• Title/Summary/Keyword: aqueous system

Search Result 1,124, Processing Time 0.03 seconds

Effect of Operating Parameters on Methyl Orange Removal in Catalytic Ozonation (촉매 오존화 공정에서 메틸오렌지 제거에 미치는 운전변수의 영향)

  • Lee, Myoung-Eun;Kim, Ji-Eun;Chung, Jae Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.7
    • /
    • pp.412-417
    • /
    • 2017
  • Removal characteristics of methyl orange and their dependence on operating parameters in a catalytic ozonation were investigated through a series of batch experiments. Activated carbon enhanced the self-decomposition of ozone, generating $OH{\cdot}$, thus promoting methyl orange degradation. As the carbon dose increases, the pseudo-first order rate constants of methyl orange degradation increased, resulting in the fast removal of methyl orange. The increase of gaseous ozone concentration enhanced the mass transfer to the aqueous solution, therefore, promoted the methyl orange removal. The methyl orange degradation was not significantly affected by the change of pH in the range of 5~12, and TOC removal was negligibly affected by the variation of pH over 7. The results indicate that the catalytic ozonation can be considered as an effective dye treatment technology.

A Hot Melt w/o/w Emulsion Technique Suitable for Improved Loading of Hydrophilic Drugs into Solid Lipid Nanoparticles (현탁된 고형지질나노입자 내로 친수성 약물의 봉입률을 증대시키기 위한 w/o/w 에멀션 가온용융유화법의 평가)

  • Lee, Byoung-Moo;Choi, Sung-Up;Lee, Jae-Hwi;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Recently increasing attention has been focused on solid lipid nanoparticles (SLN) as a parenteral drug carrier due to its numerous advantages that can come from both polymeric particle and fat emulsions, together with the possibility of controlled release and increasing drug stability. Lipophilic drugs such as paclitaxel, cyclosporin A, and all-trans retinoic acid have been successfully entrapped in SLN but the incorporation of hydrophilic drugs in SLN is very limited because of their very low affinity to the lipid. Therefore, as a new approach to improve the loading of hydrophilic drugs, a w/o/w emulsion technique has been developed. The primary objective of the current study was to improve the loading efficiency of a model hydrophilic drug, glycine (Log P = -3.44) into SLN. The proposed preparation process is as follows: A heated aqueous phase consisting of 0.1 ml of glycine solution in water (100 mg/ml), and poloxamer 188 (5 mg) were then added to a molten oil phase containing precirol (100 mg) and lecithin (5 mg). This mixture was dispersed by sonicator, leading to a w/o emulsion. A double emulsion (w/o/w) was formed after the addition of 2% poloxamer solution to the above dispersed system. After cooling the double emulsion, solid lipid nanosuspensions were successfully formed. The lipid nanoparticles had the mean particle size of 441.25 nm, and the average zeta potential of -20.98 mV. The drug loading efficiency was measured to be 8.54% and the drug loading amount was measured to be 0.92%. The w/o/w emulsion method showed an increased loading efficiency compared to conventional o/w emulsion method.

Pharmacoat Coating in an Aqueous System : The Dissolution Behavior and Reduction in Coating Time

  • Sekigawa Fujio;Muto Hiroaki;Araume Kiyoshi
    • Journal of Pharmaceutical Investigation
    • /
    • v.20 no.3
    • /
    • pp.51-76
    • /
    • 1990
  • It is sometimes said lately that the pH of the human gastric juice is significantly different among individuals. Thus, the dissolution behavior of coated solid dosage forms should preferably be independent of the pH of the test solution. With these points as a background, the effect of pH on the dissolution velocity of coated tablets was studied to compare that of Pharmacoat with other gastric soluble film coating materials. Three viscosity types of Pharmacoat have been available(3, 6 and 15cP) until now. the 6cP type has been considered to be the most suitable for a tablet coating amongst the three types. The 3 cP type with a low degree of polymerization, is capable of providing high concentration, but the film strength is so inferior that sometimes cracking of the film may occur. On the other hand, in the case of the 15cP type, high polymer concentration cannot be achieved because of the high dgree of polymerization, and thus it is uneconomical for coating. Now, there is a strong demand to reduce the coating time even when HPMC is used in the 6cP type in order to reduce the coating cost. In order to improve this problem, we have concentrated our attention on reducing the viscosity value of HPMC to an allowable lower limit from 6cP. As a result of this study, it was found that the reduction of the viscosity value to around 4.5cP enabled the use of a higher solution concentration and an incidental shorter coating time without giving any substantial adverse effects on the properties of coated preparations. These experiment results are presented in the later part of this presentation. Based on this study, we have added the viscosity type of 4.5cP as one of the Pharmacoat products as Pharmacoat-645.

  • PDF

Interfacial Features of Colloidal Particles in Aqueous Environment and Change in Its Stability According to Influential Conditions (수중 콜로이드성 고형물의 계면화학적 특성 및 영향 인자 조건에 따른 안정성의 변화)

  • Shin, Sung-Hye;Kim, Dong-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2227-2238
    • /
    • 2000
  • The interfacial features of suspension system made of $CaCO_3$ particles have been investigated for the purpose of designing its effective treatment process. For the examination of variation of electrokinetic potential as a function of pH. the value of potential was observed to shift in the negative direction, which was thought to be due to the adsorption of hydroxide ion on the particle surface. Adsorption of surfactant on suspended particles resulted in the change of surface charge and shift in electrokinetic potential, which was dependent upon the sign of head charge and concentration of surfactant. Addition of inorganic salts affected stability of suspension greatly and sedimentation rate of suspension was influenced by the electric valence and amount of ions produced by dissolution of inorganic coagulants. DLVO theory made it possible to construct a energy profile diagram and a close correlation was found between experimental result and theoretically derived consequences. Non-specific adsorption of indifferent electrolyte resulted in the compression of electrical double layer and specific adsorption induced the shift of IEP and PZC in the opposite direction.

  • PDF

Adsorption Behavior and Kinetic Characteristic of Cibacron Brilliant Red 3B-A by Granular Activated Carbon (입상활성탄에 의한 Cibacron Brilliant Red 3B-A의 흡착거동 및 동력학적 특성)

  • Lee, Jong Jib
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.486-491
    • /
    • 2014
  • In this paper, the adsorption behavior and kinetic characteristics of cibacron brilliant red 3B-A from aqueous solution using granular activated carbon were investigated. The effect of various parameters such as adsorbent dose, pH, initial concentration, contact time and temperature on the adsorption system were studied. Base on the estimated Langmuir constant ($R_L$) and Freundlich constant (1/n), This process could be employed as effective treatment method. From the Temkin constant (B) and Dubinin-Radushkevich constant (E), This adsorption process is physical adsorption. From kinetic experiments, the adsorption process followed the pseudo second order model with good correlation. Base on the Gibbs free energy and enthalpy, the adsorption of cibacron brilliant red 3B-A onto granular activated carbon was physisorption and endothermic in nature.

Simultaneous Determiniation of Ar/$N_2$Ratios in Groundwater (지하수에 용해된 질소, 아르곤 가스의 동시측정)

  • Kim, Euisik;Roy F. Spalding
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.6-9
    • /
    • 1994
  • Previously reported Ar/N$_2$ratios in groundwater have been measured by single ion monitoring (Barnes et al., 1975; Vogel et al., 1981; Mariotti et al., 1988). The detector geometry and flared flight tube in VG Optima isotopic ratio mass spectrometer appeared to be fortuitously aligned for the simultaneous measurement of Ar/N$_2$ratios. Method development included mechanical adjustments to optimize the mass spectrometer for Ar/N$_2$ratio measurements followed by development of a preparation system for the extraction of air-saturated water samples. Samples containing known Ar/N$_2$ratios were used to assess accuracy and precision, and to test the applicability of methods for measurements of aqueous Ar/N$_2$ratios. The results indicated that the prepared air-saturated water samples were almost identical to the predicted Ar/N$_2$ratios (p <0.001). Groundwater samples were collected from on-going research sites, Shelton and Grand Island, Nebraska. Samples from the Grand Island sludge injection site form a lower boundary for worldwide reported Ar/N$_2$ratios. These lower Ar/N$_2$ratios can be explained by the production of nitrogen gas from this site, where denitrification was reported previously.

  • PDF

Inorganic Printable Materials for Printed Electronics: TFT and Photovoltaic Application

  • Jeong, Seon-Ho;Lee, Byeong-Seok;Lee, Ji-Yun;Seo, Yeong-Hui;Kim, Ye-Na;More, Priyesh V.;Lee, Jae-Su;Jo, Ye-Jin;Choe, Yeong-Min;Ryu, Byeong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.1.1-1.1
    • /
    • 2011
  • Printed electronics based on the direct writing of solution processable functional materials have been of paramount interest and importance. In this talk, the synthesis of printable inorganic functional materials (conductors and semiconductors) for thin-film transistors (TFTs) and photovoltaic devices, device fabrication based on a printing technique, and specific characteristics of devices are presented. For printable conductor materials, Ag ink is designed to achieve the long-term dispersion stability and good adhesion property on a glass substrate, and Cu ink is sophisticatedly formulated to endow the oxidation stability in air and even aqueous solvent system. The both inks were successfully printed onto either polymer or glass substrate, exhibiting the superior conductivity comparable to that of bulk one. In addition, the organic thin-film transistor based on the printed metal source/drain electrode exhibits the electrical performance comparable to that of a transistor based on a vacuum deposited Au electrode. For printable amorphous oxide semiconductors (AOSs), I introduce the noble ways to resolve the critical problems, a high processing temperature above $400^{\circ}C$ and low mobility of AOSs annealed at a low temperature below $400^{\circ}C$. The dependency of TFT performances on the chemical structure of AOSs is compared and contrasted to clarify which factor should be considered to realize the low temperature annealed, high performance AOSs. For photovoltaic application, CI(G)S nanoparticle ink for solution processable high performance solar cells is presented. By overcoming the critical drawbacks of conventional solution processed CI(G)S absorber layers, the device quality dense CI(G)S layer is obtained, affording 7.3% efficiency CI(G)S photovoltaic device.

  • PDF

Mechanical Properties and Microstructure of the Leucite-Reinforced Glass-Ceramics for Dental CAD/CAM

  • Byeon, Seon-Mi;Song, Jae-Joo
    • Journal of dental hygiene science
    • /
    • v.18 no.1
    • /
    • pp.42-49
    • /
    • 2018
  • The computer-aided design/computer-aided manufacturing (CAD/CAM) system was introduced to shorten the production time of all-ceramic restorations and the number of patient visits. Among these types of ceramic for dental CAD/CAM, they have been processed into inlay, onlay, and crown shapes using leucite-reinforced glass-ceramics to improve strength. The purpose of this study was to observe the mechanical properties and microstructure of leucite-reinforced glass-ceramics for dental CAD/CAM. Two types of leucite-reinforced glass-ceramic blocks (IPS Empress CAD, Rosetta BM) were prepared with diameter of 13 mm and thickness of 1 mm. Biaxial flexural testing was conducted using a piston-on-three-ball method at a crosshead speed of 0.5 mm/min. Weibull statistics were used for the analysis of biaxial flexural strength. Fracture toughness was obtained using an indentation fracture method. Specimens were observed by field emission scanning electron microscopy to examine the microstructure of the leucite crystalline phase after acid etching with 0.5% hydrofluoric acid aqueous solution for 1 minute. The results of strength testing showed that IPS Empress CAD had a mean value of $158.1{\pm}8.6MPa$ and Rosetta BM of $172.3{\pm}8.3MPa$. The fracture toughness results showed that IPS Empress CAD had a mean value of $1.28{\pm}0.19MPa{\cdot}m^{1/2}$ and Rosetta BM of $1.38{\pm}0.12MPa{\cdot}m^{1/2}$. The Rosetta BM sample exhibited higher strength and fracture toughness. Moreover, the crystalline phase size and ratio were increased in the Rosetta BM sample. The above results are expected to elucidate the basic mechanical properties and crystal structure characteristics of IPS Empress CAD and Rosetta BM. Additionally, they will help develop leucite-reinforced glass-ceramic materials for CAD/CAM.

Fabrication of Transparent Dielectric Green Sheet for Plasma Display Panel (PDP 투명유전체 형성용 Green Sheet 제조)

  • Heo, Sung-Cheol;Park, Duck-Kyun;Oh, Young-Jei
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.4
    • /
    • pp.277-283
    • /
    • 2004
  • To fabricate green sheet of transparent dielectric for PDP front panel, dispersion of transparent dielectric slurry, density, and mechanical properties of green sheets have been investigated as a function of amount and composition of organic additives. Measurements of sedimentation and viscosity were employed to determine a proper dispersant and its amount for a well dispersed transparent dielectric powders in non-aqueous system. Green sheets, having various ratios of transparent dielectric powders to transparent dielectric powders+ binder+plasticizer and binder to binder+plasticizer, were fabricated. All the tape casting slurries showed shear thinning effect, that is, the apparent viscosity decreased with the increase of shear rate. It was found that the amount and composition of organic additives were main variables to affect densities and mechanical properties of transparent dielectric green sheets for PDP.

Characteristic of wastewater treatment using Boron-doped Diamond Electrode (붕소가 도핑된 다이아몬드전극을 이용한 폐수처리특성)

  • Lee, Eun-Ju;Einaga, Y.;Fujishima, A.;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.795-798
    • /
    • 2003
  • Toxic organics are of great environmental concern primarily because they are toxic to mammals and birds, and are relatively soluble in water to contaminate surface water and groundwater. In this study, the decomposition of phenol, a widely used organic, in aqueous solutions by Boron doped diamond(BDD) electrode was examined. Thin, Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped diamond (BDD) were used as anode for generating ozone gas by electrolysis of acid solution. In this work. we have studied ozone generating system using BDD electrode. In order to determine the ozone generation properties of diamond electrode, experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable for electrolyte while $PbO_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte. Decomposition of phenol concentration in the reaction solution by photolytic ozonation( $UV/O_3$) was analyzed by HPLC epuipped with a UV detector.

  • PDF