• 제목/요약/키워드: aquifer characteristics

검색결과 207건 처리시간 0.026초

국가지하수 관측망의 양수시험 자료 해석을 통한 대수층 특성 분석

  • 전선금;구민호;김용제;강인옥
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.487-491
    • /
    • 2004
  • For tile hydrogeological data of the National Groundwater Monitoring Wells(NGMW), a statistical analysis is made to reveal aquifer characteristics of the country. Results of the pumping and recovery test are classified into 4~5 types by the pattern of drawdown and residual drawdown curves. The analysis of aquifer characteristics shows that the hydraulic conductivity of alluvial aquifers is greater than that of fractured-rock aquifers. The hydraulic conductivity of alluvial aquifers slightly increases as the distance to the discharge area decreases. 77.5% of the NGMWs, where the distance to the discharge area is more than 100m, shows the constant head boundary. This result suggests that the fractured and the alluvial aquifers are fairly interconnected, and water can be supplied from one aquifer to tile other where pumping tests are performed. It is analyzed that the wells showing the impermeable boundary are influenced by small scale of aquifers, poor aquifer transmissivities, and impermeable layers.

  • PDF

Aquifer Characterization in Cheon-an area by using long-term groundwater-level monitoring data

  • 원이정;김형수;구민호;김덕근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.565-569
    • /
    • 2003
  • One-year-long groundwater-level data have been collected from 18 wells in Cheon-an area. The result of barometric efficiency, autocorrelation, cross-correlation and statistical distribution evaluated from the measurement data shows that groundwater-level measurements from observation wells are the principal source of information about aquifer characteristics. Data from WA-2 has high barometric efficiency as well as steady decreasing auto-correlation coefficient, which means nonleaky confined aquifer, Most aquifers in this study show the unconfined properties so that barometric efficiencies are mostly low and the coefficients of cross-correlation between groundwater-level and precipitation are commonly high. This study showed that the long-term groundwater-level monitoring data without artificial stress such as pumping would give accurate information about aquifer characteristics.

  • PDF

포항지역 지열수의 수리지구화학적 특성

  • 고동찬;염병우;하규철;송윤호
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.453-454
    • /
    • 2004
  • Hydrogeochemical and isotopic characteristics were investigated for groundwater of Tertiary basin in southeastern part of Korea where deep drilling is in progress for geothermal investigation. According to geology, aquifer was distinguished as alluvial, tertiary sedimentary bedrock (bedrock groundwater), and fractured volcanic rock (deep groundwater). Groundwater of each aquifer is distinctively separated in Eh-pH conditions and concentrations of Cl, F, B and HCO$_3$. Deep groundwater has very low level 3H and 14C whereas alluvial groundwater has those of recent precipitation level. However one of deep groundwater show mixed characteristics in terms of hydrochemistry which indicates effect of pumping. Deep groundwater have temperature of 38 to 43$^{\circ}C$ whereas bedrock and alluvial groundwater have temperature less than 2$0^{\circ}C$. Fractured basement rock aquifer has different hydrogeologicalsetting from bedrock and alluvial aquifer considering hydrogeochemical and isotopic characteristics, and temperature.

  • PDF

대수층 축열 에너지 활용 모델의 온도 분포 시뮬레이션 연구 (A study of the simulation of thermal distribution in an aquifer thermal energy storage utilization model)

  • 심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.697-700
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop an ATES system which has certain hydrogeological characteristics, understanding of the thermo hydraulic processes of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermo hydraulic transfer for heat storage is simulated using FEFLOW according to two sets of pumping and waste water reinjection scenarios of heat pump operation in a two layered confined aquifer. In the first set of model, the movement of the thermal front and groundwater level are simulated by changing the locations of injection and pumping well in seasonal cycle. However, in the second set of model the simulation is performed in the state of fixing the locations of pumping and injection well. After 365 days simulation period, the temperature distribution is dominated by injected water temperature and the distance from injection well. The small temperature change is appears on the surface compared to other slices of depth because the first layer has very low porosity and the transfer of thermal energy are sensitive at the porosity of each layer. The groundwater levels and temperature changes in injection and pumping wells are monitored to validate the effectiveness of the used heat pump operation method and the thermal interference between wells is analyzed.

  • PDF

비선형 Boussinesq방정식을 이용한 유로대수층 해석 (Analysis of stream-aquifer using nonlinear Boussinesq equation)

  • 정재성;김민환;방경미
    • 한국환경과학회지
    • /
    • 제11권1호
    • /
    • pp.57-61
    • /
    • 2002
  • To investigate the flow characteristics by the water stage variation between stream-aquifer, the new solution of nonlinear Boussinesq equation was derived and extended using the Boltzmann transformation. The soundness of the analytic solution obtained from this study was examined by the comparison with the linearized analytic solution and the numerical solution by finite difference method. And the movement, velocity, flowrate and volume of flow caused by the stage variation of stream and the existence of regional gradient were estimated. This new analytic solution can express the groundwater movement between stream-aquifer. So, it might be helpful to manage water environment.

지하수위 자료를 이용한 대수층의 수리상수 추정과 추정오차 분석 (Aquifer Parameter Identification and Estimation Error Analysis from Synthetic and Actual Hydraulic Head Data)

  • 현윤정;이강근;성익환
    • 지질공학
    • /
    • 제6권2호
    • /
    • pp.83-93
    • /
    • 1996
  • 최대우도법 (maximum likelihood method)을 이용하여 정류상태의 지하수위 자료로 부터 불균질성과 비등방성을 가지는 대수층의 수리상수를 추정하는 반전모델을 개발하였다. 반전모델을 이용하여 추정된 수리상수의 추정오차를 분석하기 위하여 Fisher information matrix 분석법을 도입하고, 수리상수의 추정을 위한 Parameterization의 방법으로 소유동영역화 방법 (zonation method)을 사용하였다. 개발된 반전모델을 이용하여 세가지 경우에 대해서 대구지역의 투수량계수를 추정하였다. 또한, 대구지역의 지하 수함양률을 각 소유동영역의 값으로 추정하였다. 각 추정에서 수반되는 추정오차의 특성을 Fisher information matrix를 구하여 사펴보았다.

  • PDF

PBM (Porous Body Model) 기반의 N-S Solver를 이용한 해안대수층의 해수침투모의 (Numerical Simulation on Seawater Intrusion in Coastal Aquifer using N-S Solver Based on Porous Body Model)

  • 이우동;정영한;허동수
    • 한국수자원학회논문집
    • /
    • 제48권12호
    • /
    • pp.1023-1035
    • /
    • 2015
  • 본 연구에서는 해수-담수-해안대수층의 비선형 상호작용을 직접 해석할 있는 PBM(Porous Body Model) 기반의 3차원 N-S Solver인 LES-WASS-3D ver 2.0을 적용하며, 해안대수층의 해수침투모의를 수행하였다. 이와 같은 N-S Solver를 적용한 해안대수층의 해수침투모의는 국내 최초 수행되는 것일 뿐만 아니라, 국외적으로도 찾아보기 어려운 새로운 수치해석방법이라고 할 수 있다. 먼저 적용하는 수치모델을 검증하기 위하여 해안대수층의 해수-담수 경계면에 관한 수리모형실험결과와 비교 검토하여 수치모델의 타당성 및 유효성을 확인하였다. 그리고 해수위 및 지하수위 변화를 고려한 해안대수층 내의 해수침투모의를 수행하여 해수위-지하수위 차와 해수위의 비(${\Delta}h/h$)의 증가에 따른 해안대수층 내의 유동장 그리고 해수-담수 경계면 분포 특성에 관하여 논의하였다. 또한 기존의 비확산 수치모델에서 도출할 수 없었던, ${\Delta}h/h$에 따른 해안대수층 내의 연직 염분농도로 부터 해수침투 특성을 파악하였으며, 최종적으로 지표화 할 수 있는 ${\Delta}h/h$가 해안대수층 내의 해수침투거리에 미치는 영향에 대하여 분석하였다. 이 결과로부터 ${\Delta}h/h$가 작을수록 해안대수층 내의 해수침투가 약해지는 메커니즘을 이해할 수 있었다.

대수층 이방성 분석을 위한 자연전위 모니터링의 적용 (Application of SP monitoring to the analysis of anisotropy of aquifer)

  • 송성호;용환호
    • 자원환경지질
    • /
    • 제36권1호
    • /
    • pp.49-58
    • /
    • 2003
  • 대수층의 수리적 이방성 분석을 위하여 시험정이 규칙적으로 배열된 두 곳의 실험현장에 대하여 양수시험 전후에 장기간의 자연전위 모니터링을 수행하였으며, 자연전위법 적용 이전 단계에서 지표 전기비저항탐사, 노말비저항검층 및 순간수위변화시험을 이용하여 대수층의 수리지질학적 구조를 파악하였다. 최근에 제안된 수치 모델을 이용하여 두 실험현장에 대한 자연전위 모니터링 자료를 해석한 결과 피압 대수층의 특성이 나타나며, 자연전위 자료로 등전위 분포도를 작성한 결과 다양한 방법에서 얻어진 대수층의 이방성 방향과 일치됨을 확인하였다. 따라서 이 연구에서 이용된 대수층시험과 자연전위 자료의 복합해석을 이용한 이방성 분석 기법 적용 결과는 관측정이 없는 단공양수시험 시대수층의 수평적인 이방성 등을 추정하는데 유용할 것으로 판단된다.

농촌 소유역에서 지하수 유동 모형의 매개변수 민감도 분석 (Sensitivity Analysis of the Groundwater Flow Model Parameters in a Small Rural Watershed)

  • 박기중;정상옥
    • 한국수자원학회논문집
    • /
    • 제37권8호
    • /
    • pp.687-693
    • /
    • 2004
  • 관측한 유역특성 자료와 지하수 유동 매개변수 값을 변화시키면서 MODFLOW 모형으로 시뮬레이션 한 결과를 비교ㆍ분석하였으며, 민감도 분석을 통하여 매개변수들의 상대적인 중요성을 파악하였다. 투수계수, 비산출율, 비저류계수, 대수층 두께 및 양수정 위치 등의 다양한 매개변수들에 대한 지속가능개발량 반응을 분석하였다. 매개변수에 대한 민감도 분석 결과, 하천에서 지하수체로 유입하는 량과 저류량은 비산출율과 대수층 두께에 민감하였으며, 지속가능개발량은 투수계수와 대수층 두께에 민감한 것으로 나타났다. 본 연구결과는 지역특성을 고려한 지하수 개발 및 관리계획 수립을 위한 기초자료로서 활용될 수 있을 것이다.

부산 도심지역 미고결층과 기반암의 수리지질 특성 (Hydrogeological Properties of Uunconsolidated Formations and Bedrocks in the Central Area of Busan Metropolitan City)

  • 함세영;차용훈;정재열
    • 지질공학
    • /
    • 제15권4호
    • /
    • pp.407-421
    • /
    • 2005
  • 본 연구는 부산광역시 도심지역 중 부산진구 양정동부터 동구 수정동까지 지역에 대한 수리지질 특성을 파악하였다. 이를 위하여 양정동의 암반대수층과 부산진구 부산진역 부근의 미 고결층에서 양수시험을 실시하였다. 특히 양정동의 암반대수층은 동래단층대와 만나는 지 역으로서 동래단층의 수리지 질 특성을 파악하는데 중점을 두었고, 부산진구 부산진역 부근의 미고결층에서 행한 양수시험에서는 해안매립지와 해안퇴적층(미고결층)의 수리지질 특성을 파악하였다. 양정동의 암반대수층에 대해서는 Moench의 구상체 이중공극모델이 적합한 것으로 나타났으며, 부산진역 부근의 미고결층에 대해서는 Neuman의 자유면대수층 모델이 적당한 것으로 나타났다. 암반대수층의 평균 투수량계수는 $2.75\times10^{-5}m^2/s$, 평균 저류계수는 $6.41{\times}10^-5}$이고, 미고결층의 투수량계수는 $8.24\times10^{-4}m^2/s$, 저류계수는 $3.70\times10^{-3}$이다. 한편 순간충격 시험에 의한 평균 투수량계수와 평균 저류계수는 각각 $9.84{\times}10^{-4}m^2/s\;와\;1.21{\times}10^-4}$이다.