• Title/Summary/Keyword: arc measure

Search Result 123, Processing Time 0.043 seconds

The Effects of the Arc Pressure Variation on the Penetration by the filler Wire Feed Rate in Pulsed TIG Welding (펄스 TIG용접에서 필러 와이어 송급속도에 따른 아크압력 변동이 용입에 미치는 영향)

  • 조상명;김진우
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2004
  • In the standpoint of the arc pressure, the effects of the filler wire feed rate on the penetration was investigated in this study. The pure Ar gas was used as a shield gas and the parameters investigated were the welding current and the filler wire feed rate. By making the experiment on the arc pressure, we could know that the arc pressure was fluctuated as the depth-into-arc of the tungsten rod. Instead of the filler wire, the tungsten rod was supplied into the molten pool to make this experiment. Because the filler wire melted in arc and then we couldn't measure the arc pressure. So, the tungsten rod - the highest melting point - was used. According to the depth-into-arc of the tungsten rod, the arc pressure could be measured by using the manometer. It was proved that the arc pressure got higher as the wire feed rate was slow. It is reported the arc pressure is proportion to welding voltage and the square of welding current. But, in the filler wire TIG welding, we could blow that arc pressure was fluctuated as the depth-into-arc of filler wire was changed. We could measure the arc pressure by the variation of the filler wire feed rate and could verify that it affected bead shape and penetration.

Thyristor Rectifier for DC Arc Furnace with Enhanced Arc Stability

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.498-499
    • /
    • 2011
  • In this paper, the fundamental features of the arc stability DC arc furnace have been investigated, from the converter point of view. To compare of measurement arc data from DC arc furnace and the advanced arc simulations of magneto-hydrodynamics (MHD) and the well known Cassie-Mayr arc model have been extensively used. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. The arc simulation predicted the arc voltage for different currents with the accuracy which satisfies engineering requirements. It has been shown that the arc current steepness at current zero determines the arc stability, and the associated peak arc resistance can be used as its quantitative measure. Based on the presented insight into the DC arc stability, a converter topology solution which realizes an optimal arc stability has been proposed. The main results presented in this paper provide a design guideline for the future DC arc furnace converter topology developments.

  • PDF

A Study on Arc Force Sensor for a Robotic Welding Control System

  • Son, Joon-Sik;Kim, Ill-Soo;Choi, Seung-Gap;Kueon, Yeong-Seob;Lee, Duk-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.128.5-128
    • /
    • 2001
  • This paper presents investigation of an arc force sensor for a robotic welding control system. Arc force sensor is employed in this research to monitor the bead geometry of the arc welding process. Arc force sensor mounted at the end of the robot wrist was employed to measure the arc force applied to the weld. Experimental configuration for measurement of arc force was used to quantify the changes in the arc force distributions of the plate being welded. A relationship between the bead dimension and the arc force distributions was established. The sensor information was used to establish a relationship between welding current and arc force. Arc force sensor have shown to be one of the most sophisticated technique to monitor perturbations that occurred during robotic arc welding process.

  • PDF

e-Cohesive Keyword based Arc Ranking Measure for Web Navigation (연관 웹 페이지 검색을 위한 e-아크 랭킹 메저)

  • Lee, Woo-Key;Lee, Byoung-Su
    • Journal of KIISE:Databases
    • /
    • v.36 no.1
    • /
    • pp.22-29
    • /
    • 2009
  • The World Wide Web has emerged as largest media which provides even a single user to market their products and publish desired information; on the other hand the user can access what kind of information abundantly enough as well. As a result web holds large amount of related information distributed over multiple web pages. The current search engines search for all the entered keywords in a single webpage and rank the resulting set of web pages as an answer to the user query. But this approach fails to retrieve the pair of web pages which contains more relevant information for users search. We introduce a new search paradigm which gives different weights to the query keywords according to their order of appearance. We propose a new arc weight measure that assigns more relevance to the pair of web pages with alternate keywords present so that the pair of web pages which contains related but distributed information can be presented to the user. Our measure proved to be effective on the similarity search in which the experimentation represented the e~arc ranking measure outperforming the conventional ones.

Study on the Measurement of Radiation Energy of the Arc in GCBs (가스차단기내 아크의 복사에너지 측정에 관한 연구)

  • Song, Ki-Dong;Oh, Yeon-Ho;Chong, Jin-Kyo;Cho, Young-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2122-2126
    • /
    • 2007
  • A special PM-Tube(Photo Multiplier Tube) that is using the photoelectric effect has been designed and manufactured to measure the radiation energy of arc in a gas circuit breaker(GCB). The PM-Tube, LLG(liquid light guides), ND(neutral density) filter, and a model gas circuit breaker have been combined for the reception and the transmission of the light and a simplified synthetic test facility with the arc energy measuring system has been established. In the case of $SF_6$ gas pressure $5kg.f/cm^2$ and arc length 20mm, the radiation energy increases with the arc current but it tend to be saturated in the above 20kA. Under the arc current 20kA, the total radiation energy has the biggest value around 8kA and was not exceeded 40% of the total arc energy.

The Characteristics on Arc Pressure Distribution of TIG Welding with Shield Gas Mixing Ratio (TIG 용접에서의 실드 가스 혼합비에 따른 아크 압력분포 특성)

  • Oh Dong-Soo;Kim Yeong-Sik;Cho Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.23 no.1
    • /
    • pp.41-47
    • /
    • 2005
  • Arc pressure is one of important factors in understanding physical arc phenomena. Especially it affects on the penetration, size and shape of TIG welding. Some researches were reported on the effect of arc pressure in low and middle current region. But there are not any research in high current region. The purpose of this study is to investigate the arc pressure distribution with mixing ratio of shield gas such as Ar and He gases. A Cu block with water cooling was specifically designed and used as an anode electrode in order to measure the arc pressure in high current region. Then, the arc pressure distribution was measured with change in welding current and mixing ratio of shield gases. The arc force was obtained by numerically integrating the measured results. As the results, it was shown that the arc pressure was concentrated at the central part of the arc in middle and high current regions when a pure Ar gas was used. In case of Ar + He mixing gas, the arc pressure was much lower than that of pure Ar gas. In addition, it was widely distributed to radial direction.

A New Algorithm for Control of Robotic Arc Welding Process (로봇 아크용접 공정제어를 위한 새로운 알고리즘)

  • Park, Yo-Chang;Kim, Il-Su;Park, Chang-Eon;Kim, Jung-Sik;Heo, Eop;Jung, Young-Jae
    • Proceedings of the KWS Conference
    • /
    • 2001.05a
    • /
    • pp.65-68
    • /
    • 2001
  • The application of a feedback control system in robotic arc welding is becoming more and more demanding than ever before. This requirement arises from the fact that robotic arc welding process needs no manual operator to monitor and manipulate the process parameters and hence a means of controlling the quality of the robotic arc welding process becomes apparent. Arc force sensor employed in this research to monitor the bead geometry of the arc welding process, A relationship between the bead dimension and the arc force distributions was established. Experimental configuration for measurement of arc force was used to quantify the changes in the arc force distributions of the plate being welded. Arc force sensor mounted at the end of the robot wrist was employed to measure the arc force applied to the weld. The sensor information was the used to establish a relationship between welding current and arc force. Arc force sensor have shown to be on of the most sophisticated technique to monitor perturbations that occurred during arc welding process.

  • PDF

Measurement of Surface Temperature for Real Time Monitoring of the GMA Welding Processes (GMA용접공정의 실시간 모니터링을 위한 표면온도 측정)

  • 부광석;조형석
    • Proceedings of the KWS Conference
    • /
    • 1994.10a
    • /
    • pp.111-114
    • /
    • 1994
  • This paper describes a method to measure a weldment surface temperature for estimating variations of the weld pool size in the gas metal arc(GMA) welding processes. An Infrared sensing system is designed to measure the radiation emitted from the top surface of the weldment, The interference effect of the electric arc to the measurement is rejected by detecting the low peaks of the noisy signal. An optimizing criterion, in which the correlation between the weld quality and the measured temperature is maximized, is also proposed to determine the optimal measurement location.

  • PDF

Experimental analysis on the characteristics of enthalpy probe immersed in arc plasma flow (아크 플라즈마 유동에 삽입된 엔탈피 탐침의 동작특성 실험)

  • Seo, Jun-Ho;Nam, Jun-Seok;Choi, Seong-Man;Hong, Bong-Gun;Hong, Sang-Hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1240-1246
    • /
    • 2010
  • Enthalpy probe with the inner and outer diameters of 1.5 mm and 4.8 mm, respectively, is designed and used to measure the temperatures and velocities along the centerline of Ar arc plasma flow until the probe was destroyed. For this purpose, Ar arc plasma flow is generated by non-transferred type DC arc heater with the power level of 17 kW. From this experiment, it is shown that the designed enthalpy probe can measure the temperature and velocity of arc plasma flow up to 12,000 K and 600 m/s, respectively, without destroy of probe tip. In this extreme case, the arc plasma flow is calculated to transfer the heat flux of ${\sim}5{\times}10^7\;W/m^2$ to the probe based on the heat and thermal boundary equations near the forward stagnation point of a body immersed in arc plasma flow. Consequently, the designed enthalpy probe can measure the wide ranges of plasma temperatures, velocities and concentrations simultaneously, which are generated by various types of arc heaters within the heat flux ranges of $0{\sim}5{\times}10^7\;W/m^2$ on the probe tip.

DC Arc Extinction Using External Magnetic Field in Switching Device

  • Cho Hyun-Kil;Lee Eun-Woong;Jeong Jong-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.306-311
    • /
    • 2005
  • In this paper, the electromagnetic force acting in the arc column of 3 different extinction units is compared with using the FEM (Finite Element Method) and the arc velocity is calculated by the drag force of the fluid mechanics. The experiment for breaking the arc current was performed in each model at 100 volts in order to measure the arcing time. The outcome was compared with the computing value. As a result, this paper proposes that the divided U-shaped grid is able to shorten arcing time and improve the electric performance. It also suggests a methodology for comparing and analyzing the result obtained by simulation and experiment.