• Title/Summary/Keyword: arrayed tip

Search Result 6, Processing Time 0.017 seconds

Arrayed Tip based Pattern Lithography with Built-in Capacitive Proximal Leveling Sensor (내장형 정전용량 근접 센서를 이용한 다중 팁 기반 패턴 인쇄)

  • Han, Yoonsoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.5
    • /
    • pp.239-245
    • /
    • 2019
  • To increase the throughput of tip-based nanolithography (TBN), one approach is to use a large array of such tips working in parallel. It is important to maintain co-planarity between the tip array and the writing surface. A slight misalignment can cause large discrepancies of contact force and feature sizes. We report a capacitive proximity sensor built-in with the TBN array for leveling an arrayed polymer pen array. The device allows alignment between an array of writing tips and the writing substrate without contact and contamination. The angular sensitivity of the sensor is $0.05^{\circ}$ for an array with maximum tip-to-tip separation of 100 mm.

2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors (GMR센서 배열을 이용한 자석팁의 2D 위치 추정)

  • Lee, S.C.;Kim, J.K.;Ahn, J.H.;Kim, H.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.395-401
    • /
    • 2019
  • This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X-ray is investigated. The sensor's voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33-55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.

The Magnetic Sensor with Lateral Field Emitter Arrays (평면구조의 전계방출형 자기 센서)

  • 남명우;김시헌;남태철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.124-128
    • /
    • 1995
  • We have fabricated the vacuum magnetic device with a lateral field emitter arrays constructed on n-Si wafer, and investigated its magnetic characteristics. The device is consited to tip-arrayed emitter. gate and split-anode, The fabricated vacuum magnetic device has showed a good linearity of magnetic field and a high sensitivity compared with the conventional semiconductor magnetic device.

  • PDF

On-site water level measurement method based on wavelength division multiplexing for harsh environments in nuclear power plants

  • Lee, Hoon-Keun;Choo, Jaeyul;Shin, Gangsig;Kim, Sung-Man
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2847-2851
    • /
    • 2020
  • A simple water level measurement method based on wavelength division multiplexing (WDM) is proposed and demonstrated. The measurement principle is based on the change of Fresnel reflection occurring at the end facet of the optical fiber tip (OFT). To increase the spatial resolution of water level sensing, a broadband light source (BLS) and an arrayed waveguide grating (AWG) are employed. The OFTs are multiplexed with the dedicated wavelength channels of AWG. By measuring all of the reflection powers reflected at the OFTs with a proposed on-site reflectometer, the water level can be monitored continuously for a fast emergency response. Moreover, it can be implemented easily with the commercially available optical components and devices with the simple configuration.

Evaluation of Convective Heat Transfer Performance of Twist-Vane Spacer Grid in Rod Bundle Flow (봉다발 유동 내 비틀림 혼합날개 지지격자의 대류열전달 성능 평가)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • The performance of convective heat transfer in rod bundle flow was experimentally evaluated using a twist-vane spacer grid. A $4{\times}4$ square-arrayed rod bundle was prepared as the test section, with a pitch-to-diameter ratio(P/D) of ~1.35. To check the convective heat transfer performance, the circumferential and longitudinal variations in rod-wall temperatures were measured downstream of the twist-vane spacer grid. In the circumferential measurements, the rod-wall temperature toward the twist-vane tip showed the lowest value, which might be due to the deflected water flow caused by the twist-vane. On the other hand, the wall temperature of the longitudinal measurements near the twist-vane spacer grid decreased dramatically, which implies that the convective heat transfer performance was enhanced. A heat transfer enhancement of ~35 % was achieved near downstream of the twist-vane spacer grid, as compared with the upstream value. Based on the present experimental data, a correlation for predicting the heat transfer performance of a twist-vane spacer grid was proposed.

Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly (이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • The forced convection heat transfer performance of a twist-vane spacer grid for a dual-cooled annular fuel assembly was examined experimentally. The twist-vane spacer grid was uniquely designed to enhance mixing inside subchannels and mixing between adjacent subchannels. For testing, a $4{\times}4$ square-arrayed rod bundle with narrow gaps between rods was prepared as the dual-cooled annular fuel assembly to be simulated. The pitch-to-rod diameter ratio of simulated dual-cooled annular fuel assembly was 1.08. The experiments were performed under the following conditions: axial bulk velocity, 1.5 m/s and heat flux, $26kW/m^2$. With regard to the circumferential temperature distribution, the lowest rod-wall temperatures upstream and downstream were measured at the subchannel center and the position toward the tip of twist-vane, respectively. With regard to the axial temperature distribution, behind the twist-vane spacer grid, the rod-wall temperature decreased drastically, and the Nusselt number was enhanced by up to 56 %. The present measured data indicate that the twist-vane spacer grid can effectively improve the forced convection heat transfer in the dual-cooled annular fuel assembly with narrow gaps.