• 제목/요약/키워드: arcing frequency

검색결과 25건 처리시간 0.039초

전기저항용접의 파형제어에 관한 기초연구 (Preliminery study of waveform control in ERW process)

  • 조민현;김동철;강문진;은성수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.32-32
    • /
    • 2009
  • Electric Resistance Welding (ERW) process is the most efficient process to manufacture the linepipe. To develop the high performance ERW linepipe using the high strength and the high alloy steels, the modulation of input power waveform such as sinusoidal waveform is introduced because the conventional ERW technology is not sufficient enough to produce the high quality linepipe due to its strength and high alloy contents (high Ceq). In this article, the material used for the experiment was API X60 with 8.2mm thickness, and ERW simulator at POSCO was used to develop a waveform control system for the power modulation. The frequency of power modulation was varied from 50Hz to 150Hz with the fixed amplitude of ${\pm}2%$ power. The non-modulated power input and the modulated power input cases are conducted to demonstrate the variation of the narrow gap length and the arcing frequency due to power modulation. From results of the non-modulated power input case, the excessive power causes the longer narrow gap length and the low arcing frequency due to the large heat input and the strong electro magnetic force that increase the weld defect. On the contrary, the small narrow gap length and the high arcing frequency reduce the weld defect. After modulating the power input with 50Hz and 100Hz at the fixed power, the arcing frequency increases, but the narrow gap length does not change much. The high arcing frequency prevents the formation of weld defect because the sweeping frequently cleans the oxides on the narrow gap edges. As a result, the manufacturing window can be expanded by the power modulation that provides the stable ERW process for the quality improvement of the linepipe made from the high strength/high alloy steels.

  • PDF

저압배선계통에서 직렬아크의 검출에 관한 연구 (A Study on the Series Arc Detection in Low-voltage Wiring Systems)

  • 김일권;박대원;최수연;박찬용;김황국;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

직렬아크 검출 알고리즘에 관한 연구 (A Study on the Series Arc Detection Algorithm)

  • 김일권;박대원;최수연;박찬용;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1433-1437
    • /
    • 2007
  • This paper describes the detection algorithm which can distinguish series arcing signal from voltage harmonics or noises produced by the operation of non-linear loads. A high pass filter with the cutoff frequency of 3 kHz is designed and it can attenuate power frequency signal to 80 dB. Series arcing phenomena is simulated to an incandescent lamp controlled by a dimmer. From the experimental results, it is confirmed that the amplitude of the filter output voltage varies at random during series arcing but the signal generated by non-linear loads appears on a regular basis. We proposed a series arcing detection algorithm using the chaotic nature of voltage signal.

  • PDF

병렬아크에 대한 누전차단기의 트립특성 분석 (Analysis of Tripping Characteristics of Earth Leakage Circuit Breakers against Parallel Arcing)

  • 김일권;박대원;최수연;조영진;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.478-479
    • /
    • 2007
  • Many electrical fires are occurred by leakage currents and sparks generated by a short circuit. Earth leakage circuit breakers (ELCBs) should be tripped at the moment of the faults mentioned above. In this paper, we described the tripping characteristics of ELCBs against parallel arcing faults. A diesel engine generator with the capacity of 375 kVA source was adopted to provide enough large current when a parallel arcing occurred. The experimental results showed that most ELCBs we experimented were not tripped against short-duration pulse currents produced by parallel arcing because the ELCBs are designed to be tripped by a large current with long duration similar to power frequency.

  • PDF

대역통과필터를 이용한 직렬아크 검출에 관한 연구 (A Study on Series Arc Detection Using Band-pass Filters)

  • 김일권;김진수;박건우;김광순;김영일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1345-1347
    • /
    • 2008
  • This paper described a method of determining whether arcing is present in a low-voltage wiring system. We simulated the series arcing that generated in electrical loads and fabricated a arc detection module which can discriminate between normal and arcing state. The module consists of a high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage and an active band-pass filter with a frequency of 4 kHz ${\sim}$ 8 kHz to detect series arc signals only. We tested an Incandescent lamp that was controlled by a dimmer and analysed. The module consists of a high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a frequency of 4 kHz to detect series arc signals only. From the experimental results, we could detect series arc signals without an influence of non-linear loads.

  • PDF

MAG용접의 Arc안정성에 미치는 Si의 영향 (Effect of Si on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제16권6호
    • /
    • pp.52-58
    • /
    • 1998
  • The effect of Si content in welding wires on th arc stability was investigate, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing Si content, average arcing time and average short circuit time were increased. Therefore, droplet transfer frequency was decreased, due to the increase of arcing time and peak current at the moment of arc-reiginition was increased, due to the increase of short circuit time. In the region of spray transfer, the fluctuations of arc current and arc voltage was the most stable in wire with Si content of about 00.60 wt.%.

  • PDF

MAG용접의 Arc안정성에 미치는 S의 영향 (Effect of S on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.55-61
    • /
    • 1999
  • The effect of S content in welding wires on the arc stability was investigated, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing S content, average arcing time and average short circuit time were decreased. Therefore, droplet transfer frequency was increased, due to the reduction of arcing time and peak current at the moment of arc-reiginition was decreased, due to the decrease of short circuit time. In the region of spray transfer, the fluctuation degree of arc current and arc voltage became more stable, with increasing S content.

  • PDF

$CO_2$용접시 Spatter발생에 미치는 Ti의 영향 (Effect of Ti on Spatter Generation of $CO_2$Welding)

  • 안영호;이종봉;방국수;엄동석
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.106-112
    • /
    • 1996
  • The effects of Ti addition in welding wire on the spatter generation and the droplet transfer phenomena were investigated. With increasing Ti content the spattering rate was decreased but the ratio of large size spatter (D $\geq$ 1. 0mm) was increased in both short circuit and globular transfer mode of $CO_2$welding. In short circuit transfer region, the arcing time was increased and the droplet transfer frequency was decreased with increasing Ti content In globular transfer region, the transition current and voltage to globular transfer was lowered and the welding condition region for stable globular transfer was widened with increasing Ti content.

  • PDF

직렬아크현상의 검출기술 및 장치 (Detection Technique and Device of Series Arcing Phenomena)

  • 지홍근;정광석;박대원;길경석;서동환;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.332-338
    • /
    • 2010
  • 전력계통에서 아크현상이 원인이 되는 전기화재는 전기제품의 사용증가에 따라 급증하고 있으나, 이들 사고를 방지할 수 있는 확립된 방법은 없다. 이들 배경에서 본 논문은 공기조화기에서 직렬아크 검출 기술과 장치에 대한 실험적 결과에 대해 기술하였다. 공기조화기의 불완전한 접속부에서 발생하는 직렬아크를 모의하고, 주파수 스펙트럼을 FFT로 분석한 결과, 190 kHz~250 kHz와 900 kHz~1.6 MHz 에 존재함을 알 수 있었다. 저역차단주파수가 170 kHz이며 60 Hz를 176 dB까지 감쇄시킬 수 있는 아크검출 및 파형정형 회로를 설계하였다. 또한 스위치 조작, 인버터 운전 및 서지 등에 의해 발생하는 노이즈로부터 직렬아크신호를 분리할 수 있는 알고리즘을 제안하였다. 적용실험은 UL1699에 규정 되어있는 아크발생장치를 이용하여 여러 형태의 공기조화기에서 수행되었으며, 99 %이상 검출능력을 나타내었다.

전력계통의 고임피던스 고장 검출 기법에 관한 연구 (A Study on High Fault Detection In Power System)

  • 임화영;유창완;고재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권1호
    • /
    • pp.16-21
    • /
    • 1999
  • The analysis of distribution line faults is essential to the proper protections of the power system. A high impedance fault test, which was carried in Korean electric power systems, it was found that a arcing phenomenon occurred during the high level portion of conductor voltage in each cycle. In this paper, we propose a new method for detection of high impedance faults, which uses the arcing fault current difference during high voltage and low voltage portion of conductor voltage waveform. To extract this difference, we diveded one cycle fault current into equal spanned four data windows according to the magnitude of voltage waveform and applied fast fourier transform(FFT) to each data window. The frequency spectrum of current wavefrom in each portion are used as the inputs of neural network and is trained to detect high impedance faults. The proposed method shows improved accuracy when applied to staged fault data and fault-like load.

  • PDF