• Title/Summary/Keyword: arc simulation

Search Result 422, Processing Time 0.025 seconds

Numerical Study of SF6 arc with Copper Contamination

  • Liau Vui-Kien;Lee Byeong-Yoon;Song Ki-Dong;Park Kyong-Yop
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.233-241
    • /
    • 2005
  • The present model of a SF6 arc accounts for the copper vapour contamination from the electrodes inside a Laval nozzle of a circuit breaker. Steady state simulations have been done for the arc with electrode gap of 60mm and DC electric current of 500A, 1000A and 1500A for both cases with and without copper contamination. The effects of electrode polarity are considered for the arc current of 1000A. It was found out that evaporation of copper from the anode results in a cooling of the arc in a region close to the electrodes. The electrical potential across the electrodes is not sensitive to the presence of copper vapour, typically less than $4\%$ difference. Transient analysis has been done in order to obtain the arc properties at current zero. The arc current is increased linearly from -1000 to 0A when the upstream electrode is cathode with constant dI/dt of $27.0A/{\mu}s$ (or decreased linearly from 1000 to 0A when upstream electrode is anode). It has been predicted that the presence of copper vapour reduces the interruption capability of the breaker.

Spatial and Temporal Behavior of Arc with Magnetic Field (자계가 인가된 아크의 공간적, 시간적 거동)

  • Choi, Won-Joon;Kang, Jin;Choi, Seung-Kil;Ko, Hwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1809-1811
    • /
    • 1998
  • Axial magnetic field restrains arc diffusion that appear at cutting off fault current in vacuum interrupter(VI). In this study, spatial and temporal behavior simulation of arc is carried out for various axial magnetic field. Also the results of this simulation show that axial magnetic field controls and helps to extinguish arcs. This study can be applied to design and analysis of VI. Dymo theory that is not considered in this study will be considered latter.

  • PDF

Analysis of Dielectric Breakdown of Hot SF6 Gas in a Gas Circuit Breaker

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Song, Ki-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.264-269
    • /
    • 2010
  • This paper presents the analysis of the dielectric characteristics of a hot $SF_6$ gas in a gas circuit breaker. Hot gas flow is analyzed using the FVFLIC method considering the moving boundary, material properties of real $SF_6$ gas, and arc plasma. In the arc model, the re-absorption of the emitted radiation is approximated with the boundary source layer where the re-absorbed radiation energy is input as an energy source term in the energy conservation equation. The breakdown criterion of a hot gas is predicted using the critical electric field as a function of temperature and pressure. To validate the simulation method, breakdown voltage for a 145kV 40kA circuit breaker was measured for various conditions. Consistent results between the simulation and experiment were confirmed.

A Study On Power Factor Correction of SMAW(shielded metal-arc welding) Using Single Phase AC/DC Boost Converter (단상 AC/DC 승압형 컨버터를 이용한 피복 아크 용접기 역률 개선에 관한 연구)

  • Yu Y. J.;Kim L. H.;Kim J. H.;Won C. Y.;Kim Y. R.;Lee S. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.556-559
    • /
    • 2001
  • In this paper, we proposed AC/DC boost converter to improve input current harmonic reduction in SMAW(shielded metal-arc welding). The proposed harmonic reduction with the boost converter design and the UC2854 integrated circuit which controls the converter, The topology of welding power supply is made of a pair of boost converter and welder half-bridge IGBT inverter. The voltage arc is modeled by a variable resistance in series with a voltage source. The results has been confirmed by PSIM simulation tool. The simulation results show that input at current is nearly sinusoidal with low harmonic contents and sinusoidal input current waveform at high power factor.

  • PDF

Characteristics of Interruption Ability in DC Circuit Breaker using Superconducting Coil (초전도 코일을 이용한 DC 회로 차단기의 차단 능력 특성)

  • Jeong, In-Sung;Choi, Hye-Won;Youn, Jeong-Il;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.215-219
    • /
    • 2019
  • Development of DC interruption technology is being studied actively for enhanced DC grid reliability and stability. In this study, coil type superconductor DC circuit breaker was proposed as DC interruption. It is integration technology that combined current-limiting technique using superconductor and cut-off technique using mechanical DC circuit breaker. Superconductor was applied to the coil type. In simulation, Mayr arc model was applied to realize the arc characteristic in the mechanical DC circuit breaker. PSCAD/EMTDC had used to model and perform the simulation. To find out the protection range of coil type superconductor DCCB, the working operation have analyzed based on the rated voltage of DCCB. The results confirmed that, according to apply the limiting device, the protection range was increased in twice. Therefore, the probability of failure of interruption has lowered significantly.

Design of an Antireflection Coating for High-efficiency Superconducting Nanowire Single-photon Detectors

  • Choi, Jiman;Choi, Gahyun;Lee, Sun Kyung;Park, Kibog;Song, Woon;Lee, Dong-Hoon;Chong, Yonuk
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.375-383
    • /
    • 2021
  • We present a simulation method to design antireflection coating (ARCs) for fiber-coupled superconducting nanowire single-photon detectors. Using a finite-element method, the absorptance of the nanowire is calculated for a defined unit-cell structure consisting of a fiber, ARC layer, nanowire absorber, distributed Bragg reflector (DBR) mirror, and air gap. We develop a method to evaluate the uncertainty in absorptance due to the uncontrollable parameter of air-gap distance. The validity of the simulation method is tested by comparison to an experimental realization for a case of single-layer ARC, which results in good agreement. We show finally a double-layer ARC design optimized for a system detection efficiency of higher than 95%, with a reduced uncertainty due to the air-gap distance.

A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the Electric Arc Furnace Loads (시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.9-17
    • /
    • 2006
  • Large steel industries have nonlinear loads such as electric arc furnaces. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time-varying harmonics. Harmonic simulations are performed to evaluate the harmonic voltage and current distortions throughout the system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519 and harmonic simulation for the time-varying harmonics. The EDSA program was used as a simulation tool for the case study.

Aerodynamic performance of Modified Sonic Arc Airfoil (수정 Sonic Arc 익형의 공력성능)

  • Lee, Jang-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.7
    • /
    • pp.581-585
    • /
    • 2007
  • Sonic arc airfoil derived from the TSD theory is modified to new airfoil shape and its aerodynamic performance in transonic flow is investigated. The numerical simulation using Euler equations for the modified sonic arc airfoil is performed. The numerical results are compared with the aerodynamic performance of NACA0012 airfoil, of supercritical airfoil, and of NACA64A210 airfoil. In the same free stream Mach number of transonic flow, the pressure drag of the modified sonic arc airfoil is smaller than that of NACA0012 airfoil and the lift-drag ratio of the modified sonic arc airfoil is much larger than that of NACA0012 airfoil. In the comparison of the drag-divergence Mach number of transonic flow, the drag-divergence Mach number of the modified sonic arc airfoil is larger than that of NACA64A210 airfoil but is smaller than that of supercritical airfoil.

ANALYSIS OF TRANSIENT TEMPERATURE DISTRIBUTION IN ROTATING ARC GMA ELDING BY CONSIDERING DROPLET DEFLECTION

  • Kim, Cheolhee;Na, Suck-Joo
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.763-768
    • /
    • 2002
  • This paper presents a mathematical model predicting the temperature distribution in rotating GMA welding. The bead width increases with rotation frequency at the same rotation diameter because the molten droplets are deflected by centrifugal force. The numerical solution is obtained by solving the transient three-dimensional heat conduction equation considering the heat input from the welding arc, cathode heating and molten droplets. Generally in GMA welding the heat input may be assumed as a normally distributed source, but the droplet deflection causes some changes in the heat input distribution. To estimate the heat flux distribution due to the molten droplet, the contact point where the droplet is transferred on the weld pool surface is calculated from the flight trajectory of the droplets under the arc plasma velocity field obtained from the arc plasma analysis. The numerical analysis shows a tendency of broadened bead width and shallow penetration depth with the increase of rotating frequency. The simulation results are in good agreement with those obtained by the experiments under various welding conditions.

  • PDF

Analysis of Hot Gas Flew Considering Arc-Flow Interaction (아크플라즈마와 유동간의 상호작용을 고려한 열가스 유동 해석)

  • Kim, Hong-Gyu;Park, Gyeong-Yeop;Bae, Chae-Yun;Jo, Gyeong-Yeon;Jeong, Hyeon-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.3
    • /
    • pp.107-115
    • /
    • 2002
  • This parer presents the analysis of hot gas flow in puffer-type circuit breakers using FVFLIC method. For the analysis of arc-flow interaction, the flow field is analyzed from the equations of conservation for mass, momentum and energy with the assumption of local thermodynamic equilibrium state. The arc is represented as the energy source term composed of ohmic heating and radiation term in the energy conservation equation. Ohmic heating is computed by the electric field analysis only within the conducting plasma region. An approximate radiation transport model is employed for the evaluation of emission and absorption of the radiation. The analysis method was applied to the real circuit breaker model and simulation results such as pressure rise and arc voltage were compared with the experimental ones.