• Title/Summary/Keyword: array sensors

검색결과 478건 처리시간 0.035초

캔틸레버(Cantilever) 형태의 전극 어레이(array)를 이용한고속 분리 시스템 (High throughput sorting(HTS) system using a cantilever-type electrode array)

  • 이정훈;김영호;김영근;김병규
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.112-117
    • /
    • 2010
  • A high-throughput sorting (HTS) system has been designed to separate target particles using a negative dielectrophoretic (n-DEP) force. The system consists of a meso-sized channel and a cantilever-type electrode(CE) array designed to separate a large number of target particles by discerning subtle difference of weight and dielectric material property of the particles. Using the polystyrene beads with various sizes of 10, 25 and $50{\mu}m$, the developed system exhibits high-throughput sorting of about 200 beads/sec and more than 80 % of separation efficiency.

Silicon Nitride Cantilever Array Integrated with Si Heaters and Piezoelectric Sensors for Probe-based Data Storage

  • Nam Hyo-Jin;Kim Young-Sik;Lee Caroline Sunyong;Jin Won-Hyeog;Jang Seong-Soo;Cho Il-Joo;Bu Jong-Uk
    • 정보저장시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.73-77
    • /
    • 2005
  • In this paper, a new silicon nitride cantilever integrated with silicon heater and piezoelectric sensor has been firstly developed to improve the uniformity of the initial bending and the mechanical stability of the cantilever array for thermo-piezoelectric SPM(scanning probe microscopy) -based data storages. This nitride cantilever shows thickness uniformity less than $2\%$. Data bits of 40 nm in diameter were recorded on PMMA film. The sensitivity of the piezoelectric sensor was 0.615 fC/nm after poling the PZT layer. For high speed operation, 128${\times}$128 probe array was developed.

  • PDF

An Array-Based Sensor for Seafood Freshness Assessment

  • Gonzalez-Martin, Anuncia;Lewis, Brian;Raducanu, Marius;Kim, Jin-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3084-3092
    • /
    • 2010
  • This paper describes the development of an automated, hand-held sensor for the fast assessment of seafood freshness. The sensor developed here combined: an array-based chemical sensor, composed of incrementally different conducting polymer elements deposited on a small chip; a highly sensitive, custom-made electronics for the detection of very small signal changes; precise temperature control of the sensor chamber; and an on-board microcontroller for data collection, storage, automation, and analysis. The instrument was used to successfully test seafood samples with different degree of freshness and spoilage. A linear relationship between microbiological count and e-Nose signal for three different fish fillet was developed. Once the linear relationship is included into the hand-held unit software, the e-Nose signal can be used for assessment of seafood freshness without performing the microbiological count technique.

Fabrication of low-stress silicon nitride film for application to biochemical sensor array

  • 손영수
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.357-361
    • /
    • 2005
  • Low-stress silicon nitride (LSN) thin films with embedded metal line have been developed as free standing structures to keep microspheres in proper locations and localized heat source for application to a chip-based sensor array for the simultaneous and near-real-time detection of multiple analytes in solution. The LSN film has been utilized as a structural material as well as a hard mask layer for wet anisotropic etching of silicon. The LSN was deposited by LPCVD (Low Pressure Chemical Vapor Deposition) process by varing the ratio of source gas flows. The residual stress of the LSN film was measured by laser curvature method. The residual stress of the LSN film is 6 times lower than that of the stoichiometric silicon nitride film. The test results showed that not only the LSN film but also the stack of LSN layers with embedded metal line could stand without notable deflection.

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

병렬도체에서 선재의 배열형상에 따른 비접촉식 전류분류 측정 (Current sharing measurement using non-contact method for parallel HTS tapes conductor according to tape array geometry)

  • 변상범;박명진;최석진;박상호;이승욱;김우석;이지광;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.32-36
    • /
    • 2008
  • An HTS conductor with parallel HTS tapes is essential for a large power HTS device to flow a large current. One of the most important factor for this conductor is a current distribution. Non-uniform current distribution in parallel tapes makes the critical current of the conductor low and the AC losses high. In this paper we proposed a non-contact method which measured each current in parallel tapes by using an array of Hall sensors. A matrix can be derived from this array for calibration. The current distributions of 4 and 6 parallel tapes were measured.

Fiber-Optic Sensors

  • 김병운
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1988년도 광학 및 양자전자학 워크샵
    • /
    • pp.104-104
    • /
    • 1988
  • Single-mode 광섬유를 이용한 Sersor 및 그와 관련된 광섬유 device 의 작동원리 및 연구동향에 대하여 논의하였다. 논의된 광섬유 sersor 로는 intensity type sersor, fiber gyroscope, sensor array 등이 포함되어 있고, 관련 부품으로는 directional coupler, acousto-optic, fiber-optic amplifier 등이 설명되었다.

  • PDF

MoM 기법에 의한 다이폴 배열 안테나의 신호 방향 추정 방법 연구 (A Study on DOA Estimation Using Dipole Array Antenna Based on MoM)

  • 문상곤;이강인;양훈기;배경빈;정용식
    • 한국전자파학회논문지
    • /
    • 제22권7호
    • /
    • pp.661-668
    • /
    • 2011
  • 전파 신호 방향의 추정은 레이더 및 무선 통신에서 주요한 분야이다. 일반적으로 방향 탐지기법들은 이상적인 배열 센서의 입력 신호에 신호 처리 기법을 적용하여 연구를 진행해 왔다. 하지만 전파를 이용한 방향 탐지에서 사용되는 배열 센서인 안테나는 배열 구조에서 안테나 소자 간에 상호 결합으로 인한 입력 신호의 왜곡 현상이 발생하는 문제점이 있다. 그러므로 이러한 상호 결합에 의한 신호의 왜곡 현상을 보상하는 기법이 정밀한 방향 탐지를 위해서 필요하다. 본 논문에서는 다이폴 배열 안테나 구조에서 배열 소자 간의 상호 결합 현상을 MoM 기법을 이용하여 보상하고, 이를 통하여 신호원의 방위각 및 고각의 방향을 추정하는 연구를 진행하였다.

가스센서 어레이와 패턴인식을 활용한 아로마 오일의 특성 분류 (Characteristic Classification of Aroma Oil with Gas Sensors Array and Pattern Recognition)

  • 최일환;홍성주;김선태
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.118-125
    • /
    • 2018
  • An evaluation system for an electronic-nose concept using three types of metal oxide gas sensors that react similarly to the human olfactory cells was constructed for the quantitative and qualitative evaluation of aroma fragrances. Four types of aroma fragrances (lavender, orange, jasmine, and Roman chamomile), which are commonly used in aromatherapy, were evaluated. All the gas sensors reacted remarkably to the aroma fragrances and the good correlation of r=0.58-0.88 with the aromatic odor intensities by olfaction was confirmed. From the results of the analysis of an electronic-nose concept for classifying the characteristics of aroma oil fragrances, aroma oils could be classified using the fragrance characteristics and oil extraction methods with the cumulative variability contribution rate of 95.65% (F1: 69.65%, F2: 26.03%) by principal component analysis. In the pattern recognition based on the artificial neural network, the four aroma fragrances were 100% recognized through the training data of 56 cases (70%) out of 80 cases, and the pattern recognition rate was 57.1%-71.4% through the validation and testing data of 24 cases (30%). The pattern recognition success rate through all confusion matrices was 82.1%, indicating that the classification of aroma oil fragrances using the three types of gas sensors was successful.