• Title/Summary/Keyword: arterial blood pressure

Search Result 606, Processing Time 0.027 seconds

Comparison of the anesthetic effects of 2,2,2-tribromoethanol on ICR mice derived from three different sources

  • Lee, Mi Ree;Suh, Hye Rin;Kim, Myeong Whan;Cho, Joon Young;Song, Hyun Keun;Jung, Young Suk;Hwang, Dae Youn;Kim, Kil Soo
    • Laboraroty Animal Research
    • /
    • 제34권4호
    • /
    • pp.270-278
    • /
    • 2018
  • This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, $Avertin^{(R)}$) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak $CO_2$ ($ETCO_2$), mean arterial blood pressure, heart rate, oxygen saturation ($SpO_2$), body temperature, pH, $PCO_2$, and $PO_2$ of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, $SPO_2$, arterial blood $PCO_2$, and $PO_2$, which decreased after TBE anesthesia, or in heart rate and $ETCO_2$, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.

Multibody Dynamics in Arterial System

  • Shin Sang-Hoon;Park Young-Bae;Rhim Hye-Whon;Yoo Wan-Suk;Park Young-Jae;Park Dae-Hun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권spc1호
    • /
    • pp.343-349
    • /
    • 2005
  • There are many things in common between hemodynamics in arterial systems and multibody dynamics in mechanical systems. Hemodynamics is concerned with the forces generated by the heart and the resulting motion of blood through the multi-branched vascular system. The conventional hemodynamics model has been intended to show the general behavior of the body arterial system with the frequency domain based linear model. The need for detailed models to analyze the local part like coronary arterial tree and cerebral arterial tree has been required recently. Non-linear analysis techniques are well-developed in multibody dynamics. In this paper, the studies of hemodynamics are summarized from the view of multibody dynamics. Computational algorithms of arterial tree analysis is derived, and proved by experiments on animals. The flow and pressure of each branch are calculated from the measured flow data at the ascending aorta. The simulated results of the carotid artery and the iliac artery show in good accordance with the measured results.

Additive Role of the Vestibular End Organ and Baroreceptors on the Regulation of Blood Pressure in Rats

  • Lan, Yan;Yang, Yan-Zhao;Jiang, Xian;Li, Li-Wei;Jin, Guang-Shi;Kim, Min Sun;Park, Byung Rim;Jin, Yuan-Zhe
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제17권4호
    • /
    • pp.367-373
    • /
    • 2013
  • Contribution of the vestibular end organ to regulation of arterial pressure was quantitatively compared with the role of baroreceptors in terms of baroreflex sensitivity and c-Fos protein expression in the rostral ventrolateral medulla (RVLM). Baroreflex sensitivity and c-Fos protein expression in the RVLM were measured in conscious rats that had undergone bilateral labyrinthectomy (BL) and/or baroreceptor unloading. BL attenuated baroreflex sensitivity during intravenous infusion of sodium nitroprusside (SNP), but did not significantly affect the sensitivity following infusion of phenylephrine (PE). Baroreflex sensitivity became positive following sinoaortic denervation (SAD) during infusion of PE and attenuated sensitivity during infusion of SNP. Baroreflex sensitivity also became positive following double ablation (BL+SAD) during infusion of PE, and attenuated sensitivity during infusion of SNP. c-Fos protein expression increased significantly in the RVLM in the sham group after SNP administration. However, the BL, SAD, and SAD+BL groups showed significant decreases in c-Fos protein expression compared with that in the sham group. The SAD group showed more reduced c-Fos protein expression than that in the BL group, and the SAD+BL group showed less expression than that in the SAD group. These results suggest that the vestibular system cooperates with baroreceptors to maintain arterial pressure during hypotension but that baroreceptors regulate arterial pressure during both hypotension and hypertension. Additionally, afferent signals for maintaining blood pressure from the vestibular end organs and the baroreceptors may be integrated in the RVLM.

An Automatic Control System of the Blood Pressure of Patients Under Surgical Operation

  • Furutani, Eiko;Araki, Mituhiko;Kan, Shugen;Aung, Tun;Onodera, Hisashi;Imamura, Masayuki;Shirakami, Gotaro;Maetani, Shunzo
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권1호
    • /
    • pp.39-54
    • /
    • 2004
  • We developed an automatic blood pressure control system to maintain the blood pressure of patients at a substantially low level during a surgical operation. The developed system discharges two functions, continuous feedback control of the mean arterial pressure (MAP) by a state-predictive servo controller and risk control based on the inference by fuzzy-like logics and rules using measured data. Twenty-eight clinical applications were made beginning in November 1995, and the effects of the automatic blood pressure control on the operation time and on bleeding were assessed affirmatively by means of Wilcoxon testing. This paper essentially reports the engineering details of the control system.

Peptides derived from high voltage-gated calcium channel β subunit reduce blood pressure in rats

  • Hyung Kyu Kim;Jiyeon Jun;Tae Wan Kim;Dong-ho Youn
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제27권5호
    • /
    • pp.481-491
    • /
    • 2023
  • The β subunits of high voltage-gated calcium channels (HGCCs) are essential for optimal channel functions such as channel gating, activation-inactivation kinetics, and trafficking to the membrane. In this study, we report for the first time the potent blood pressure-reducing effects of peptide fragments derived from the β subunits in anesthetized and non-anesthetized rats. Intravenous administration of 16-mer peptide fragments derived from the interacting regions of the β1 [cacb1(344-359)], β2 [cacb2(392-407)], β3 [cacb3(292-307)], and β4 [cacb4(333-348)] subunits with the main α-subunit of HGCC decreased arterial blood pressure in a dose-dependent manner for 5-8 min in anesthetized rats. In contrast, the peptides had no effect on the peak amplitudes of voltage-activated Ca2+ current upon their intracellular application into the acutely isolated trigeminal ganglion neurons. Further, a single mutated peptide of cacb1(344-359)-cacb1(344-359)K357R-showed consistent and potent effects and was crippled by a two-amino acid-truncation at the N-terminal or C-terminal end. By conjugating palmitic acid with the second amino acid (lysine) of cacb1(344-359)K357R (named K2-palm), we extended the blood pressure reduction to several hours without losing potency. This prolonged effect on the arterial blood pressure was also observed in non-anesthetized rats. On the other hand, the intrathecal administration of acetylated and amidated cacb1(344-359)K357R peptide did not change acute nociceptive responses induced by the intradermal formalin injection in the plantar surface of rat hindpaw. Overall, these findings will be useful for developing antihypertensives.

Pharmacological Evidence that Calcitonin Gene-Related Peptide is Implicated in Cerebral Autoregulation

  • Hong, Ki-Whan;Pyo, Kwang-Min;Yu, Sung-Sook;Rhim, Byung-Yong
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1994년도 춘계학술대회 and 제3회 신약개발 연구발표회
    • /
    • pp.287-287
    • /
    • 1994
  • In the present study, it was aimed to asses the possibility that calcitonin gene-related peptide (CGRP) released in response to transient hypotension may contribute to the reflex autoregulation of cerebral blood flow as a putative modulator. Changes in pial arterial diameter (mean, 33.0 ${\pm}$ 1.1 $\mu\textrm{m}$) with changes in systemic arterial blood pressure (mean, 101.9 ${\pm}$ 2.7 mmHg) were observed directly through a closed cranial window in anesthetized normotensive rats. Image of the pial vessels was captured with a stereoscope connected to a CCD video camera and the diameter was measured with a microscaler. In the capsaicin-treated rats (one day prior to experiment, 50 nmol capsaicin injected intracisternally), both vasodilater and vasoconstrictor responses evoked by a transient hypotension and the reverse of blood pressure were markedly attenuated or almost abolished. When changes in pial arterial diameter were plotted as a function of changes in blood pressure, the slopes of both regression lines (for vasodilators and vasoconstrictors ) were markedly reduced. Similar reductions were evidenced under treatment wi th the CGRP antibody serum (1:1,000) and following CGRP receptor desensitization. However, the autoregulatory mechanics were neither affected by treatment wi th spantide (1 ${\mu}$M), substance P antagonist, nor by substance P receptor desensitization. Suffusion wi th mock cerebrospinal fluid containing CGRP and cromakalim caused a vasodilatation in a concentration-dependent manner, respectively and their effects were antagonized by glibenclamide. Substance P produced a vasodilatation, which was, however, little affected by glibenclamide. These observations indicate that the CGRP released from the perivascular sensory fibers in response to a hypotension is implicated in the modulation of the autoregulation of cerebral blood flow.

  • PDF

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

이중 박동성 인공심폐기의 동물 실험 (Application of the Pulsatile Cardiopulmonary Bypass in Animal Model)

  • 신화균;원용순;이재욱;허균;염욱;김승철;민병구
    • Journal of Chest Surgery
    • /
    • 제37권1호
    • /
    • pp.1-10
    • /
    • 2004
  • 배경: 기존에 사용되고 있는 인공심폐기는 비박동성 펌프로 회로 내부에 형성되는 압력이 낮고 혈구 손상이 적어서 표준 인공 심폐기로 선호되고 있다. 그러나 많은 실험적 연구들을 보면 박동성 관류가 혈역학, 대사, 장기의 기능, 미세 순환에 대하여 비박동성 관류보다 유익함을 알 수 있다. 그러나 박동성 인공심폐기는 높은 회로 내부 압력과 혈구손상이 해결되어야 할 문제점으로 개발이 어려웠다. 이 연구의 목적은 국내에서 제작된 이중 박동성 인공심폐기의 안전성 및 유효성을 알아보는 것이다. 대상 및 방법: 6마리의 송아지를 대상으로 이중 박동성 인공 심폐기 실험을 하였으며, 완전체외순환을 시켰다. 체외순환은 상,하 대정맥과 대동맥 사이를 우회하였으며, 막형 산화기를 사용하여 혈액을 산화시켰다. 산화기는 좌우측 펌프 중간에 위치시켰다. 순환 시간은 4시간이었다. 동맥혈가스분석, 혈액검사, 혈장 유리 혈색소를 측정하였으며, 맥압과 회로 내부압력을 관찰하였다. 측정은 인공 심폐기 구동 전과 순환 1, 2, 3, 4시간째에 측정하였다. 결과: 동맥혈 가스분석상 pH, 이산화 탄소분압은 모두 정상 범위였으며, 동맥혈 산소 분압은 100 mmHg 이상의 충분한 산화를 보였다. 혈장 유리혈색소는 완전 체외순환하여 4시간이 경과하면서 15.87 $\pm$5.63 mg/㎗로 점차 증가소견을 보였으나 20 mg/㎗ 이내였다. 혈액검사소견상 뚜렷한 이상소견은 없었다. 순환전 수축기 혈압은 97.5$\pm$5.7 mmHg이었으며 시간 경과하여도 100 mmHg 이상의 혈압을 유지하였다. 확장기 혈압은 72.2$\pm$7.7 mmHg이었으며 시간 경과하여도 잘 유지되었다. 평균 혈압은 순환 전 83$\pm$9.2 mmHg이었으며, 시간 경과 시 증가된 소견을 보였다. 펌프의 유량은 3.3 L/min이상을 유지할 수 있었다. 완전체외순환 동안의 혈압의 변화를 보면 순환 전 심장과 유사한 동맥혈압을 보였다. 결론: 이중 박동 구조를 이용한 박동성 인공심폐기는 효과적인 박동성 혈류를 제공하면서 혈구 세포손상도 적었으며, 혈액학적 및 혈역학적인 면에서도 우수한 결과를 보였다. 따라서 모든 심장수술의 인공심폐기로 사용되어질 경우 말초장기에 생리적이고 안정적인 혈류를 공급할 수 있을 것으로 기대된다.

동맥혈 및 뇨 $P_CO_2}, P{O_2}$ 의 산-염기 균형 및 뇨량과의 관계 (Relationships between arterial and urinary $P_CO_2}, P{O_2}$ and acid-base balances)

  • 김용진;이영균
    • Journal of Chest Surgery
    • /
    • 제16권2호
    • /
    • pp.213-220
    • /
    • 1983
  • Pulmonary function is the determinant of blood gas tension. However, Acid-Base disturbances can also alter partial pressures of oxygen and carbon dioxide in arterial blood. During respiratory acidosis $PO_2$ will be lowered and reverse changes will be produced during respiratory alkalosis. On the other hand, in metabolic acidosis $PO_2$ will be elevated and $PCO_2$ will be lowered by the respiratory compensation, and reverse response will be induced in metabolic alkalosis. Urinary gas tension has many influencing factors than arterial blood and difficult to estimate the tendency of its alterations. Urinary $PO_2$ and $PCO_2$ are not always identical level as venous blood. It is to be altered by blood gas tension, flow rate of urine, metabolic rate of kidney, and Acid-Base status of blood. Particularly countercurrent exchange of oxygen and carbon dioxide in the renal medulla will make larger alteration of gas tension than venous blood. After induction of Acid-Base disturbances [disturbances] arterial and urinary $PCO_2$, $PO_2$, urinary volume, and osmolarity were determined in dogs, and the relationships between arterial and urinary $PCO_2$ , $PO_2$ Acid-Base disturbances, urinary volume, and osmolarity were investigated. 1. During the acute Metabolic and Respiratory disturbances urinary pH did not respond on respiratory origin. However, there were immediate urinary response in pH on metabolic origin. 2. Urinary $PO_2$, $PCO_2$, did not always follow arterial or venous gas tension and Acid-Base disturbance. Urinary $PCO_2$, correlate well with the urinary volume. The larger the urinary volume, $PCO_2$ lowered to the venous level. The smaller the urinary volume, urinary $PCO_2$ tends to be higher. However urinary $PO_2$ did not have any particular correlation with urinary volume. 3. Correlation between urinary $PCO_2$ and $PO_2$ were inversely proportional to arterial blood. Differences of $PCO_2$ between arterial blood and urine also did not have any particular correlation with urinary volume. This may suggest that changes on blood gas tensions can influence on urinary $PCO_2$. 4. There were eminent clear inverse correlation between urinary $PCO_2$ and osmolar concentrations of urine. Above results strongly suggest that partial pressure of gas in urine primarily depend upon counter-current exchanges in renal medullary tissues.

  • PDF

좌심실보조장치의 출구 캐뉼라의 삽관 위치에 따른 혈액관류에 대한 시뮬레이션 연구 (Simulation Study of Blood Perfusion according to Outflow Cannulation Site of Left Ventricular Assist Device)

  • 지인혁;김형균;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.135-142
    • /
    • 2015
  • Outflow cannulation site of left ventricular assist device(LVAD) chosen by considering anatomical structure of thoracic cavity and vascular system. Though outflow cannulation site influences blood perfusion at each branch, there is no standard rule or quantitative data. In this study, we computed the amount of blood perfusion at each arterial branch numerically according to outflow cannulation sites(ascending aorta, aortic arch, descending aorta). We generated computational meshes to the three-dimensionally reconstructed arterial system. Clinically measured arterial pressure were used for inlet boundary condition, porous media were applied to mimic blood flow resistance. Blood perfusion through left common carotid artery was 2.5 times higher than other cases, and that through right common carotid artery was 1.1 times higher than other branches. Although this is simulation study, will be useful reference data for the clinical study of LVAD which considers blood perfusion efficiency.