• 제목/요약/키워드: array sensors

Search Result 478, Processing Time 0.031 seconds

A study on the low-frequency of acoustic sensor using single mode FBG (Fiber Bragg Grating). (단일모드 광섬유 브래그 격자를 이용한 저주파수 대역의 음향 센서에 관한 연구)

  • Kim, Kyung-Bok;Kwack, Kae-Dal
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.396-403
    • /
    • 2000
  • The low- frequency acoustic sensor using the recently developed FBG has an excellent merits which the existing fiber-optic sensor has and also it has an excellent signal sensing effect in the environment of low-frequency($30Hz{\sim}300Hz$). Furthermore, we can expect the utilization of low-frequency signal defection instead of existing microphones in the environment of electric noise and also it can be developed as the high-sensibility multiplexing through the sensor array system.

  • PDF

Development of fabric-based optical fiber tactile sensor using optical fiber bending loss (광섬유 굽힘 손실을 이용한 직물 기반의 광섬유 촉각센서 개발)

  • Kim, Ju-Young;Baek, Sang-Ho;Lee, Jung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.210-216
    • /
    • 2009
  • In this paper the tactile sensor system based on the bending loss of optical fiber sensor is presented. The sensor array was designed with fabric structure. The optical measuring system was composed of LED for light source and CCD camera for the signal light detector. Performance of this tactile sensor system was evaluated in various environments and compared with Harmon's design criteria. The result shows that load range is 3 g$\sim$100 g, resolution is 1.5 g, hysteresis error is 1.5%. The response linearity is good and flexibility of sensor array is excellent.

Sweeping Linearization of Wavelength Swept Laser using PID Control (PID 제어를 이용한 파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a PID control method for sweeping automatic linearization of a wavelength swept laser is proposed. First, the closedloop transfer function embodying the PID control is derived. Through the simulation of the function, Kp = 0.022, Ki = 0.008, Kd = 0.002 were obtained as the best PID coefficients for fast linear sweeping. The performance test using the PID coefficients showed that linear sweeping was held up well with a 98.7% decrement in nonlinearity after the 10th feedback, and 45 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The equipment consists of a fiber Bragg grating array, an optical-electronic conversion circuit, and a LabVIEW FPGA program. Every 5s, automatic feedback and PID control generate a new compensated waveform and produce a better linear sweeping than before. Compared with nonlinear sweeping, linear sweeping can reduce the cumbersome and time-consuming recalibration processes and produce more accurate measurement results.

3D PROCESSING OF HIGH-RESOLUTION SATELLITE IMAGES

  • Gruen, Armin;Li, Zhang
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.24-27
    • /
    • 2003
  • High-resolution satellite images at sub-5m footprint are becoming increasingly available to the earth observation community and their respective clients. The related cameras are all using linear array CCD technology for image sensing. The possibility and need for accurate 3D object reconstruction requires a sophisticated camera model, being able to deal with such sensor geometry. We have recently developed a full suite of new methods and software for the precision processing of this kind of data. The software can accommodate images from IKONOS, QuickBird, ALOS PRISM, SPOT5 HRS and sensors of similar type to be expected in the future. We will report about the status of the software, the functionality and some new algorithmic approaches in support of the processing concept. The functionality will be verified by results from various pilot projects. We put particular emphasis on the automatic generation of DSMs, which can be done at sub-pixel accuracy and on the semi-automated generation of city models.

  • PDF

Intelligent Olfactory Sensor (지능형 후각센서)

  • Lee, D.S.;Ahn, C.G.;Kim, B.K.;Pyo, H.B.;Kim, J.T.;Huh, C.;Kim, S.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.4
    • /
    • pp.76-88
    • /
    • 2019
  • With advances in olfactory sensor technologies, the number of reports on various intelligent applications using multiple sensors (sensor arrays) are continuously increasing for fields such as medicine, environment, security, etc. For intelligent and point-of-care applications, it is not only important for the sensor technology to perform chemical or physical measurements rapidly and accurately, but it is also important for artificial intelligence technology to recognize and quantify specific chemicals or diagnose diseases such as lung cancer and diabetes. In particular, great advances in pattern recognition technologies, including deep learning algorithms, as well as sensor array technologies, are expected to enhance the potential of various types of olfactory intelligence applications, including early cancer diagnosis, drug seeking, military operations, and air pollution monitoring.

Thermo-mechanical Design for On-orbit Verification of MEMS based Solid Propellant Thruster Array through STEP Cube Lab Mission

  • Oh, Hyun-Ung;Ha, Heon-Woo;Kim, Taegyu;Lee, Jong-Kwang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.526-534
    • /
    • 2016
  • A MEMS solid propellant thruster array shall be operated within an allowable range of operating temperatures to avoid ignition failure by incomplete combustion due to a time delay in ignition. The structural safety of the MEMS thruster array under severe on-orbit thermal conditions can also be guaranteed by a suitable thermal control. In this study, we propose a thermal control strategy to perform on-orbit verification of a MEMS thruster module, which is expected to be the primary payload of the STEP Cube Lab mission. The strategy involves, the use of micro-igniters as heaters and temperature sensors for active thermal control because an additional heater cannot be implemented in the current design. In addition, we made efforts to reduce the launch loads transmitted to the MEMS thruster module at the system level structural design. The effectiveness of the proposed thermo-mechanical design strategy has been demonstrated by numerical analysis.

ROLL AND PITCH ESTIMATION VIA AN ACCELEROMETER ARRAY AND SENSOR NETWORKS

  • Baek, W.;Song, B.;Kim, Y.;Hong, S.K.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.753-760
    • /
    • 2007
  • In this paper, a roll and pitch estimation algorithm using a set of accelerometers and wireless sensor networks(S/N) is presented for use in a passenger vehicle. While an inertial measurement unit(IMU) is generally used for roll/pitch estimation, performance may be degraded in the presence of longitudinal acceleration and yaw motion. To compensate for this performance degradation, a new roll and pitch estimation algorithm is proposed that uses an accelerometer array, global positioning system(GPS) and in-vehicle networks to get information from yaw rate and roll rate sensors. Angular acceleration and roll and pitch approximation are first calculated based on vehicle kinematics. A discrete Kalman filter is then applied to estimate both roll and pitch more precisely by reducing noise from the running engine and from road disturbance. Finally, the feasibility of the proposed algorithm is shown by comparing its performance experimentally with that of an IMU in the framework of an indoor test platform as well as a test vehicle.

Performance Analysis of Data Association Applied Frequency Weighting in 3-Passive Linear Array Sonars (주파수 가중치를 적용한 3조의 수동 선배열 소나 센서의 정보 연관 성능 분석)

  • 구본화;윤제한;홍우영;고한석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.109-116
    • /
    • 2004
  • This paper deals with data association using 3 sets of passive linear array sonars (PUS) geometrically positioned in a Y-shaped configuration, but fixed in an underwater environment. The data association problem is directly transformed into a 3-D assignment problem, which is known to be NP-hard. For generic passive sensors, it can be sotted using conventional algorithms, while it in PLAS becomes a formidable task due to the presence of bearing ambiguity. In particular, we proposed data association method robust to bearing measurements errors by incorporating frequency information and analyze a region of ghost problem by geometrical relation PUS and target. We analyzed the effectiveness of the proposed method by representative simulation in multi-target.

Bolometer-Type Uncooled Infrared Image Sensor Using Pixel Current Calibration Technique (화소 전류 보상 기법을 이용한 볼로미터 형의 비냉각형 적외선 이미지 센서)

  • Kim, Sang-Hwan;Choi, Byoung-Soo;Lee, Jimin;Oh, Chang-woo;Shin, Jang-Kyoo;Park, Jae-Hyoun;Lee, Kyoung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.349-353
    • /
    • 2016
  • Recently, research on bolometer-type uncooled infrared image sensor which is made for industrial applications has been increasing. In general, it is difficult to calibrate fixed pattern noise (FPN) of bolometer array. In this paper, average-current calibration algorithm is presented for reducing bolometer resistance offset. A resistor which is produced by standard CMOS process, on the average, has a deviation. We compensate for deviation of each resistor using average-current calibration algorithm. The proposed algorithm has been implemented by a chip which is consisted of a bolometer pixel array, average current generators, current-to-voltage converters (IVCs), a digital-to-analog converter (DAC), and analog-to-digital converters (ADCs). These bolometer-resistor array and readout circuit were designed and manufactured by $0.35{\mu}m$ standard CMOS process.

Disturbance Observer-Based Hybrid Control of Displacement and Force in a Medical Tele-Analyzer

  • Suebsomran Anan;Parnichkun Manukid
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.70-78
    • /
    • 2005
  • This paper presents hybrid control of displacement and force in a Medical Tele-Analyzer by disturbance observer-based controller which is robust to internal and external disturbances; model uncertainty, load, and friction for instances. The developed Medical Tele-Analyzer consists of 2 subsystems; doctor-side subsystem and patient-side subsystem. In the doctor side subsystem, an array of displacement sensor is equipped to detect movement of doctor's hand and fingers. The detected information is transmitted to the patient side to be used in medical analysis. On the other hand, the patient-side subsystem consists of an array of displacement actuators, which is used to follow displacement of doctor's hand and fingers. An array of force sensors is used to detect forces between patient and the equipment. Since displacement control in patient side is coupled with force control in doctor side and vice-versa, design of the controller has to take into account this coupling. Not only using in medical tele-analysis, the proposed system can also be used in any tele-displacement-force controls of industrial processes.