$, IL-10, $TGF-{\beta}$) in cerebral ischemic rats. The results in normal rats were as follows ; Increase of PCF-induced rCBF was significantly inhibited by pretreatment with methylene blue (10 ${\mu}g/kg$, I.p.), an inhibitor of guanylate cyclase, and was inhibited by indomethacin (1 mg/kg, i.p.), an inhibitor of cyclooxygenase. Increase of PCF-induced MABP was decreased by pretreatment with methylene blue, but was increased by indomethacin. These results suggested that the mechanism of action PCF was mediated by cyclic 3',5'-guanosine monophosphate. The results in cerebral ischemic rats were as follows ; In cytokine production in serum from femoral arterial blood 1 hr after middle cerebral arterial occlusion, PCF (10 mg/kg. i.p.) significantly decreased $IL-1{\beta}$ and $TNF-{\alpha}$ production, and increased IL-10 production compared with control group. In cytokine production in serum from femoral arterial blood 1 hr 1 hr after reperfusion, PCF (10 mg/kg, i.p.) significantly decreased $IL-1{\beta}$ production, and incresed IL-10 production compared with control group. These results suggested that PCF was significantly and stably increased regional cerebral blood flow by inhibiting $IL-1{\beta}$ production, and by accelerating IL-10 production.

Automated Drug Infusion System Based on Fuzzy PID Control during Acute Hypotension

  • Kashihara, Koji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.186-189
    • /
    • 2005
  • In a clinical setting, developing a reliable method for the automated drug infusion system would improve a drug therapy under the unexpected and acute changes of hemodynamics. The conventional proportional-integral-derivative (PID) controller might not be able to achieve maximum performance because of the unexpected change of the intra- and inter-patient variability. The fuzzy PID control and the conventional PID control were tested under the unexpected response of mean arterial blood pressure (MAP) to a vasopressor agent during acute hypotension. Compared with the conventional PID control, the fuzzy PID control performed the robust MAP regulation regardless of the unexpected MAP response (average absolute value of the error between target value and actual MAP: 0.98 vs. 2.93 mmHg in twice response of the expected MAP and 2.59 vs. 9.75 mmHg in three-times response of the expected MAP). The result was due to the adaptive change of the proportional gain in PID parameters.

  • PDF

Effects of Sin Bee Tang Water Extract on the Renal Function, Arterial Blood Pressure and Plasma Cortisol Concentration in the Rabbit (신비탕(神秘湯) 전탕액(煎湯液)이 가토(家兎)의 신장기능(腎臟機能), 혈압(血壓) 및 혈장(血漿) Cortisol농도(濃度)에 미치는 영향(影響))

  • Chung, Jae-Woo;Han, Sang-Whan
    • The Journal of Internal Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.125-136
    • /
    • 1989
  • This study was investigated to clarify the effect of Sin Bee Tang (神秘湯) on the renal function, arterial blood pressure and plasma cortisol. The results obtained were follows; 1. Urine volume and glomerular filtration rate were decreased significantly after Sin Bee Tang water extract, 0.1ml/kg, administration. 2. Glomerular filtration rate, renal plasma flow and urinary excretion of electrolytes were increased significantly after Sin Bee Tang water extract, 0.25ml/kg, administration. 3. Plasma cortisol concentration increased significantly after Sin Bee Tang water extract, 0.25ml/kg, administration. These results suggest that the therapeutic action of Sin Bee Tang for 'Su Chun (水喘)' has a relation with the increase of plasma cortisol and renal hemodynamic effect.

  • PDF

Measurement of Noninvasive Mean Arterial Pressure using Tonometry Pressure Sensor (압력센서 가압방식의 평균혈압 측정에 관한 연구)

  • Park, Mi-Kyoung;Huh, Young;Kang, Hee-Jung;Kim, Kyoung-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.859-860
    • /
    • 2006
  • We developed a cuffless and noninvasive measurement technique of blood pressure using tonometric pressure sensor. With observation that the maximum value of pulse pressure is not obtained at mean arterial pressure(MAP), we have figured out MAP based on the physiological characteristic including the elasticity of wrist tisse. Detecting only one part of the body and using only one device are quite advantageous over other BP measurement techniques. Our technique makes new way for the cuffless BP measurement.

  • PDF