• Title/Summary/Keyword: arc measure

검색결과 123건 처리시간 0.026초

펄스 TIG용접에서 필러 와이어 송급속도에 따른 아크압력 변동이 용입에 미치는 영향 (The Effects of the Arc Pressure Variation on the Penetration by the filler Wire Feed Rate in Pulsed TIG Welding)

  • 조상명;김진우
    • Journal of Welding and Joining
    • /
    • 제22권1호
    • /
    • pp.71-76
    • /
    • 2004
  • In the standpoint of the arc pressure, the effects of the filler wire feed rate on the penetration was investigated in this study. The pure Ar gas was used as a shield gas and the parameters investigated were the welding current and the filler wire feed rate. By making the experiment on the arc pressure, we could know that the arc pressure was fluctuated as the depth-into-arc of the tungsten rod. Instead of the filler wire, the tungsten rod was supplied into the molten pool to make this experiment. Because the filler wire melted in arc and then we couldn't measure the arc pressure. So, the tungsten rod - the highest melting point - was used. According to the depth-into-arc of the tungsten rod, the arc pressure could be measured by using the manometer. It was proved that the arc pressure got higher as the wire feed rate was slow. It is reported the arc pressure is proportion to welding voltage and the square of welding current. But, in the filler wire TIG welding, we could blow that arc pressure was fluctuated as the depth-into-arc of filler wire was changed. We could measure the arc pressure by the variation of the filler wire feed rate and could verify that it affected bead shape and penetration.

Thyristor Rectifier for DC Arc Furnace with Enhanced Arc Stability

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.498-499
    • /
    • 2011
  • In this paper, the fundamental features of the arc stability DC arc furnace have been investigated, from the converter point of view. To compare of measurement arc data from DC arc furnace and the advanced arc simulations of magneto-hydrodynamics (MHD) and the well known Cassie-Mayr arc model have been extensively used. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. The arc simulation predicted the arc voltage for different currents with the accuracy which satisfies engineering requirements. It has been shown that the arc current steepness at current zero determines the arc stability, and the associated peak arc resistance can be used as its quantitative measure. Based on the presented insight into the DC arc stability, a converter topology solution which realizes an optimal arc stability has been proposed. The main results presented in this paper provide a design guideline for the future DC arc furnace converter topology developments.

  • PDF

A Study on Arc Force Sensor for a Robotic Welding Control System

  • Son, Joon-Sik;Kim, Ill-Soo;Choi, Seung-Gap;Kueon, Yeong-Seob;Lee, Duk-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.128.5-128
    • /
    • 2001
  • This paper presents investigation of an arc force sensor for a robotic welding control system. Arc force sensor is employed in this research to monitor the bead geometry of the arc welding process. Arc force sensor mounted at the end of the robot wrist was employed to measure the arc force applied to the weld. Experimental configuration for measurement of arc force was used to quantify the changes in the arc force distributions of the plate being welded. A relationship between the bead dimension and the arc force distributions was established. The sensor information was used to establish a relationship between welding current and arc force. Arc force sensor have shown to be one of the most sophisticated technique to monitor perturbations that occurred during robotic arc welding process.

  • PDF

연관 웹 페이지 검색을 위한 e-아크 랭킹 메저 (e-Cohesive Keyword based Arc Ranking Measure for Web Navigation)

  • 이우기;이병수
    • 한국정보과학회논문지:데이타베이스
    • /
    • 제36권1호
    • /
    • pp.22-29
    • /
    • 2009
  • 웹은 사용자에게 제품이나 정보를 제공할 수 있는 가장 커다란 매체로 성장하였으며, 또한 사용자에게는 필요 이상의 정보를 얻게 해주고 있다. 웹은 다량의 관련 정보들을 여러 웹 페이지들을 통해 표현하고 있으며, 현재 검색엔진들은 키워드들에 관련된 단일 페이지들만을 리스트화하여 보여주고 있다. 근본적으로 이러한 방법들로는 관련된 정보를 가지고 있는 페이지들의 쌍 및 연관된 뭔 페이지들의 집합을 구조화하여 제공할 수 없다. 웹은 하나의 웹 페이지에 모든 관련 정보를 담는 범위를 넘어 관련된 정보 페이지들을 하이퍼링크로 서로 연결한 일련의 정보로 인식되고 있다. 따라서 본 논문에서는 새로운 링크 가중치 기반 검색 기법으로서 e-아크 메저에 관하여 제안하고자 하며, 이는 사용자가 입력한 키워드들과 관련된 페이지의 집합을 웹 사이트 안에서 찾아내는 연관 검색에 효과적이라는 것을 보이고, 실험을 통해 기존의 메저들 보다 그 효과성을 우월하다는 점을 입증하였다.

가스차단기내 아크의 복사에너지 측정에 관한 연구 (Study on the Measurement of Radiation Energy of the Arc in GCBs)

  • 송기동;오연호;정진교;조용성
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2122-2126
    • /
    • 2007
  • A special PM-Tube(Photo Multiplier Tube) that is using the photoelectric effect has been designed and manufactured to measure the radiation energy of arc in a gas circuit breaker(GCB). The PM-Tube, LLG(liquid light guides), ND(neutral density) filter, and a model gas circuit breaker have been combined for the reception and the transmission of the light and a simplified synthetic test facility with the arc energy measuring system has been established. In the case of $SF_6$ gas pressure $5kg.f/cm^2$ and arc length 20mm, the radiation energy increases with the arc current but it tend to be saturated in the above 20kA. Under the arc current 20kA, the total radiation energy has the biggest value around 8kA and was not exceeded 40% of the total arc energy.

TIG 용접에서의 실드 가스 혼합비에 따른 아크 압력분포 특성 (The Characteristics on Arc Pressure Distribution of TIG Welding with Shield Gas Mixing Ratio)

  • 오동수;김영식;조상명
    • Journal of Welding and Joining
    • /
    • 제23권1호
    • /
    • pp.41-47
    • /
    • 2005
  • Arc pressure is one of important factors in understanding physical arc phenomena. Especially it affects on the penetration, size and shape of TIG welding. Some researches were reported on the effect of arc pressure in low and middle current region. But there are not any research in high current region. The purpose of this study is to investigate the arc pressure distribution with mixing ratio of shield gas such as Ar and He gases. A Cu block with water cooling was specifically designed and used as an anode electrode in order to measure the arc pressure in high current region. Then, the arc pressure distribution was measured with change in welding current and mixing ratio of shield gases. The arc force was obtained by numerically integrating the measured results. As the results, it was shown that the arc pressure was concentrated at the central part of the arc in middle and high current regions when a pure Ar gas was used. In case of Ar + He mixing gas, the arc pressure was much lower than that of pure Ar gas. In addition, it was widely distributed to radial direction.

로봇 아크용접 공정제어를 위한 새로운 알고리즘 (A New Algorithm for Control of Robotic Arc Welding Process)

  • 박요창;김일수;박창언;김정식;허업;정영재
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2001년도 춘계학술발표대회 개요집
    • /
    • pp.65-68
    • /
    • 2001
  • The application of a feedback control system in robotic arc welding is becoming more and more demanding than ever before. This requirement arises from the fact that robotic arc welding process needs no manual operator to monitor and manipulate the process parameters and hence a means of controlling the quality of the robotic arc welding process becomes apparent. Arc force sensor employed in this research to monitor the bead geometry of the arc welding process, A relationship between the bead dimension and the arc force distributions was established. Experimental configuration for measurement of arc force was used to quantify the changes in the arc force distributions of the plate being welded. Arc force sensor mounted at the end of the robot wrist was employed to measure the arc force applied to the weld. The sensor information was the used to establish a relationship between welding current and arc force. Arc force sensor have shown to be on of the most sophisticated technique to monitor perturbations that occurred during arc welding process.

  • PDF

GMA용접공정의 실시간 모니터링을 위한 표면온도 측정 (Measurement of Surface Temperature for Real Time Monitoring of the GMA Welding Processes)

  • 부광석;조형석
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1994년도 특별강연 및 추계학술발표 개요집
    • /
    • pp.111-114
    • /
    • 1994
  • This paper describes a method to measure a weldment surface temperature for estimating variations of the weld pool size in the gas metal arc(GMA) welding processes. An Infrared sensing system is designed to measure the radiation emitted from the top surface of the weldment, The interference effect of the electric arc to the measurement is rejected by detecting the low peaks of the noisy signal. An optimizing criterion, in which the correlation between the weld quality and the measured temperature is maximized, is also proposed to determine the optimal measurement location.

  • PDF

아크 플라즈마 유동에 삽입된 엔탈피 탐침의 동작특성 실험 (Experimental analysis on the characteristics of enthalpy probe immersed in arc plasma flow)

  • 서준호;남준석;최성만;홍봉근;홍상희
    • 한국항공우주학회지
    • /
    • 제38권12호
    • /
    • pp.1240-1246
    • /
    • 2010
  • 내경 1.5 mm, 외경 4.8 mm를 갖는 엔탈피 탐침을 설계 제작하고, 17 kW급 비이송식 직류 아크히터로부터 나오는 고엔탈피 Ar 아크 플라즈마 유동의 중심축을 따라 삽입하면서 탐침 첨두가 파괴될 때까지 온도와 속도를 측정하였다. 이 실험으로부터, 설계된 엔탈피 탐침은 대기압 조건에서 최대 12,000 K 의 온도와 600 m/s 의 속도를 갖는 고엔탈피아크 플라즈마 유동장에 대해 탐침 첨두의 파괴 없이 동작할 수 있음을 관찰하였다. 탐침첨두에서 형성되는 비압축성 열경계층 및 열속 방정식으로부터 이 경우의 아크 플라즈마 유동은 약 ${\sim}5{\times}10^7\;W/m^2$의 열속 부하를 전달한 것으로 추측되었다. 이로부터, 설계된 엔탈피 탐침은 $0{\sim}5{\times}10^7\;W/m^2$의 열속 범위 내에서 다양한 형태의 아크히터로부터 발생되는 넓은 범위의 플라즈마 온도, 속도 및 농도를 동시에 측정할 수 있을 것으로 기대된다.

DC Arc Extinction Using External Magnetic Field in Switching Device

  • Cho Hyun-Kil;Lee Eun-Woong;Jeong Jong-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.306-311
    • /
    • 2005
  • In this paper, the electromagnetic force acting in the arc column of 3 different extinction units is compared with using the FEM (Finite Element Method) and the arc velocity is calculated by the drag force of the fluid mechanics. The experiment for breaking the arc current was performed in each model at 100 volts in order to measure the arcing time. The outcome was compared with the computing value. As a result, this paper proposes that the divided U-shaped grid is able to shorten arcing time and improve the electric performance. It also suggests a methodology for comparing and analyzing the result obtained by simulation and experiment.