• Title/Summary/Keyword: arm CT

Search Result 67, Processing Time 0.024 seconds

Development of pre-procedure virtual simulation for challenging interventional procedures: an experimental study with clinical application

  • Seong, Hyunyoung;Yun, Daehun;Yoon, Kyung Seob;Kwak, Ji Soo;Koh, Jae Chul
    • The Korean Journal of Pain
    • /
    • v.35 no.4
    • /
    • pp.403-412
    • /
    • 2022
  • Background: Most pain management techniques for challenging procedures are still performed under the guidance of the C-arm fluoroscope although it is sometimes difficult for even experienced clinicians to understand the modified three-dimensional anatomy as a two-dimensional X-ray image. To overcome these difficulties, the development of a virtual simulator may be helpful. Therefore, in this study, the authors developed a virtual simulator and presented its clinical application cases. Methods: We developed a computer program to simulate the actual environment of the procedure. Computed tomography (CT) Digital Imaging and Communications in Medicine (DICOM) data were used for the simulations. Virtual needle placement was simulated at the most appropriate position for a successful block. Using a virtual C-arm, the authors searched for the position of the C-arm at which the needle was visualized as a point. The positional relationships between the anatomy of the patient and the needle were identified. Results: For the simulations, the CT DICOM data of patients who visited the outpatient clinic was used. When the patients revisited the clinic, images similar to the simulated images were obtained by manipulating the C-arm. Transforaminal epidural injection, which was difficult to perform due to severe spinal deformity, and the challenging procedures of the superior hypogastric plexus block and Gasserian ganglion block, were successfully performed with the help of the simulation. Conclusions: We created a pre-procedural virtual simulation and demonstrated its successful application in patients who are expected to undergo challenging procedures.

Clinical animal test for development of osseointegration implant;application for beagle tibia (골융합 임플란트 개발을 위한 동물임상실험;비글견 경골 적용)

  • Choi, Kyong-Joo;Kim, Shin-Ki;Mun, Mu-Seong;An, Jae-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1373-1377
    • /
    • 2003
  • Current prostheses for amputees are generally extrinsic wearing socket type that the coupling between body stump and appliance wraps the soft tissue and this structure causes several problems :applying direct weight to soft tissue such as skin and muscle, skin trouble of contacting area and pain. In this study, osseointegration implant is a method to directly connect prosthesis to the residual stump skeletal tissue of arm, finger and leg through surgical operation. Technology presented in this paper essentially solves the problems of pain and abnormal weight transfer system indicated above and recovers the functions of the amputated arm and leg. In this paper, implant shape was designed for the first step for the development of osseointegration implant and then we studied the possibility to apply this osseointegration implant to human body by performing implant insertion operation to beagle tibia for the clinical animal test and normal beagle's gait analysis was executed in order to quantitatively verify the beagle's skeletal functions after the implant insertion.

  • PDF

초고속 통신망을 이용한 척추 경나사못 삽입술 Simulator

  • 윤승식;성정환;최희원;김영호;강석호;염진섭
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1999.04a
    • /
    • pp.105-107
    • /
    • 1999
  • 본 연구의 목적은 CT장비로부터 얻어지는 단면 영상을 이용하여 재구성한 3차원 Voxel 정보를 기반으로 의료 시술 중 위험도가 높으며 장기간의 수술 훈련이 필요한 수술인 척추경나사 삽입술에 대한 모의 시술기를 개발하는 것이다. 모의 시술기의 입력은 환자의 환부에 대한 CT와 모의 시술을 해보고자 하는 의사 (사용자)의 입력 (경나사의 진입 위치와 각도)이 되며 출력은 의사들이 시술장에서 받을 수 있는 유일한 방법인 Voxel데이터로부터 재생성된 X-Ray이미지, 혹은 C-Arm의 동영상이며, 최종 결과 출력은 나사못이 삽입된 재구성 CT 이미지들과 3차원 정보를 볼 수 있는 Image Based Rendering의 Image data set이 된다. 본 연구에서는 각 시각화 부분의 특성을 고려하여 direct volume projection, surface modeling, 그리고 최근 많은 관심을 받고 있는 Image Based Rendering 기법을 intergrate하여 사용하였으며 각 시각화 모듈의 초고속 정보 통신망에서의 정보 교환에 대한 방법론에 대해 다루고 있다.

  • PDF

Closed Reduction of Zygomatic Arch Fracture with Intraoperative Mobile Computed Tomography Scan (관골궁 골절의 정복 시 술중 이동식 CT의 유용성)

  • Kim, Myung-Good;Noh, Yong-Joon;Lee, Hoon-Young;Kim, Min-Ho;Lee, Sin-Chul
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.91-94
    • /
    • 2010
  • Purpose: The purpose of this study is to describe the usefulness of intraoperative mobile CT scans in the reduction of zygomatic arch fracture. Method: Two patients with zygomatic arch fractures were selected who were indications of closed reduction by Gilles' approach. After the reduction was done in the operating room with zygomatic arch elevator, intraoperative CT scan was done to check the extent of reduction. Additional reduction was performed according to the obtained images from the intraoperative mobile CT scan. Examination of the preoperative CT, intraoperative CT after the reduction, and postoperative plain X-ray films were done for documentation and analysis. Results: Reduction was carried out successfully to the patients without any complications. Both patients were satisfied with the postoperative cosmetic and functional outcome. Revisional surgery was not necessary during the 6 months follow up. Conclusion: The advantage of this method is that it is easier to obtain three dimensional relationships of the fracture site. Furthermore, the operator is less exposed to radiation hazards compared to other methods that obtain intraoperative images such as the C-arm. In conclusion, intraoperative mobile CT scan can be a useful surgical aid in the reduction of zygomatic arch fractures.

The Usefulness of the Abdominal Computerized Tomography for the Diagnosis of Childhood Obesity and Its Correlation with Various Parameters of Obesity (소아 복부비만 진단을 위한 복부 전산화 단층 촬영의 유용성과 여러 지표와의 상관성 연구)

  • Shim, Yoon Hee;Cho, Su Jin;Rhyu, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1082-1089
    • /
    • 2005
  • Purpose : Abdominal obesity is encountered as a risk factor for cardiovascular diseases. However, the anthropometric cut-off value to estimate the cardiovascular risk, has not been suggested. This study was designed to find the relationship between the abdominal fat and various parameters of obesity to find the cardiovascular risk factors related to abdominal obesity and to establish practical methods to measure them. Methods : Twenty seven obese Korean adolescents of moderate to severe degree and 22 healthy adolescents were enrolled. The body mass index(BMI), arm circumference and skinfold thickness were measured. Furthermore, blood lipid, sugar, insulin and four different cytokines' levels were checked and the distribution of body composition was measured by bioelectrical impedance analysis. The subcutaneous and intra-abdominal fat thickness by abdominal ultrasonography(US) and the total and intra-abdominal fat area by abdominal computerized tomography(CT) were measured in the obese group. Results : The most accurate method to measure abdominal fat in children is abdominal CT and the fat mass measured by bioelectrical impedance was strongly correlated with it(r=0.954). It was also correlated with arm circumference, fat thickness measured by abdominal US, BMI, aspartate aminotransferase(AST), alanine aminotransferase(ALT) and triglyceride level. Conclusion : Abdominal CT is the most accurate method to measure intra-abdominal fat, and it can be replaced by abdominal US for cost effectiveness. The screening methods that can be used at school or in outpatient basis include bioelectrical impedance, waist/hip ratio, and arm circumference. The cardiovascular risk factors include leptin, triglyceride and insulin level.

Langerhans Cell Histiocytosis Causing Cervical Myelopathy in a Child

  • Jang, Kun-Soo;Jung, Youn-Young;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.6
    • /
    • pp.458-460
    • /
    • 2010
  • Langerhans cell histiocytosis (LCH), a disorder of the phagocytic system, is a rare condition. Moreover, spinal involvement causing myelopathy is even rare and unusual. Here, we report a case of atypical LCH causing myelopathy, which was subsequently treated by corpectemy and fusion. A 5-year-old boy presented with 3 weeks of severe neck pain and limited neck movement accompanying right arm motor weakness. CT scans revealed destruction of C7 body and magnetic resonance imaging showed a tumoral process at C7 with cord compression. Interbody fusion using cervical mesh packed by autologus iliac bone was performed. Pathological examination confirmed the diagnosis of LCH. After the surgery, the boy recovered from radiating pain and motor weakness of right arm. Despite the rarity of the LCH in the cervical spine, it is necessary to maintain our awareness of this condition. When neurologic deficits are present, operative treatment should be considered.

Double Extra-anatomic Bypasses in Upper and Lower Extremities - A Report of Case - (이중성 비해부학적 우회술 치험 1례)

  • 이신영
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.330-336
    • /
    • 1989
  • The patient was 47-year-old male who had suffered from aphasia and hemiplegia of the right side, but mental state was alert. On physical examination, BP was 130/80 mmHg in the right arm, but not checked in the left arm. The pulses of the left common carotid, brachial, and radial arteries were not palpable. The pulses of the right femoral, popliteal, and dorsalis pedis arteries were weakly palpable. Brain CT Scan revealed cerebral infarction of the left hemisphere. Aortogram showed occlusion of the left common carotid, and the right internal carotid and common iliac arteries. Subclavian steal phenomena were observed in the delayed aortogram. Double extra-anatomic bypasses; Axillo-Axillar bypass and Femora-Femoral bypass, were performed in the local anesthesia at two stages, because of risk of major operation under general anesthesia. Postoperatively, all pulses except for pulse of the left common carotid artery were equally palpable. On discharge, the hemiplegia of the right side was improved and able to walk with assistance.

  • PDF

Gastrointestinal Adverse Effects in Advanced Colorectal Carcinoma Patients Treated with Different Schedules of FOLFOX

  • Bano, Nusrat;Najam, Rahila;Qazi, Faaiza;Mateen, Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8089-8093
    • /
    • 2014
  • Background: To assess the frequency and severity of gastrointestinal adverse effects in advanced colorectal carcinoma patients treated with four different schedules of FOLFOX. Materials and Methods: Patients (median age 61 years) who underwent surgery were included in the study. All had measureable disease at CT scan, ultrasonography or clinical examination. Toxicity was graded on a scale of 1-5 according to the general grade definition of CTC v2.0. The severity of adverse effects (Grade 3 and 4) assessed in each treatment arm was compared. Results: Differences between the incidence rates of 3 and 4 toxicity and all grades of toxicity for all parameters in GI toxicity were very highly significant (p<0.001). Severe gastrointestinal symptoms of toxicity were noted with FOLFOX7 (oxaliplatin $130mg/m^2$). Grade 3 diarrhea was reported in 25% patients and grade 4 diarrhea in 4% in the FOLFOX7 treatment arm. Grade 2 vomiting was very frequently reported in the FOLFOX4 treatment arm (oxaliplatin $85mg/m^2$). Grade 2 stomatitis was reported in 42% patients treated with mFOLFOX6 (oxaliplatin $100mg/m^2$). Differences in the incidence rate of nausea, diarrhea and stomatitis among all treatment arms of FOLFOX were significant (p<0.05). Conclusions: Severe diarrhea is associated with FOLFOX7 treatment. No grade 3 or 4 GI toxicity was reported in patients of the mFOLFOX6 arm.

Three-dimensional intraoperative computed tomography imaging for zygomatic fracture repair

  • Peleg, Oren;Ianculovici, Clariel;Shuster, Amir;Mijiritsky, Eitan;Oz, Itay;Kleinman, Shlomi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.5
    • /
    • pp.382-387
    • /
    • 2021
  • Objectives: Zygomatic complex (ZMC) fractures comprise up to 40% of all facial fractures. Misaligned bone fragments and misplaced fixation hardware traditionally detected postoperatively on plain radiographs of the skull might require re-operation. The intraoperative O-Arm (Medtronic, USA) is a three-dimensional (3D) computed tomographic imaging system. Materials and Methods: This retrospective single-center study evaluated the utility of O-Arm scanning during corrective surgeries for ZMC and zygomatic arch (ZA) fractures from 2018 to 2020. Three females and 16 males (mean age, 31.52 years; range, 22-48 years) were included. Fracture instability (n=6) and facial deformity (n=15) were the most frequent indications for intraoperative 3D O-Arm scan. Results: The images demonstrated that all fracture lines were properly reduced and fixed. Another scan performed at the end of the fixation or reduction stage, however, revealed suboptimal results in five of the 19 cases, and further reduction and fixation of the fracture lines were required. Conclusion: Implementation of an intraoperative O-Arm system in ZMC and ZA fracture surgeries assists in obtaining predictable and accurate results and obviates the need for revision surgeries. The device should be considered for precise operations such as ZMC fracture repairs.

Quality Assessment for Elbow CT scan by positioning and respiratory control (팔꿈치관절 CT검사에서 환자 자세 및 호흡에 따른 화질평가)

  • Lim, Jong-Chun;Park, Sang-Hyun;Lee, In-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.110-114
    • /
    • 2017
  • Because the arm can't be sutured due to fracture during a elbow CT scan, a CT scan is proceeded in a state of abdomen and L-spire are overlapped which beam hardening artifact is done many times, and it often lowers the quality of elbow CT images. So there are many difficulties in reading and due to increase in radiation dose from it, the number of patient's exposure keeps increasing. In this research, it plans to improve the quality of the images by avoiding overlap with abdomen, and increasing the number of photon overlapped with lung field which the line attenuation is relatively small. The way of experiment is based on patient's right elbow and place him as head first position, then place his elbow at L2-3 level in supine position, turn about 30 degrees to the left in non-control breathing and in supine position, and compared with full inspiration after overlapping with lung. After figuring out the average value and standard deviation data using Image J program 5 times each for 16, 128 channels, the evaluation is proceeded by measuring each of CNR, MSR are statistically analyzed using SPSS program. Therefore, through positioning and inspiration during elbow CT scan, the way of inspection minimized the exposure radiation dose, and seems to be meaningful in a way to improve the quality of the images.