• 제목/요약/키워드: arm function

검색결과 473건 처리시간 0.02초

상지 이용 유무와 훈련 기간이 무용 회전 동작의 기능에 미치는 영향 (The Effect of Upper Extremity Usage and Length of Training to the Function of Dance Turn)

  • 박양선;임영태
    • 한국운동역학회지
    • /
    • 제17권1호
    • /
    • pp.175-184
    • /
    • 2007
  • The first purpose of this study was to compare kinematic variables during spinning motion with or without upper extremity and identify the most effective spinning method. The second purpose of this study was to compare functional difference between novice and elite dancers with the term of training. Ten experienced female dancers and ten novices were recruited as subjects for this study. Elite group was asked to perform turn motion with three types of upper extremity. Novice group has taken training of spotting technique for five weeks. Four Falcon HiRES cameras were used to analyze kinematic variables including head angular velocity and CG displacement during spinning. These data were sampled before training, after 3-week, and 5-week of training. Eight different events in two consecutive turns were defined for statistical comparison. One-way ANOVA was performed to compare among the kinematics of turning motion with three types of upper extremity. Independent t-test also used to compare kinematics between elite and novice at three different length of training. As results, spinning with both arm increased angular velocity and stability compared to the turning motion with one arm or with arm strapped and found out that the turn with both arm was the most effective way of spin. Also, for novice dancers, three weeks of training were needed to complete spinning motion.

영상 정보를 이용한 ROBOKER 팔 위의 역진자 시스템의 지능 밸런싱 제어 구현 (Intelligent Balancing Control of Inverted Pendulum on a ROBOKER Arm Using Visual Information)

  • 김정섭;정슬
    • 한국지능시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.595-601
    • /
    • 2011
  • 본 논문에서는 영상 정보를 이용하여 로보커 팔위의 역진자의 밸런싱 제어를 한다. 로봇 팔위에 놓인 역진자의 각도는 카메라로 검출하고 검출된 각도 값은 제어기로 귀환되어 오차를 생성한다. 따라서 전체 제어루프는 폐회로 루프를 형성한다. 제어 성능을 높이기 위해 기존 선형제어기에 신경망 제어기를 더하였다. RBF 네트워크의 학습 알고리즘은 FPGA에 설계된 부동소수점 연산이 가능한 디지털 제어기에 의해 수행된다. 실험을 통하여 전체 시스템 성능을 검증하였다.

Optimizing Movement of A Multi-Joint Robot Arm with Existence of Obstacles Using Multi-Purpose Genetic Algorithm

  • Toyoda, Yoshiaki;Yano, Fumihiko
    • Industrial Engineering and Management Systems
    • /
    • 제3권1호
    • /
    • pp.78-84
    • /
    • 2004
  • To optimize movement of a multi-joint robot arm is known to be a difficult problem, because it is a kind of redundant system. Although the end-effector is set its position by each angle of the joints, the angle of each joint cannot be uniquely determined by the position of the end-effector. There exist the infinite number of different sets of joint angles which represent the same position of the end-effector. This paper describes how to manage the angle of each joint to move its end-effector preferably on an X-Y plane with obstacles in the end-effector’s reachable area, and how to optimize the movement of a multi-joint robot arm, evading obstacles. The definition of “preferable” movement depends upon a purpose of robot operation. First, we divide viewpoints of preference into two, 1) the standpoint of the end-effector, and 2) the standpoint of joints. Then, we define multiple objective functions, and formulate it into a multi-objective programming problem. Finally, we solve it using multi-purpose genetic algorithm, and obtain reasonable results. The method described here is possible to add appropriate objective function if necessary for the purpose.

Thoracic Hyperkyphosis affects Scapular Orientation and Trunk Motion During Unconstrained Arm Elevation

  • Park, Jae-man;Choi, Jong-duk;Han, Song-i
    • 한국전문물리치료학회지
    • /
    • 제26권4호
    • /
    • pp.53-62
    • /
    • 2019
  • Background: Shoulder function is achieved by the coordinated movements of the scapula, humerus, and thoracic spine, and shoulder disorders can be associated with altered scapular kinematics. The trunk plays an important role as the kinematic chain during arm elevation. Objects: The purpose of this study was to determine the effects of thoracic hyperkyphosis on scapular orientation and trunk motion. Methods: Thirty-one subjects (15 in the ideal thorax group and 16 in the thoracic hyperkyphosis group) performed right-arm abduction and adduction movements in an unconstrained plane. The scapular orientation and trunk motion were recorded using a motion analysis system. Results: Those subjects with thoracic hyperkyphosis displayed greater scapular posterior tilting at a $120^{\circ}$ shoulder elevation, greater scapular internal rotation throughout the arm raising phase, and greater trunk axial rotation at the upper ranges of the shoulder elevation, compared to those subjects with an ideal thorax (p<.05). Conclusion: Thoracic hyperkyphosis can cause scapular instability, greater trunk rotation and greater scapular posterior tilting, and may contribute to preventing the achievement of a full range of humeral abductions in an unconstrained plane.

INS/GNSS/NHC Integrated Navigation System Compensating for Lever Arm Effect between NHC Effective Point and IMU Mounting Location

  • Chae, Myeong Seok;Kwon, Jae Uk;Cho, Eui Yeon;Cho, Seong Yun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권3호
    • /
    • pp.199-208
    • /
    • 2022
  • Inertial Navigation System (INS)/Global Navigation Satellite System (GNSS) integrated navigation system can be used for land vehicle navigation. When the GNSS signal is blocked in a dense urban area or tunnel, however, the problem of increasing the error over time is unavoidable because navigation must be performed only with the INS. In this paper, Non-Holonomic Constraints (NHC) information is utilized to solve this problem. The NHC may correct some of the errors of the INS. However, it should be noted that NHC information is not applicable to all areas within the vehicle. In other words, the lever arm effect occurs according to the distance between the Inertial Measurement Unit (IMU) mounting position and the NHC effective point, which causes the NHC condition not to be satisfied at the IMU mounting position. In this paper, an INS/GNSS/NHC integrated navigation filter is designed, and this filter has a function to compensate for the lever arm effect. Therefore, NHC information can be safely used regardless of the vehicle's driving environment. The performance of the proposed technology is verified through Monte-Carlo simulation, and the performance is confirmed through experimental test.

해저 보행 로봇 CR200을 위한 매니퓰레이터 기능을 갖는 다리 개발 (Development of a Specialized Underwater Leg Convertible to a Manipulator for the Seabed Walking Robot CR200)

  • 강한구;심형원;전봉환;이판묵
    • 제어로봇시스템학회논문지
    • /
    • 제19권8호
    • /
    • pp.709-717
    • /
    • 2013
  • This paper presents the development of a specialized underwater leg with a manipulator function(convertible-to-arm leg) for the seabed walking robot named CRABSTER200(CR200). The objective functions of the convertible-to-arm leg are to walk on the seabed and to work in underwater for precise seabed exploration and underwater tasks under coastal area with strong tidal current. In order to develop the leg, important design elements including the degree of freedom, dimensions, mass, motion range, joint structure/torque/angular-speed, pressure-resistance, watertight capability and cable protection are considered. The key elements of the convertible-to-arm leg are realized through concept/specific/mechanical design and implementation process with a suitable joint actuator/gear/controller selection procedure. In order to verify the performance of the manufactured convertible-to-arm leg, a 25bar pressure-resistant and watertight test using a high-pressure chamber and a joints operating test with posture control of the CR200 are performed. This paper describes the whole design, realization and verification process for implementation of the underwater convertible-to-arm leg.

임베디드 ARM 기반의 5.8GHz DSRC 통신모뎀에 대한 SOC 구현 (Embedded ARM based SoC Implementation for 5.8GHz DSRC Communication Modem)

  • 곽재민;신대교;임기택;최종찬
    • 대한전자공학회논문지TC
    • /
    • 제43권11호
    • /
    • pp.185-191
    • /
    • 2006
  • DSRC(Dedicated Short Range Communication)은 도로변의 RSE(Road Side Equipment)와 고속으로 이동하는 차량의 단말인 OBE(On-Board Equipment)간의 통신을 위한 단거리 전용 무선 통신 표준이다. 본 논문에서는 국내의 TTA(Telecommunication Technology Association) 표준에 호환되는 DSRC 규격에 따라 5.8GHz DSRC 모뎀을 구현하고, 이를 제어하고 연산처리를 수행할 수 있도록 ARM9 CPU를 임베딩 시킨 SoC(System on a Chip)에 대한 구현과정 및 제작한 SoC를 장착시킨 OBE 단말의 테스트결과에 대해 제시하였다. 본 논문에서 구현한 SoC는 0.11 um 공정을 적용하였으며 480 핀 EPBGA 패키지로 설계되었다. 제작 SoC ($Jaguar^{TM}$)에는 5.8GHz용 DSRC PHY(Physical Layer) 모뎀과 MAC 블록을 설계하여 장착하였으며, ARM926EJ-S 코어를 CPU로 사용하였고, LCD 콘트롤러, 스마트카드 콘트롤러, 이더넷 MAC 코어, 메모리 콘트롤러 등을 주요 기능으로 포함시켰다.

DETERMINATION OF THE DISTANCE TO B 361 BY A MODIFIED VERSION OF THE WOLF DIAGRAM

  • Hong, S.S.;Sohn, D.S.
    • 천문학회지
    • /
    • 제22권1호
    • /
    • pp.63-79
    • /
    • 1989
  • Current estimates, based on the same star-count analysis, of the distance to the globule Bamard 361 range from 300 pc to 650 pc. All the problems associated with the estimates have been fully rectified in this study, and a modification has been made to the classical Wolf diagram to improve the accuracy in the distance determination. A reference field was carefully selected close to the globule but well outside the globule boundary, and star counts for this field were performed on the blue POSS plate in order to set up the reference magnitude sequence appropriate to the general area of B 361. From the reference sequence, the stellar density function has been derived specifically for the direction toward the globule. Correction was made for the general interstellar extinction, and the luminosity function with the Wielen's dip was adopted. The resulting density function clearly reveals the existence of the local Cygnus-Orion arm in the direction of B 361 at about 700 pc away from the Sun. Analysis of the star-count data for the program field locates the globule at distance $600{\pm}50$ pc ; thus, the globule is an object located in the Cygnus-Orion arm, residing somewhat toward its leading edge.

  • PDF

Approximated Generalized Torques by the Hydrodynamic Forces Acting on Legs of an Underwater Walking Robot

  • Jun, Bong-Huan;Shim, Hyung-Won;Lee, Pan-Mook
    • International Journal of Ocean System Engineering
    • /
    • 제1권4호
    • /
    • pp.222-229
    • /
    • 2011
  • In this paper, we present the concept and main mission of the Crabster, an underwater walking robot. The main focus is on the modeling of drag and lift forces on the legs of the robot, which comprise the main difference in dynamic characteristics between on-land and underwater robots. Drag and lift forces acting on the underwater link are described as a function of the relative velocity of the link with respect to the fluid using the strip theory. Using the translational velocity of the link as the rotational velocity of the joint, we describe the drag force as a function of joint variables. Generalized drag torque is successfully derived from the drag force as a function of generalized variables and its first derivative, even though the arm has a roll joint and twist angles between the joints. To verify the proposed model, we conducted drag torque simulations using a simple Selective Compliant Articulated Robot Arm.

Effects of Compression Materials on Hand Dexterity in the 40's Healthy Subjects: A Preliminary Study

  • Rhee, Hyeon-Sook;Yu, Jae-Ho;Kim, Sung-Joong
    • The Journal of Korean Physical Therapy
    • /
    • 제23권6호
    • /
    • pp.43-47
    • /
    • 2011
  • Purpose: The aim of this preliminary study was to use hand function tests to Hand dexterity levels provided by the type of compression garment and compression bandages in asymptomatic subjects and to collect baseline data for the comparison of hand functions in the patients with chronic arm lymphedema. Methods: The subjects of this study were 32 healthy volunteer female with a mean age of 45.8 years. Grip strength and hand functions were tested in three conditions-no compression, compression garment, and compression bandages-using the nine-hole peg test (NHPT), the box and block test (B&BT), Minnesota Manual Dexterity test (MMDT), and the hand-held Jamar dynamometer. Results: The grip strength was significantly low in the bandage condition (p<0.05). The performance in both compression groups (i.e., bandage and compression garment) decreased as the thickness of the compression material increased (p<0.05). Conclusion: The findings of this study suggest that grip strength and hand function scores are influenced by the characteristics of the compression applied. Future study is needed to determine the level of hand function between patients with chronic arm lymphedema and healthy individuals.